background image

8

PT 

Series

2.0

 Installation

 

 Mounting the Heater

WARNING

!

Improperly connected gas lines may result in fire, explosion, 
poisonous fumes, toxic gases, asphyxiation, and death. 
Connect gas lines in accordance to national, state, and local 
codes.

Mounting the Heater  (P-16T, P-32T)

 Attach the mounting bracket to the heater by lining up the upper hole of the bracket with the mounting 

hole located on the side of the heater. Fasten the two parts with the 3/8-16 thumbscrew provided.

 Connect and hand tighten the included pressure regulator to the LP gas cylinder. Turn the nut 

(clockwise) until it stops. Do not use a wrench or over tighten. Use only the hose and regulator 
assembly supplied with the heater.

 Attach the mounting bracket to the flange of the cylinder and tighten the 3/8-16 thumbscrew until the 

mounting bracket is rigid.

  Connect hose to the gas valve assembly.  Tighten clockwise with opposing wrenches to prevent 

damage to the gas valve assembly. Check all gas connections for leaks using a soap and water 
solution. 

Do not use an open flame.

LP pressure regulator 
with hose.

Gas 
valve

LP gas cylinder
(not supplied)

Attach mounting 

bracket to LP 

cylinder.

Figure 2.2 

 Mounting: LP Gas Unit

Mounting 

hole

Mount bracket 

to heater.

Connect hose  to 

gas valve.

Connect pressure regulator 

to LP gas cylinder.

Lighting hole

Thumbscrew

1

2

3

4

1

2

3

4

Содержание P-16T

Страница 1: ... and explosion hazard Keep combustibles such as building materials paper or cardboard a safe distance away from the heater as recommended by the instructions Never use the heater in spaces which do or may contain volatile or airborne combustibles or products such as gasoline solvents paint thinner dust particles or unknown chemicals This heater is not approved for use in any indoor residential app...

Страница 2: ...g Symbols 3 Applications 3 Clearance to Combustibles 4 Safety Signs and Labels 5 2 0 Installation 6 Installation 6 Heater Dimensions 7 Mounting the Heater 8 3 0 Operation 9 4 0 Maintenance 10 5 0 Parts 11 6 0 Repair 12 7 0 Limited Warranty 12 ...

Страница 3: ...ruction heaters is to provide temporary heating of buildings under construction alteration or repair It may also be used to provide temporary emergency heat This heater is not to be used in the home mobile homes campers tents recreational vehicles etc For maximum safety the building must be evaluated for potential hazards before locating and using the heater A critical safety factor to consider be...

Страница 4: ...locating the heater system Examples include but not limited to Gas and electrical lines Combustible and explosive materials Chemical storage areas Areas of high chemical fume concentrations Provisions for accessibility to the heater Combustion and ventilating air supply Vehicle parking areas Dirty contaminated environment WARNING Improperly connected gas line may result in serious injury or death ...

Страница 5: ...ce to Combustibles Model No Sides Back Top Front P 16T 18 18 48 48 P 32T 24 18 48 72 Side Top Front FRONT VIEW SIDE VIEW Safety Signs and Labels Safety warning labels must be maintained on the infrared heater Illustrations of the safety labels and their locations are pictured below Safety Label F N LLPCL001 Rating Plate BACK VIEW SAM PLE Side DETROIT RADIANT PRODUCTS COMPANY 21400 HOOVER ROAD WARR...

Страница 6: ...are approved for use with a DOT 20 lb LP gas cylinder with a 10 inch diameter base NOTE only use a vapor withdraw type cylinder Do not use a forklift truck or liquid dispensing cylinder See Chart 2 2 Operating Values for pressure specifications Along with maintaining the clearance to combustibles the heater must be used in a well ventilated area When the heater is temporarily used in an enclosed a...

Страница 7: ...Maximum Inlet Pressure PSI P 16T 16 000 LP 11 Inches W C 12 Inches W C 350 P 32T 32 000 LP 11 Inches W C 12 Inches W C 350 For purpose of adjustment The heater contained in this carton has been factory assembled and is in an operable condition without the need of adjustment or further assembly Only use the pressure regulator and hose LP only supplied with the heater Alteration of the heater or rep...

Страница 8: ...ockwise until it stops Do not use a wrench or over tighten Use only the hose and regulator assembly supplied with the heater Attach the mounting bracket to the flange of the cylinder and tighten the 3 8 16 thumbscrew until the mounting bracket is rigid Connect hose to the gas valve assembly Tighten clockwise with opposing wrenches to prevent damage to the gas valve assembly Check all gas connectio...

Страница 9: ...n operation Open LP gas cylinder counterclockwise Figure 3 1 Check all gas connections for leaks using a soap and water solution Do not use an open flame to check the connection Light and place a match on the ceramic burner through the hole provided on side of reflector Do not light the heater at the orifice or attempt to light with a spark lighter Figure 3 2 Depress the brass button on the heater...

Страница 10: ...place faulty valve Clean or replace orifice Heater lights flame extinguishes when releasing the brass button on the safety gas valve NOTE after depressing the button for one minute Inadequate gas pressure Insufficient fuel supply Thermocouple defective or loose Heater safety gas valve defective Check gas pressure See Chart 2 2 Provide adequate fuel supply Replace or tighten connection into valve R...

Страница 11: ...113A P 104 Rods for P 32T Qty 9 P 113A 90 flared tube fitting 3 8 O D X 1 8 FPT X 1 8 NPT P 105 Reflector assembly for P 16T P 114B Thermocouple w mounting clip for P 112B P 106 Reflector assembly for P 32T P 118 Cylinder mounting bracket P 107 Outer heater casing for P 16T P 119 Thumb screw with shoulder 3 8 16 Qty 2 P 108 Outer heater casing for P 32T P 123A 24 hose and regulator assembly w Type...

Страница 12: ...it Radiant Products for repair Repair cost is 48 00 for each P 16T model and 55 00 for each P 32T model Repair charges include return shipping and handling costs Units can be returned COD via UPS additional fees for COD service will apply Include a packing list with an explaination of the heater s symptoms The preferred method of payment is credit card Visa MasterCard or Discover Include a phone n...