background image

8

9

PT 

Series

3.0

 Operation

  

 Lighting the Heater 

 Shutdown

3.0

 Operation

WARNING

!

Improperly connected or damaged gas line may result in fire, explosion, 
poisonous fumes, toxic gases, asphyxiation, serious injury, or death. Check 
the hose assembly and gas connection before each use. Gas lines must be 
installed in accordance to national, state, provincial, and local codes.

Ignition flame may flash during lighting of the heater which may cause burns. 
Stand to the side of the heater, away from the burner during ignition.

The outside surfaces of the heater are hot during operation and after use. If 
contact is made permanent skin damage may occur. Do not move, handle, or 
service the unit during operation or while hot.

Lighting the Heater:

IMPORTANT!

 Inspect the heater before each use (refer to 

section 4.0 Maintenance). Operate on a stable, level surface. 
Do not knock or tip the heater over while in operation.

  Open LP gas cylinder (counterclockwise).  Figure 3.1.

  Check all gas connections for leaks using a soap and 

water solution. 

Do not use an open flame to check the 

connection.

  Light and place a match on the ceramic burner through the 

hole provided on side of reflector. 

Do not light the heater 

at the orifice or attempt to light with a spark lighter. 

Figure 3.2.

  Depress the brass button on the heater’s safety gas valve 

and continue to hold during ignition sequence. The heater 
should light within 10 seconds. Figure 3.3.

 

NOTE:

 If the heater does not light within 10 seconds, wait 

5 minutes before attempting to re-light.

  If lit, continue to depress the brass button for approximately 

30 seconds and then release.

  If the heater flame extinguishes, wait five minutes and 

repeat steps 1 through 5.

Shutdown:

  Close LP gas cylinder (clockwise).  Figure 3.4.

Figure 3.2

Light match, insert
through hole that 
is located on the 
lower side of the 
reflector.

Figure 3.3

Depress button,
ignite heater.

Figure 3.1

Turn handle, 
open gas valve.

Figure 3.4

Turn handle, 
close gas valve.

1

2

3

4

5

6

7

1 2

3

4 5

7

Содержание P-16T

Страница 1: ... and explosion hazard Keep combustibles such as building materials paper or cardboard a safe distance away from the heater as recommended by the instructions Never use the heater in spaces which do or may contain volatile or airborne combustibles or products such as gasoline solvents paint thinner dust particles or unknown chemicals This heater is not approved for use in any indoor residential app...

Страница 2: ...g Symbols 3 Applications 3 Clearance to Combustibles 4 Safety Signs and Labels 5 2 0 Installation 6 Installation 6 Heater Dimensions 7 Mounting the Heater 8 3 0 Operation 9 4 0 Maintenance 10 5 0 Parts 11 6 0 Repair 12 7 0 Limited Warranty 12 ...

Страница 3: ...ruction heaters is to provide temporary heating of buildings under construction alteration or repair It may also be used to provide temporary emergency heat This heater is not to be used in the home mobile homes campers tents recreational vehicles etc For maximum safety the building must be evaluated for potential hazards before locating and using the heater A critical safety factor to consider be...

Страница 4: ...locating the heater system Examples include but not limited to Gas and electrical lines Combustible and explosive materials Chemical storage areas Areas of high chemical fume concentrations Provisions for accessibility to the heater Combustion and ventilating air supply Vehicle parking areas Dirty contaminated environment WARNING Improperly connected gas line may result in serious injury or death ...

Страница 5: ...ce to Combustibles Model No Sides Back Top Front P 16T 18 18 48 48 P 32T 24 18 48 72 Side Top Front FRONT VIEW SIDE VIEW Safety Signs and Labels Safety warning labels must be maintained on the infrared heater Illustrations of the safety labels and their locations are pictured below Safety Label F N LLPCL001 Rating Plate BACK VIEW SAM PLE Side DETROIT RADIANT PRODUCTS COMPANY 21400 HOOVER ROAD WARR...

Страница 6: ...are approved for use with a DOT 20 lb LP gas cylinder with a 10 inch diameter base NOTE only use a vapor withdraw type cylinder Do not use a forklift truck or liquid dispensing cylinder See Chart 2 2 Operating Values for pressure specifications Along with maintaining the clearance to combustibles the heater must be used in a well ventilated area When the heater is temporarily used in an enclosed a...

Страница 7: ...Maximum Inlet Pressure PSI P 16T 16 000 LP 11 Inches W C 12 Inches W C 350 P 32T 32 000 LP 11 Inches W C 12 Inches W C 350 For purpose of adjustment The heater contained in this carton has been factory assembled and is in an operable condition without the need of adjustment or further assembly Only use the pressure regulator and hose LP only supplied with the heater Alteration of the heater or rep...

Страница 8: ...ockwise until it stops Do not use a wrench or over tighten Use only the hose and regulator assembly supplied with the heater Attach the mounting bracket to the flange of the cylinder and tighten the 3 8 16 thumbscrew until the mounting bracket is rigid Connect hose to the gas valve assembly Tighten clockwise with opposing wrenches to prevent damage to the gas valve assembly Check all gas connectio...

Страница 9: ...n operation Open LP gas cylinder counterclockwise Figure 3 1 Check all gas connections for leaks using a soap and water solution Do not use an open flame to check the connection Light and place a match on the ceramic burner through the hole provided on side of reflector Do not light the heater at the orifice or attempt to light with a spark lighter Figure 3 2 Depress the brass button on the heater...

Страница 10: ...place faulty valve Clean or replace orifice Heater lights flame extinguishes when releasing the brass button on the safety gas valve NOTE after depressing the button for one minute Inadequate gas pressure Insufficient fuel supply Thermocouple defective or loose Heater safety gas valve defective Check gas pressure See Chart 2 2 Provide adequate fuel supply Replace or tighten connection into valve R...

Страница 11: ...113A P 104 Rods for P 32T Qty 9 P 113A 90 flared tube fitting 3 8 O D X 1 8 FPT X 1 8 NPT P 105 Reflector assembly for P 16T P 114B Thermocouple w mounting clip for P 112B P 106 Reflector assembly for P 32T P 118 Cylinder mounting bracket P 107 Outer heater casing for P 16T P 119 Thumb screw with shoulder 3 8 16 Qty 2 P 108 Outer heater casing for P 32T P 123A 24 hose and regulator assembly w Type...

Страница 12: ...it Radiant Products for repair Repair cost is 48 00 for each P 16T model and 55 00 for each P 32T model Repair charges include return shipping and handling costs Units can be returned COD via UPS additional fees for COD service will apply Include a packing list with an explaination of the heater s symptoms The preferred method of payment is credit card Visa MasterCard or Discover Include a phone n...