Wiring 

 

 
Standard Fans 
The standard fan can be connected to the lighting circuit and controlled 
from a switch so that it only operates when the switch is on.  The fan must 
be fed by a DP switched connection unit fitted with a 3A fuse.  See Fig. 1. 
 
The connections for this fan are: 
 

L     permanent live 

 

N     neutral 

 
 
Timer Fans and Timer and Humidistat Fans 
The timer fan can be connected to the lighting circuit.  The circuit for this 
fan must be protected by a 3A device and should be controlled by a 3 pole 
fan isolator.  See Fig. 2. 
 
The connections for this fan are: 
 

L     permanent live 

 

S     switch live 

 

N     neutral 

 
 
Low Voltage Fans 
The Low Voltage ventilation fan can be installed in zone 1 in a bathroom or 
shower room, however the supply transformer must be installed outside 
zone 2 (see Special Installations or Locations Particular Requirements in 
the current edition of the IEE Wiring Regulations, BS 7671).  The 
transformer requires a 240V supply, and has an ELV output to the fan. 
 
 
Shower Fan Kits 
In-line fans in the shower fan kit are mains voltage and wiring is identical 
to timer fan, see Fig. 2.  The 12V light in the shower kit is low voltage and is 
fed by the voltage transformer which is wired independently from the 
ceiling rose/junction box. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Control Adjustments 

 

 
The timer and humidistat and timer fans are supplied with an insulated 
screwdriver for adjusting the controls, which is clipped to the fan body. 
 
 
Timer 
The timer is adjustable from approximately 2 minutes to 30 minutes.  The 
timer is factory set at approximately 15 minutes.  Turn the control 
clockwise to increase the on time.  Timers should be set for 15 minutes 
minimum. 
 
 
Humidistat 
The humidistat range is approximately 60 – 90% relative humidity.  The 
humidistat is factory set at approximately 75%.  Turn the control clockwise 
to increase humidity  
 
 
 

 

 
 
Specification 

Voltage 

220 – 250V ac  50Hz 

Extraction Rate 4” 

90m

3

/hr ( 25 ltr/sec) 

Compliance 

BS EN 60335-1 and EN 62233 

Extraction Rate 6” 

255m

3

/hr ( 71 ltr/sec) 

Hole cutout dimensions 

4” fan 

Ø 110mm hole max. 

Extraction Rate 4” Low Voltage 

85m

3

/hr ( 24 ltr/sec) 

 

6” fan 

Ø 155mm hole max. 

Extraction Rate 4” Flat Fascia 

92m

3

/hr ( 26 ltr/sec) 

Timer Adjustment 

2 – 30 minutes 

Extraction Rate 4” Shower Fan 

107m

3

/hr ( 30 ltr/sec) 

Humidistat Adjustment 

60 – 90% humidity 

IP Rating 

IP 24 (Shower Fan IP X4) 

 
 
 

 
NPD 0452 12/2015 V2 