background image

1-1/2

Flex walls outward to remove guard

& board

1"

Drill 7/8 dia

(1) place

Recommended hole size

Common

Terminal

P/N: PP-5107

Closed

Mag

Switch 1

Switch 2

Mag

Diagram shown typical for two door magnetic switches:

MS-1039S & MS-1059S wire in series.

MS-2049 (Red wire not used)

Weatherized not available for SK installations

Closed contact when door is closed

NOTES:

1. If wire runs longer than

  10 feet, must use twisted pair

2. 1/16" slotted jeweler

   screwdriver required.

3. If internal contact is used

   DO NOT cut jumper (JP1)

Disconnect power &

cut (JP1) jumper

(see note 3 below)

STEP 7: Multi-door & SK function wiring connection 

(if required)

(Recommended installation)

7a

7b

7c

7d

Screw wires to (P1) terminal block

(18ga Max wire dia)

Reassembly:

Fitting or nut NOT included

Common

Closed

104889  Page 4

Содержание EAX-300

Страница 1: ......

Страница 2: ...nctions STATUS INDICATOR SWITCH B OFF No indication that device is armed or disarmed ON DP SWITCH A OFF Door chime mode ON Door prop mode Default settings Will shorten battery life ARMED red LED blinks approximately every 6 seconds DISARMED green LED blinks approximately every 6 seconds STATUS INDICATOR OFF A AR B DP NOTE For Key Stop See Step 9 1 Install mortise cylinder with cylinder nut provide...

Страница 3: ... mounting holes Backplate Drill 7 for 1 4 20 machine screws Drill 7 32 or 3 16 for 14 sheetmetal screws Magnet Drill 43 for 4 40 machine screws Drill 44 for 4 sheetmetal screws Backplate Drill 7 for 1 4 20 machine screws Drill 7 32 or 3 16 for 14 sheetmetal screws Mark drill backplate and magnet holes on door and frame mullion Install magnet with 2 4 40 or 4 screws Install backplate with 2 1 4 20 ...

Страница 4: ...ailable for SK installations Closed contact when door is closed NOTES 1 If wire runs longer than 10 feet must use twisted pair 2 1 16 slotted jeweler screwdriver required 3 If internal contact is used DO NOT cut jumper JP1 Disconnect power cut JP1 jumper see note 3 below STEP 7 Multi door SK function wiring connection if required Recommended installation 7a 7b 7c 7d Screw wires to P1 terminal bloc...

Страница 5: ...NS STEP 9 KEY STOP INSTALLATION Key stop included in hardware kit Top surface of Key Stop should NOT protrude beyond highest point on plastic cam Install key stop P N 102688 Cam orientation for Key Stop option Key and cams shown in OFF position Key and cams shown in 90 stop ON position STEP 8 INSTALL DEVICE Install device onto backplate Turn key CW to lock cover Hook at bottom then tilt cover over...

Страница 6: ...oor and turn the key CCW to the ON position The red LED will flash twice indicating that the device is now armed If the door is opened the device will begin a timing countdown according to the selected amount of time 15 seconds default If the Status Indicator switch B is ON the red LED will blink every second during the countdown If the door is not closed before the door prop time runs out the ala...

Страница 7: ......

Страница 8: ...or external magnet Weatherized device PROBABLE CAUSE The device is setup as Door Chime PROBABLE CAUSE The device is setup as Door Prop ACTION 1 Remove battery and firmly reinstall 1 Use magnet locator to install magnet See magnet handing 2 Replace battery 3 Requires standard Yale cam 4 Microswitch needs to be replaced Remove PCB and return to Detex Repair 5 Check cylinder installation Make sure ke...