Manifold Pressure
Max. Inlet Pressure
Min. Inlet Pressure for
Purpose of Input Adjustment
Min. Mounting Angle
Max. Mounting Angle
Combustion Chamber
W.C.P.
W.C.P.
W.C.P.
5.0in.
14.0in.
3.5in.
0 DEGREES
45 DEGREES
4” BC Aluminized
120V
4.8
1.1
C1
VOLTS AC 60Hz
AMPS - Starting
AMPS - Running
Heater Type:
DESIGN COMPLIES WITH:
ANSI Z83.20b-2003-GAS FIRED LOW INTENSITY INFRA-RED HTR.
For Stainless Steel Upgrades the Combustion Table is upgraded to 409 Stainless Steel
Serial No. 0603DETR12345 0001
DETROIT RADIANT PRODUCTS CO.
21400 HOOVER ROAD - WARREN, MI 48089
(586) 756-0950 www.reverberray.com
AG1 - 40 - 125N
MODEL NO.
125,000
INPUT BTU/H
NAT GAS
FOR USE WITH
RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER
FOR INDOOR INSTALLATION ONLY
NEUTRAL
EARTH
HOT
- 120V HEATER INPUT -
120V
LS-20-40N
40,000
3
VALVE
PS
PRESSURE
SWITCH
V
1.0
Introduction •
Safety Signs and Labels
LS
Series
5
F/N: LLV3EP5
Green Crescent
(This label is on models with
optional 24VAO only).
Left Panel
(Fan Compartment)
F/N: LLV3EP6
SA
MP
LE
Top Panel
F/N: LLTCL006 - Clearance
to Combustibles Label.
F/N: LLLOGO1
Burner Control Box Component Label
(located under the top panel)
Bottom Panel
Gas Valve:
Circuit Board:
Wire Harness:
N.O. Switch:
N.O. VL Orifice:
N.C. Switch:
N.C. VL Orifice:
Diff Switch:
Diff VL Orifice:
Igniter:
Burner:
16” Tube:
Ind Lights:
Diag Light:
Term Block:
Transfomer:
Fan:
Alternate Fan:
Alt. Fan Usage:
IS22016051F5169 264E
36E96-224-N
Micro60-24
840
851
3 PCS Harness
852
None
N/A
None
None
N/A
None
Grey (+/-)
Norton
50
High
201
4” Stnd.
202
Yellow - 24V
828
Red LED
827
None
N/A
40VA
826
Fasco Lg.
55A
50Hz - 120V
55B
When Specified
BURNER COMPNENTS (Specify TP - #’s)
Your Heater is: C1
Orifice Type
Gas: TP204-#
Air: TP44-#
C1
C2
C3
3
3
1
1 1/2” 1 5/8” 1 5/8”
Relay:
Filter:
24 Volt In:
120 Volt In:
None
N/A
None
3T - plug
832
2x4 Box
Gas In:
Extra VL Orifice:
7/8” FC Flare
83
None
N/A
66
TUBE COMBINATION / KIT PARTS
Combustion:
Radiant:
Clamp:
Hangers:
RCS:
Reflector:
Endcap:
Baffle:
ID:
Electric:
Special 1:
Special 2:
Tag:
For Internal Use Only
TP-26A
TP-26A
TP-21B
TP-19B
TP-82
TP-20C
TP-105
TP-651 - 4”R
TP-26E
TP-26D
TP-21O
TP-19B-SS
TP-82-SS
TP-20C-SS
TP-105-SS
Item
Standard
Stainless Steel
Re-Verber-Ray
LLWT38
Micro60
Plug-Wh.
None
For all
Standard
Labels
See Board
Contact factory at 586-756-0950 for parts information and list prices. Or visit
http://wwwreverberray.com/parts
Data on this label is for the model shown on this label. If your heater has been
converted, this information is not correct. Please contact the factory for assistance.
LS-20-40N
Production Code: LS-40
Version: 5/05
0603DETR12345 0001
Serial #:
N/A
Stock:
None
Add-On Option(s):
LS
LS
SA
MP
LE
Back Panel
Rating Plate
F/N: LLTB018 (NG)
F/N:
LLTB019 (LPG)
Air Metering Orifice
DO NOT REMOVE
TP-114
TP-3014
1 - 1/2"
F/N: LLAC
Air Metering Orifice
SAMPLE
Manifold Pressure
Max. Inlet Pressure
Min. Inlet Pressure for
Purpose of Input Adjustment
Min. Mounting Angle
Max. Mounting Angle
Combustion Chamber
W.C.P.
W.C.P.
W.C.P.
5.0in.
14.0in.
3.5in.
0 DEGREES
45 DEGREES
4” BC Aluminized
120V
4.8
1.1
C1
VOLTS AC 60Hz
AMPS - Starting
AMPS - Running
Heater Type:
DESIGN COMPLIES WITH:
ANS Z83.20b-2003-GAS FIRED LOW INTENSITY INFRA-RED HTR.
For Stainless Steel Upgrades the Combustion Table is upgraded to 409 Stainless Steel
Serial No. 0603DETR12345 0001
DETROIT RADIANT PRODUCTS CO.
21400 HOOVER ROAD - WARREN, MI 48089
(586) 756-0950 www.reverberray.com
LS - 20 - 40N
MODEL NO.
40,000
INPUT BTU/H
NAT GAS
FOR USE WITH
RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER
FOR INDOOR INSTALLATION ONLY
LS
NEUTRAL
EARTH
HOT
- 120V HEATER INPUT -
120V
F/N: LLV3EP1