background image

OPERATIONS

SPECIAL NOTES and DEFINITIONS:

1. The door needs to be closed to test the unit.

2. When operating the ON/OFF switch, there is a slight delay.

3. The key is inserted and removed only in the vertical position (home position).

4. Key function: counter clockwise (CCW) = Armed; clockwise (CW) = Disarmed

5. The door prop function is selectable by setting SWITCH A to the OFF position.

    For door chime function, set SWITCH A to the ON position

MAGNET HANDING PROCEDURE:

 Magnet handing is where the device determines if the left,

right or an external reed switch will be used to indicate if the door is opened or closed. When the

battery is initially installed, the device simultaneously flashes the LEDs and chirps the siren a total

of five times. This indicates that the device is in the magnet handing process:

  Step 1: If re-handing is necessary, remove the unit from the door, momentarily short the

              REHANDING (or

Test) 

jumper contacts.  The device simultaneously flashes the LEDs and

              chirps the siren a total of five times.

  Step 2: Turn the key CW to the 'OFF' position.

  Step 3: Install the device on the door.

  Step 4: With the door open, turn the key CCW to the 'ON' position. The red LED blinks twice.

  Step 5: Close the door and bring the external magnet into position with the external door switch.

               The siren chirps and the LED flashes on the selected side of the device (red LED flashes for

               the left side or external; green LED flashes for right side).

The device will now operate normally, and the selected reed switch side is stored in memory so

changing the battery does not require re-handing.

DOOR PROP OPERATIONS:

 The door prop function is selected by setting SWITCH A to the 'OFF'

position. To arm the system, close the door and turn the key CCW to the 'ON'

position. The red LED will flash twice indicating that the device is now armed. If the door is opened,

the device will begin a timing countdown according to the selected amount of time (15 seconds default).

If the 

Status Indicator

 (switch B) is 'ON', the red LED will blink every second during the countdown. If the door is not closed

before the door prop time runs out, the alarm sounds and the red LED flashes. Closing the door will silence the alarm and

rearm the unit. To change the door prop timing, see the section 

Changing Door Prop Timing

.

DOOR CHIME OPERATIONS:

 

 The door chime function is selected by setting SWITCH A to the 'ON' position.

To arm the system, close the door and turn the key CCW to the 'ON' position. The red LED will flash twice indicating

that the device is now armed.  If the door is opened, the device sounds a series of siren chirps lasting

five seconds. No other action is taken until the door is closed and the unit rearms.

DISARMING:

 To turn off the alarm or disarm the system, turn the key CW to the 2 o'clock position.

TROUBLESHOOTING: If the unit does not arm, the magnet may need to be re-aligned or shimmed closer to

the EAX-300. If the unit fails to operate correctly, restart the device by removing the battery for approximately

five seconds.

LOW BATTERY ALERT:

 Simultaneous siren chirps and red LED flashes occur at 45 second intervals when

battery reaches approximately 7 volts. The 

LV Opt

 jumper must be in place to use this feature (default).

STATUS INDICATOR: 

With the Status indicator (SWITCH B) 'ON': red LED flashes every six seconds

when armed; green LED flashes every six seconds when disarmed.

"ON"

position

"OFF"

position

"ON"

position

Key orientation

without

 Key Stop

installed

Key orientation

with

 Key Stop

installed

"OFF"

position

ON

OFF

ON

OFF

ON

OFF

ON

OFF

REHANDING

(or

Test)

 jumper

contacts.

LV Opt jumper

behind cover

(under SWITCH A)

104889  Page 6

Содержание EAX-300

Страница 1: ......

Страница 2: ...nctions STATUS INDICATOR SWITCH B OFF No indication that device is armed or disarmed ON DP SWITCH A OFF Door chime mode ON Door prop mode Default settings Will shorten battery life ARMED red LED blinks approximately every 6 seconds DISARMED green LED blinks approximately every 6 seconds STATUS INDICATOR OFF A AR B DP NOTE For Key Stop See Step 9 1 Install mortise cylinder with cylinder nut provide...

Страница 3: ... mounting holes Backplate Drill 7 for 1 4 20 machine screws Drill 7 32 or 3 16 for 14 sheetmetal screws Magnet Drill 43 for 4 40 machine screws Drill 44 for 4 sheetmetal screws Backplate Drill 7 for 1 4 20 machine screws Drill 7 32 or 3 16 for 14 sheetmetal screws Mark drill backplate and magnet holes on door and frame mullion Install magnet with 2 4 40 or 4 screws Install backplate with 2 1 4 20 ...

Страница 4: ...ailable for SK installations Closed contact when door is closed NOTES 1 If wire runs longer than 10 feet must use twisted pair 2 1 16 slotted jeweler screwdriver required 3 If internal contact is used DO NOT cut jumper JP1 Disconnect power cut JP1 jumper see note 3 below STEP 7 Multi door SK function wiring connection if required Recommended installation 7a 7b 7c 7d Screw wires to P1 terminal bloc...

Страница 5: ...NS STEP 9 KEY STOP INSTALLATION Key stop included in hardware kit Top surface of Key Stop should NOT protrude beyond highest point on plastic cam Install key stop P N 102688 Cam orientation for Key Stop option Key and cams shown in OFF position Key and cams shown in 90 stop ON position STEP 8 INSTALL DEVICE Install device onto backplate Turn key CW to lock cover Hook at bottom then tilt cover over...

Страница 6: ...oor and turn the key CCW to the ON position The red LED will flash twice indicating that the device is now armed If the door is opened the device will begin a timing countdown according to the selected amount of time 15 seconds default If the Status Indicator switch B is ON the red LED will blink every second during the countdown If the door is not closed before the door prop time runs out the ala...

Страница 7: ......

Страница 8: ...or external magnet Weatherized device PROBABLE CAUSE The device is setup as Door Chime PROBABLE CAUSE The device is setup as Door Prop ACTION 1 Remove battery and firmly reinstall 1 Use magnet locator to install magnet See magnet handing 2 Replace battery 3 Requires standard Yale cam 4 Microswitch needs to be replaced Remove PCB and return to Detex Repair 5 Check cylinder installation Make sure ke...

Отзывы: