![Detroit Diesel EPA04 MBE 900 Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/detroit-diesel/epa04-mbe-900/epa04-mbe-900_operators-manual_2488037047.webp)
MBE 900 OPERATOR'S MANUAL
Emergency Running Mode
The engine is equipped with the
electronic engine control system,
which monitors the engine as it is
running.
As soon as a fault is detected, it is
evaluated and one of the following
measures is initiated.
NOTICE:
To prevent possible serious engine
damage, have any faults corrected
without delay by an authorized
dealer.
□
In conjunction with the
instrumentation control unit
(ICU), the code for the electronic
control unit reporting the fault
can be read immediately on the
display.
□
Complete fault codes are
transmitted and can be read using
ServiceLink at any authorized
dealer.
□
If the fault is serious enough to
impair normal operation, the
electronic engine system switches
over to emergency running mode.
When in emergency running
mode, the engine operates at a
constant 1300 rpm. This allows
you to move the vehicle to a
service location.
Stop Engine Override
Option
The Stop Engine Override Option is
used for a momentary override. The
DDEC-ECU will record the number
of times the override is activated after
a fault occurs.
Momentary Override
– A Stop
Engine Override (SEO) switch
is used to override the shutdown
sequence (see Figure 26). This
override resets the 60 second (30
seconds for oil pressure) shutdown
timer, restoring power to the level
when the Red Stop Lamp (RSL) was
illuminated. The switch must be
recycled after
fi
ve seconds to obtain a
subsequent override.
Figure 26 Typical SEO Switch and
Warning Lamps
NOTE:
The operator has the responsibility to
take action to avoid engine damage.
All information subject to change without notice.
(Rev. )
37
DDC-SVC-MAN-0055
Copyright © 2009 DETROIT DIESEL CORPORATION
Содержание EPA04 MBE 900
Страница 2: ......