background image

OWNER’S MANUAL

         

WARNING:

 If the information in these instructions 

is not followed exactly, a fire or explosion may result 

causing property damage, personal injury or loss of life.

 

-

 Do not store or use gasoline or other flammable vapors    

   and liquids in the vicinity of this or any other appliance. 

 

WHAT TO DO IF YOU SMELL GAS:

 Open all windows.

 Do not try to light any appliance.

 Do not touch any electrical switch; do not use  

  any phone or cell phone in your building.

 Extinguish any open flame.

 Immediately call your gas supplier from a neighbor’s 

  phone. Follow the gas supplier’s instructions.

 If you cannot reach the gas supplier, call the fire 

   department.

 Installation and service must be performed by a    

   qualified installer, service agency or the gas supplier.

25,000 - 35,000  

BTU/hr.

MONTEREY 

PLUS +

 HOME FURNACE  

TOP VENT GAS WALL HEATER

INSTALLATION INSTRUCTIONS

        WARNING: 

 Do not install any of these furnaces 

(natural or propane gas) in mobile/manufactured homes, 

trucks or recreational vehicles.

        WARNING:

 This product can expose you to 

chemicals including epichlorohydrin which is known to 

the State of California to cause cancer and birth defects 

and/or other reproductive harm. For information go to  

www.p65warnings.ca.gov

        WARNING:

 Improper installation, adjustment,  

alteration, service or maintenance can cause injury or 

property damage. Refer to this manual. For assistance or  

for additional information consult a qualified installer,  

service agency or the gas supplier.

SINGLE SIDED MODEL NUMBERS  

(natural gas)

2509822A / 3509822A

(propane gas)

2509821A / 3509821A

DOUBLE SIDED MODEL NUMBERS:

(natural gas)

5009822A

 

(propane gas)

5009821A

DISCONTINUED MODEL NUMBERS:

2519822 / 2559822 / 3519822 / 3539822 / 3559822 / 

5019822 / 6039822 / 5059822 / 3519821 / 3559821 / 

3519821 / 3539821 / 3559821 / 5019821 / 5039821 / 5059821

SAVE THIS MANUAL FOR FUTURE REFERENCE.

READ THIS OWNER’S MANUAL CAREFULLY BEFORE YOU 

INSTALL YOUR NEW WILLIAMS WALL FURNACE.

250 West Laurel Street, Colton CA 92324  •  WWW.WFC-FC.COM  •  1-888-444-1212  

50,000 BTU/hr.

TM

Содержание 2519822

Страница 1: ...urnaces natural or propane gas in mobile manufactured homes trucks or recreational vehicles WARNING This product can expose you to chemicals including epichlorohydrin which is known to the State of Ca...

Страница 2: ...IN THE PRODUCT OR ANY COMPONENT OR FROM THE USE THEREOF THE REMEDIES SET FORTH HEREIN ARE THE EXCLUSIVE REMEDIES AVAILABLE TO THE USER AND ARE IN LIEU OF ALL OTHER REMEDIES Some states do not allow li...

Страница 3: ...ALLING YOUR MOTORIZED REAR OUTLET PART NUMBERS FOR THE 250 350 MODELS CONTROL ASSEMBLY REPLACEMENT PARTS PART NUMBERS FOR THE 500 MODELS CONTROL ASSEMBLY REPLACEMENT PARTS 500 MODELS BLOWER ACCESSORY...

Страница 4: ...the appliance to avoid property damage bodily injury or death 8 Vent the furnace directly to the outdoors so that harmful gases will not collect inside the building Follow the venting instructions for...

Страница 5: ...dent of any installed system 1 Seal any unused openings in the venting system 2 Inspect the venting system for proper size and horizontal pitch as required in the National Fuel Gas Code ANSI Z223 1 NF...

Страница 6: ...ay New York NY 10018 In Canada CAN CGA B149 Optional Accessories Blower Accessories 2901 2907 May be used on all models and mounts on top of a furnace This blower increases circulation of warm air thr...

Страница 7: ...r cabinets 2 Check the minimum spacing needs as shown in Figure 1 3 The top of the furnace must be at least 16 inches from the ceiling 4 When the furnace is properly installed with legs resting on the...

Страница 8: ...etermined that each appliance connected to the venting system properly vents when tested as outlined above return doors windows exhaust fans fireplace dampers and any other gashed burning appliance to...

Страница 9: ...rt a fire and wait until flames are burning vigorously 2 Turn on all exhausting devices i e kitchen and bathroom exhaust fans water heaters gas and electric 3 Turn on all vented gas appliances i e hea...

Страница 10: ...t be provided from outdoors or spaces open to the outdoors such as an attic or crawl spaces Openings for inlet or outlet air should NOT be made into an attic area if the attic is equipped with a therm...

Страница 11: ...onal rear outlet register may be installed when the CHIMNEY OR GAS VENT VENTILATED ATTIC OUTLET AIR OUTLET AIR INLET AIR INLET AIR VENTILATED CRAWL SPACE 10 CRAWL SPACE WALL FURN TO ATTIC 12 OPTIONAL...

Страница 12: ...at this distance Figure 5 Place the header plate between the studs with the lower edges even with marks on the studs Make sure header plate is level Locate rear edge of nailing tabs at back of the he...

Страница 13: ...o the side rails using four 4 8 screws Flanges of the header plate go against the wall Figure A 3 Install extension side rails as shown in Figure A by telescoping them inside the lower side rails Adju...

Страница 14: ...C VENT INSTALLED FRONT PANEL INSTALLED STUD WALL CENTERED 14 3 1 2 STUD WALL GAS STUB LOCATIONS STUD WALL STUD WALL 16 4 7 16 A PLUMBERS TAPE B W VENT PIPING CEILING PLATE SPACER VENT HOLD DOWN PLATE...

Страница 15: ...t ceiling plate within the stud space through which the vent passes without any offsets or crossovers The first vent pipe offset if required may not be any closer than 2 feet from the header and needs...

Страница 16: ...RE 9 INSERT FURNACE FIGURE 10 NAIL PLACEMENT FIGURE 11 REMOVE KNOCKOUT PLATES REAR OUTLET KIT INSTALLATION OPTIONAL If a Rear Outlet Register Accessory is used the following procedure must be complete...

Страница 17: ...put to the burners must not exceed the rated input and pressure shown on the nameplate The natural gas manifold pressure should be 4 inches water column The manifold pressure should be 10 inches water...

Страница 18: ...as supply connection to the furnace GAS CONNECTION If the installation is for propane gas have the propane installer use a two stage regulator and make all the connections from the storage tank Use tw...

Страница 19: ...leak Correct even the slightest leak at once WARNING Danger of property damage bodily injury or death Never use a match or open flame to test for leaks Never exceed specified pressures for testing Hi...

Страница 20: ...allation instructions packed in the thermostat carton if you have any doubt about the above procedures WALL MOUNTED THERMOSTAT INSTALLATION 1 To remove the thermostat cover squeeze both sides and lift...

Страница 21: ...opening is provided in the gas valve to facilitate measuring manifold gas pressure A water column manometer having a scale range from 0 to 12 inches of water column should be used for this measurement...

Страница 22: ...lor to nearly invisible approximately 6 inches above ports ABNORMAL APPEARANCE LAZY FLAME Long soft yellow cones moving around in the combustion chamber lifting from ports insufficient air EXTREMELY F...

Страница 23: ...le 15 Set thermostat to desired setting TO TURN OFF GAS TO APPLIANCE 1 Set the thermostat to lowest setting 2 Turn off all electric power to the appliance if service is to be performed if applicable 3...

Страница 24: ...while actuating the red button or by using a match repeat steps 5 through 10 listed in Lighting the Pilot WARNING The surface of the furnace is hot during operation Keep children clothing furniture an...

Страница 25: ...joint union fitting Figure 24 4 Remove 2 screws securing burner pan assembly to inner liner 5 Pull burner pan assembly forward approximately 1 2 inch and drop down to expose the top of the burner 6 C...

Страница 26: ...out and remove it using a hammer and screwdriver Use caution when handling sharp metal edges 7 Place the blower body on furnace top as shown in Figure B 8 Route 115V wiring into the junction box throu...

Страница 27: ...MONTEREY PLUS TOP VENT GAS WALL HEATER 27 FIGURE C WIRING FOR MODEL 2901 FIGURE D WIRING FOR MODEL 2907...

Страница 28: ...before you cut any wall openings for the register 1 Measure and mark wall for opening as shown in Figure A Check the wall for any electrical wiring present before cutting the opening Reroute existing...

Страница 29: ...MONTEREY PLUS TOP VENT GAS WALL HEATER 29 FIGURE C SURFACED MOUNTED INSTALLATION FIGURE D SURFACED MOUNTED INSTALLATION FIGURE E SURFACE MOUNTED INSTALLATION FIGURE F WIRING...

Страница 30: ...26 P322055 P321826 P322055 8 Shield Assembly 9C213 9C213 9C213 9C213 9 Header 5902 5902 5902 5902 10 Burner Pan 9B296 9B296 9B296 9B296 11 Manual Spark Igniter P285500 P285500 P285500 P285500 12 Ignit...

Страница 31: ...MONTEREY PLUS TOP VENT GAS WALL HEATER 31 EXPLODED VIEW REPLACEMENT PARTS CHART 1 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 32: ...321836 A P321836 A 2 Valve P323011 P323011 P322660 P322660 3 Front Burner Bracket 9B234 9B234 9B234 9B234 4 Manifold P323660 P323660 P323660 P323660 5 Burner Orifice P332618 P332636 P332618 P332635 6...

Страница 33: ...MONTEREY PLUS TOP VENT GAS WALL HEATER 33 1 2 3 4 5 6 7 8...

Страница 34: ...imit Switch P321826 P321826 9 Draft Hood 2 Required 9C170 9C170 10 Non Vision Shield 9C157 9C157 11 Inner Shield Top 2 Required 9C158 9C158 12 Burner Pan Assembly 9B251 9B251 13 Blower Heat Deflector...

Страница 35: ...MONTEREY PLUS TOP VENT GAS WALL HEATER 35 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 6 EXPLODED VIEW REPLACEMENT PARTS CHART...

Страница 36: ...9A409 5009822 1 Wire Assembly Both Required P321836 A P321836 A 2 Valve P322660 P323011 3 Front Burner Bracket 9B243 9B243 4 Manifold P323661 P323661 5 Burner Orifice 2 P332623 P332625 6 Pilot Genera...

Страница 37: ...r Grille 9C99 3 Screw 8Ax 3 8 8 P093200 4 Screw 10 x P141000 5 Toggle Switch P320911A 6 Wire Bridle P320912 7 Flat Washer 10 31 2 P127300 8 Machine Nut 8 32 w Washer 2 P041100 9 Blower Body 9C102 10 M...

Страница 38: ...late 9B246 3 Wire Assemblies P323085 P323086 P323377 4 Blower and Motor P323423 5 Heat Sensor Wire Assemblies P274202 P109600 6 Junction Box Cover 9A483 7 Fan Switch P323080 8 Blower Body 9B249 9 Heat...

Страница 39: ...r 9A427 9A427 4 Strain Relief Bushing P603108 P603108 5 Heat Sensor Switch P323172 P323172 6 Fan Switch P323080 P323080 7 Motor and Blower P323423 P323423 8 Motor cover 9A435 9A462 9 Motor Housing Bac...

Страница 40: ...eading at generator terminals of the valve with the valve placed in Pilot position Disconnect the thermostat wires The millivolt reading should be 450 millivolts or more d Remove thermostat wires from...

Страница 41: ...our Furnace section in this manual b Check installation Casing may be distorted by being fastened to an uneven opening or jammed under the header A restricted vent may create expansion noise Refer to...

Страница 42: ...s always give the following Information 1 MODEL NUMBER 2 MFG DATE CODE 3 PART NUMBER 4 PART DESCRIPTION All parts listed herein may be ordered from your equipment supplier The Model Number of your Wil...

Страница 43: ...e service switch services both the appliance and the carbon monoxide detector b Have battery back up power c Meet ANSI UL 2034 Standards and comply with NFPA 720 2005 Edition and d Have been approved...

Страница 44: ...P323738_RV 03 21 www williamscomfortprod com 888 444 1212 250 West Laurel Street Colton CA 92324 USA Subject to change without notice 2021 TM...