17
service menu
1.1. UV [*]
Allow the user to adjust the sensitivity of the UV detection function.
UV-0 is OFF / UV-9 is Highest / UV-3 default
1.2. MG1 [*]
Allow the user to adjust the sensitivity of the MG detection function.
MG-0 is OFF / MG-9 is Highest / MG-1 default
1.3. Stacker Capacity
Allow the user to adjust the value by using the Up and Down arrows.
Default setting is set at 200 notes. Maximum stacker capacity of 200 notes.
1.4. Printers Baud Rate Set
Allow the user to match the thermal printer communication. The baud rate can
change based on the printer which connects to the machine. We set to value=3 if the
baud rate is 9600, otherwise set to other values that matches with your printer baud
rate.
1.5. Width [*]
Allow the user to adjust the sensitivity of the DD detection function (Width Size).
DD-0 is OFF / DD-9 is Highest / DD-4 default
1.6. Reject Capacity
Allow the user to adjust the value by using the Up and Down arrows.
Default setting is set at 50 notes. Maximum capacity of 100notes in the Reject Pocket.
1.7. Double [*]
Allow the user to adjust the sensitivity of the DB detection function (Double Bill).
DB-0 is OFF / DB-9 is Highest / DB-5 default
1.8. Half an Alarm Count
Allow the user to count a ripped note as 1pcs or 0 pc. Set 0 as default, otherwise it will
count 1pc.
1.9. Start Sensor Threshold [*]
Allow the user to adjust the Start Sensor Sensitivity in Auto Count when the notes
color are too dark. higher values increase the sensitivity of the sensor.
1.10. IR Sensitivity [*]
Allow the user to adjust the sensitivity of the IR detection function.
IR-0 is OFF / IR-9 is Highest / IR-1 default
1.11. Backlight Time
Allow the user to set the backlight time of the display screen when the machine is idle.
1.12. Clear Sensor Threshold [*]
Allow the user to clear the data from the last count. When notes are removed from
the stacker post each count, the machine display will clear-zero. If the machine doesn’t
clear the last count display, please contact support team to advice on increasing the
sensitivity or otherwise replace the sensor
1.13. Alarm Counting Selection
This function is not applicable
1.14. SN Serial Number Switch
Allow the user to adjust the SN by using the Up and Down arrows. SN is turned ON
when Value=1 and turned off when Value=0
1.15. Brake Sensitivity [*]
Allow the user to adjust the sensitivity of brakes i.e. fast or slow break
1.16. Beeper Setup
Allow the user to adjust the value by using the Up and Down arrows. The beeper is
switch off when Value=1 and incrementally increases up to value=4.