background image

A

A

INSTRUCTION MANUAL

3

Due to the very high intensity of the signal while operating the detector with the 1mX1m 
coil or the bigger sized coils, you would not be able to get an idea about the location of 
the target and you would have difficulties with its pin-pointing. At the moment you start 
hearing a signal from the target press immediately the RESET button, but in no way 
while the signal from the target has reached its maximum strength. In this way you’ll be 
able to pin-point the target much better. After the resetting, passing over the target you’ll 
hear signal with much less intensity (see the right display above) and the pin-pointing will 
be much more accurate. We recommend this only to the experienced operators, as there 
is a risk to reject a target if resetting the detector in inappropriate moment.  
The bigger size of the target, and the closer distance to it, the higher is the intensity of 
the signal. When the signal’s intensity is maximal, the graphics will raise to the highest 
part of the operative screen, and a value of 100 will be given in the middle of the screen.
If the signal is with a lower intensity (this could happen while resetting, as explained 
above) the graphics will reach a lower level, and the value on the screen will be, as in 
the described example, 48.
Note: If you are moving the coil correctly, at a constant operational height, not passing 
over metal object, and you are not under the influence of strong electromagnetic 
disturbances, the graphics will be a smooth straight line “crawling” in the lower end of the 
screen, and the intensity of the signal will be 0.

NOTE: While in Automatic Mode the SSP-5100 is a typical motion system - the search 
coil should be moved slowly over the ground surface, but never stop over a metal target. 

Try to keep constant operational height of the coil. If anyway you change the 

operational height of the search coil, nearing it sharply to the ground surface, the 
processor will need 7-8 seconds to restore the optimum ticking rate. If you don’t want to 
wait for this, you could use whichever of the two RESET buttons for a fast AUTO 
retuning.

NOTE: If you RESET while the coil is passing over a metal target the detector will tune 
to the target and it will be cancelled, or will produce only a very faint signal.

Some professionals use this feature to decrease the signal’s intensity and receive a 
better target pin-pointing. If you have a big shallow target the signal’s line would be like 
that on the screen shown left down.

100

48

Содержание SSP-5100 G

Страница 1: ...SSP 5100 G...

Страница 2: ...dle sector A magnetometer is built in there making possible the unique discrimination of your detector Now join all the tubing elements as shown on Figure 1 After the assembly position the coil on ope...

Страница 3: ...the loudspeaker of the detector Your detector is now ready for searching ATTENTION If you are close to metal object the cursor will continue to move from max to min positions unable to stop at a cert...

Страница 4: ...while resetting as explained above the graphics will reach a lower level and the value on the screen will be as in the described example 48 Note If you are moving the coil correctly at a constant oper...

Страница 5: ...ton On the Operative Screen the symbol A for Automatic Mode will change to the symbol M Manual Mode of operation Then you should press the TUNER button so that you could tune the detector in the Manua...

Страница 6: ...f the detector No matter whether you have increased or decreased the ticking rate you ll have to press the DETECT button Immediately upon this the processor will save the setting of the ticking rate y...

Страница 7: ...ding the unnecessary digging of the unwanted shallow ferrous targets The detector is set in a way to discriminate only in the surface arable layer of the ground As it happens often the hoards of coins...

Страница 8: ...work with headphones then he could be forced to decrease the sound s volume this could be made by pressing the VOLUME button in front of this button on the operative screen is inscribed the current le...

Страница 9: ...r operation in heavily mineralized grounds Mind that with the MAX setting of the DELAY the detector loses a little bid of its sensitivity With every change of the DELAY settings on the display will ap...

Страница 10: ...o the wall socket The detector starts charging But to be able to see the process press ON OFF button If the battery is not charged on the screen will appear a text BATTERY CHARGING BATTERY HAS BEEN CH...

Страница 11: ...stant operational height of the searchcoil and you do not pass over a metal object Note that the intensity of the signal is 0 When you operate the detector in areas with electromagnetic interferences...

Страница 12: ...rous target Small shallow low magnetic ferrous target Small shallow strongly magnetized ferrous target With the graphics above we have shown only some more typical cases In the practice the graphical...

Страница 13: ...ng Frequency 100 Hz Sound Range 0 2Hz 2 0KHz Battery Rechargeable 1800mA 12V Charger Input 110V AC 60Hz Charger Output 17V DC Battery Charging Time empty max 10 hours Depth Control for Maximized Detec...

Страница 14: ......

Отзывы: