background image

 

TABLE OF CONTENT 

1-

 

SAFETY .......................................................... 3

 

1.1-

 

DANGER, WARNING AND CAUTION ................. 3

 

1.2-

 

IMPORTANT INFORMATION .............................. 3

 

1.3-

 

SAFETY RULES ................................................... 3

 

1.4-

 

FREEZING TEMPERATURES AND YOUR 

STRUCTURE .............................................................. 4

 

1.5-

 

INSTALLATION REGULATIONS ......................... 4

 

2-

 

INSTALLATION .............................................. 5

 

2.1-

 

LOCATION OF THE FURNACE ........................... 5

 

2.2-

 

VENTING .............................................................. 5

 

2.2.1-

 

General ........................................................................ 5

 

2.2.2-

 

Chimney installations ................................................. 5

 

2.2.3-

 

Side-wall venting ......................................................... 6

 

2.3-

 

AIR FOR COMBUSTION ...................................... 6

 

2.3.1-

 

General ........................................................................ 6

 

2.3.2-

 

Contaminated Combustion Air .................................. 6

 

2.3.3-

 

Ducted outdoor combustion air ................................. 7

 

2.4-

 

OIL TANKS AND LINES ...................................... 7

 

2.4.1-

 

BURNER INSTALLATION ........................................... 7

 

2.5-

 

BLOCKED VENT SHUT-OFF (BVSO) FOR 

CHIMNEY VENTING ................................................... 8

 

2.6-

 

INSTALLING ACCESSORIES ............................. 8

 

2.6.1-

 

Electronic air cleaner .................................................. 8

 

2.6.2-

 

Humidifier .................................................................... 8

 

2.6.3-

 

Air conditioning .......................................................... 8

 

2.6.4-

 

Ductwork and Filter .................................................... 8

 

3-

 

OPERATION ................................................. 10

 

3.1-

 

MANUAL OPERATION SWITCHES .................. 10

 

3.2-

 

SEQUENCE OF OPERATION ............................ 10

 

3.2.1-

 

Sequence of operation - Beckett AFII Side-wall 

venting   .....................................................................................10

 

3.2.2-

 

Sequence of operation - Riello 40-BF Side-wall 

venting   .....................................................................................10

 

3.2.3-

 

Sequence of operation - Beckett AFG and Riello 40-

F - Chimney venting .................................................................10

 

3.2.4-

 

Sequence of operation Side Wall Venting system ..10

 

3.3-

 

CHECKS AND ADJUSTMENTS ........................ 11

 

3.3.1-

 

General ....................................................................... 11

 

3.3.2-

 

Restart after burner failure ....................................... 11

 

3.3.3-

 

Combustion chamber curing .................................... 11

 

3.3.4-

 

Smoke / CO2 test ....................................................... 11

 

3.3.5-

 

Perform the supply air temperature rise test .......... 11

 

3.3.6-

 

Vent temperature test ................................................ 11

 

3.3.7-

 

Overfire pressure test procedure ............................. 11

 

3.3.8-

 

Fan-Limit adjustment ................................................ 12

 

3.3.9-

 

Limit control check .................................................... 12

 

3.3.10-

 

Side Wall Venting Blocked intake / blocked vent test 

 

 .................................................................................... 12

 

3.3.11-

 

BVSO performance test ............................................ 12

 

4-

 

MAINTENANCE ............................................ 13

 

4.1-

 

GENERAL .......................................................... 13

 

4.2-

 

INSPECTION POINTS ....................................... 13

 

4.2.1-

 

Heat exchanger .......................................................... 13

 

4.2.2-

 

Refractory firepot....................................................... 13

 

4.2.3-

 

Drawer assembly ....................................................... 14

 

4.2.4-

 

Nozzle ......................................................................... 14

 

4.2.5-

 

Oil filters ..................................................................... 14

 

4.2.6-

 

Air filters ..................................................................... 14

 

4.2.7-

 

Motor lubrication ....................................................... 14

 

4.2.8-

 

CAS-2B combustion air kit (chimney venting) ........ 14

 

4.2.9-

 

Blocked Vent Shut-Off (BVSO) Cleaning ................. 14

 

5-

 

TECHNICAL INFORMATIONS ..................... 15

 

 

TABLES 

Table 1: Minimum Installation clearances from combustible 
materials (Chimney installation*) ..................................................... 4

 

Table 2: Flue pipe diameter and minimum temperature .................. 6

 

Table 3: Technical specifications .................................................. 16

 

Table 4: Airflows; CFM with air filter .............................................. 16

 

Table 5: Parts list .......................................................................... 20

 

 

FIGURES 

Figure 1: Checking the polarity........................................................ 7

 

Figure 2: Controls .......................................................................... 10

 

Figure 3: Sight glass ..................................................................... 12

 

Figure 4: Limit control .................................................................... 12

 

Figure 5: Furnace Dimensions ...................................................... 17

 

Figure 6: Electrical Diagram, ODH53-F ......................................... 18

 

Figure 7: Parts List 

– Exploded view ............................................. 19

 

 

 

Содержание ODH53-F

Страница 1: ...MATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE UNIT FOR FUTURE REFERENCE HOMEOWNER PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE REFERENCE...

Страница 2: ...D ADJUSTMENTS 11 3 3 1 General 11 3 3 2 Restart after burner failure 11 3 3 3 Combustion chamber curing 11 3 3 4 Smoke CO2 test 11 3 3 5 Perform the supply air temperature rise test 11 3 3 6 Vent temp...

Страница 3: ...failure and cause dangerous operating conditions e Visually check all oil line joints for signs of leakage f Connect furnace to a side wall terminal or chimney g The points in Part 2 Operation are vi...

Страница 4: ...ossible Open faucets in appropriate areas b Have someone check the structure frequently during cold weather to make sure it is warm enough to prevent pipes from freezing Contact a qualified service ag...

Страница 5: ...ide wall power vent The unit will operate at a positive over fire draft and flue draft WARNING Poisonous carbon monoxide gas hazard Never vent this furnace together with another combustion appliance w...

Страница 6: ...C 300 F 179 C 355 F 221 C 430 F 41 140 000 1 00 0 1 m 4 0 15 m 6 107 C 225 F 149 C 300 F 185 C 365 F 221 C 430 F 51 175 000 1 25 0 1 m 4 0 15 m 6 116 C 240 F 135 C 275 F 160 C 320 F 185 C 365 F 2 3 AI...

Страница 7: ...vapour barrier Comprehensive installation instructions are provided with the kit 2 4 OIL TANKS AND LINES Check your local codes for the installation of the tank and accessories A manual shut off valv...

Страница 8: ...tructions supplied with the venting system 2 6 INSTALLING ACCESSORIES WARNING Electrical shock hazard Turn OFF electric power at fuse box or service panel before making any electrical connections and...

Страница 9: ...g Failure to properly seal duct can result in death personal injury and or property damage WARNING Poisonous carbon monoxide gas hazard Install evaporator coil on the supply side of the furnace ductin...

Страница 10: ...satisfied Also the solenoid valve remains open Thermostat is satisfied 8 Relay contacts open solenoid valve closes and the burner fan motor post purges the combustion chamber and vent for a pre set t...

Страница 11: ...after fabrication It is important to clear the chamber of this residue before testing If you smoke test before curing the instrument may become damaged To cure the chamber run the unit for 3 consecut...

Страница 12: ...efore a 1 smoke reading occurs 4 If the burner does not shut down before 1 smoke occurs ensure that the burner is set up according to Part 2 section 3 4 2 3 4 Perform the CO2 Smoke Test and allow for...

Страница 13: ...amic chambers they are easily damaged Soot will have collected in the first sections of the heat exchangers only if the burner was started after the combustion chamber was flooded with fuel oil or if...

Страница 14: ...should be replaced as required Secondary filter The 10 or less micron filter cartridges should be replaced annually 4 2 6 Air filters Air filters are the disposable type They should be replaced at lea...

Страница 15: ...Service telephone Day Night Dealer name and address START UP TEST RESULTS Nozzle Pressure lbpsi Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperatur...

Страница 16: ...only 3 1 5 3 3 3 4 5 AFUE From CSA B212 standard and Canadian regulation 81 5 81 0 80 3 AFUE From ASHRAE 103 standard and US regulation 81 5 81 0 80 3 RIELLO BURNER SIDE WALL INSTALLATION Burner tube...

Страница 17: ...17 Figure 5 Furnace Dimensions...

Страница 18: ...18 Figure 6 Electrical Diagram ODH53 F...

Страница 19: ...19 Figure 7 Parts List Exploded view B50030 Rev C...

Страница 20: ...tion B30773 30 Washer 3 8 AA zinc F06F005 31 Hexagonal nut 3 8 16NC brass F07F024 32 Sight glass Z99F061 33 Hexagonal flange nut 3 8 16NC brass F07O001 34A 5 breech plate B30459 34B 3 breech plate B30...

Отзывы: