background image

Содержание GRAVITY 1403611

Страница 1: ...formation consult a qualified installer service agency or the gas supplier WARNING Do not install any of these fur naces Natural or L R Gas in mobile homes trailers or recreational vehicles WARNING If...

Страница 2: ...DIRECTLY OR INOIRECT LY FROM ANY DEFECT IN THE PRODUCT OR ANY COMPONENT OR FROM THE USE THEREOE THE REMEDIES SET FORTH HEREIN ARE THE EXCLUSIVE REMEDIES AVAILABLE TO THE USER AND ARE IN LiEU OF ALL O...

Страница 3: ...2203621 2203622 3003621 and 3003622 are equipped with a wall thermostat Optional Accessories MODELS 1403611 1403612 1403621 1403622 For walls greater than 9 inches thick and up to 24 inches thick use...

Страница 4: ...UE TO HIGH TEMPERATURES locate the furnace out of traffic and away from furniture and draperies ALERT children and adults to the hazards of high sur face temperature and to keep away to avoid burns or...

Страница 5: ...r for bath tub use as most contain fillers and will not withstand high temperatures Pipe joint compound resistant to L IR Gases Electrical wiring supplies as needed for optional blower if equipped see...

Страница 6: ...a door or draperies Do not put in a closet alcove hallway or other confined space 7 Be sure that gas piping and electrical wiring optional blower only can be brought to the furnace See sec tions on g...

Страница 7: ...Use a stud Iocator or small finishing nails Repeatedly drive and remove a nail into the wall in the area of the stud until you find it Then find one side Leave the nail there Drive another nail just...

Страница 8: ...port legs using four 4 8 roundhead long screws F Fig 5 provided Push the air inlet shield J on from the exterior side of wall Rotate the air inlet shield until notches on the end of the tube are strad...

Страница 9: ...ion shown and fasten to inner cas ing through pre punched holes with screws C and D provided 3 Remove knock out G from bottom of junction box and install 115V line in accordance with local electrical...

Страница 10: ...st be of adequate size to handle the BTU HR requirements and length of the run for the unit being installed Determine the minimum pipe size from Fig 10 page 11 basing the length of the run from the ga...

Страница 11: ...CIFIED PRESSURES FOR TESTING HIGH PRESSURES MAY DAMAGE THE GAS VALVE AND CAUSE OVER FIRING WHICH MAY RESULT IN HEAT EX CHANGER FAILURE LIQUID PETROLEUM L P GAS IS HEAVIER THAN AIR AND IT WILL SE I FLE...

Страница 12: ...tat is being replaced and is in a satisfactory location and the wiring appears to be in good condition use existing wiring If in doubt use new wire 2 If a new location is chosen or if this is a new in...

Страница 13: ...termined under con tinuous operating conditions and was determined independently of any installed system Cabinet Installation MODELS 1403612 1403622 1403611 and 1403621 Set cabinet over furnace body d...

Страница 14: ...provided in the gas valve to facilitate measuring the manifold gas pressure A U Tube manometer having a scale range from 0 to 12 inches of water should be used for this measurement The manifold press...

Страница 15: ...ND OPERATING INSTRUCTIONS and use a match to light the pilot as instructed WARNING DANGER OF IGNITION FLASH AND EYE INJURY OR BLINDNESS PROTECT YOUR EYES NEVER ATTEMPT TO LIGHT PILOT WITH GAS CONTROL...

Страница 16: ...TOP 12 Follow B in the safety information above If you don t smell gas go to the next step 7 Loosen wlngnut and open pilot observation door if 13 equipped 14 8 Find pilot follow metal tube from gas co...

Страница 17: ...e 5 minutes to clear out any gas then smell for gas including near the floor If you then smell gas STOPI Follow B In the safety information above If you don t smell gas go to the next step 6 Loosen wl...

Страница 18: ...ll for gas including near the floor If you then smell gas STOP Follow B in the safety information above If you don t smell gas go to the next step 7 Loosen wingnut and open the pilot observation door...

Страница 19: ...KNOB SHOWN POSITION NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 6 Wait five 5 minutes to clear out any gas then smell for gas including near the floor I...

Страница 20: ...e about 10 minutes then look at the burner flame Flames should be soft and blue see Fig 27 If flames appear abnormal contact your gas company MAIN BURNER FLAME PATTERN 1111111111 Ill llll tlltl TOO MU...

Страница 21: ...of valve with pilot burning and thermostat contacts closed Should be 140 millivolts or more Remove thermostat lead wires from valve terminals If pilot now stays lit trace thermostat wiring circuit for...

Страница 22: ...d to back of control valve B Temperature dial out of See valve manufacturer s instruction calibration Bulb control model C Bulb or capillary broken Replace valve Bulb control model D Thermostat wiring...

Страница 23: ...NO 1 2 3 4 5 NOTE USE ONLY MANUFACTURE S AUTHORIZED PARTS 6 7 8 9 10 PART NO 6A24 6B33 P321017 P129700 6A23 P130600 6A93 P128400 P130700 6B64 DESCRIPTION SWITCH BRACKET SWITCH BOX SWITCH PULL CHAIN S...

Страница 24: ...CK WALL 8A85 FLUE EXTENSION MAX 9 THICK WALL BB64 MOUNTING SPACER PLATE P121800 AIR INLET GASKET VENT A FLUE EXTENSION 15 INCH WITH 1 P147001 GASKET EXTENSION KIT _ AIR INLET COLLAR 15 INCH WITH 1 P14...

Страница 25: ...Williams Direct Vent Gas Fired Wall Furnace REPLACEMENT PARTS FOR MODELS 1403611 140361 2 1403621 1403622 FOR PARTS lISTING SEE PAGE 24 USE ONLY MANUFACTURER S AUTHORIZED PARTS 25 1...

Страница 26: ...motor is noisy Housing rattling Blower dirty Blower wheel bent Reset thermostat to desired setting Check pilot Relight if necessary follow ing instructions for Operating Your Furnace If gas valve is...