EN
Service
08/2020
21 / 28
Lubricate with the required grease or oil. Do not apply too much grease on gears or bearings; a thin coat shall be
sufficient.
Preventive Maintenance
Recommendations
Overhaul and preventive maintenance are recommended at regular intervals once per year or after a maximum num-
ber of tightenings (refer to the table below) depending on which occurs sooner.
Maintenance frequency
500,000 tightenings
Calibration with eDOCK and CVIMONITOR
The calibration procedure is recommended to compensate for any possible drift of the tool torque or after any change
of tool element.
In the manual mode, the standard procedure is executed.
Measurements and values are typed manually by the operator.
The equipment required is as follows:
• Tool equipped with a torque transducer in line
• CVIMONITOR
• Delta measuring unit
Click this icon.
Click
Tool calibration
.
The standard procedure is as follows:
1.
Select the Pset to execute.
2.
Select the number of tightenings to perform (5 by default, 50 as a maximum).
According to the test bench use, the tightening may be preceeded by a loosening.
3.
Click "Start calibration".
4.
Start performing the first loosening / tightening operation. The operation must be successful.
5.
At the end of each operation, enter the torque value on the measuring unit.
6.
When all operations are performed, a new calibration value is displayed.
Checking before putting back into service
Prior to putting the equipment back into service, check that its main settings have not been modified and that the
safety devices work properly.
Advanced tool maintenance with ACCESS KEY
Launch CVIMONITOR.
To activate the screens, you need to have an ACCESS KEY USB stick with the right profile (configured with the
Desoutter CVIKEY software).
If not, contact your CVIKEY manager for support.
Motor align
Click this icon.
Click
Motor align
.
It is mandatory to calibrate the tools after a motor align.