Operation
EN
14 / 24
06/2020
LED color
Description
Action to do
Yellow
Incomplete rundown
Tighten again.
Yellow and red (orange)
Reject report
Loosen and tighten again.
Red
Above max. limits
Remove and replace the fastener.
How to reverse the rotation
1
Run reverse button
Press this button.
Red and green LEDs are blinking alternatively.
Apply the tool to the fastener and press the trigger.
How to smooth the tool stop
The "Ergostop" function must be disabled for tightening tests or certification on tightening benches.
Ergostop allows a smoother tool stop to reduce the torque reaction on the operator.
When delivered, this function is disabled.
Go to the main screen.
Press this button during 2 seconds.
Go to
Ergostop
. Use the buttons to enable or disable the function, save and validate.
How to wake up EABA tools
The tool display switches off automatically after 2 minutes of inactivity.
Press the trigger.
The tool powers off after 30 minutes of inactivity.
Long press the reverse button.
Refer to "Power off" configurable on tool display or with CVI CONFIG.
Unplug and plug the battery pack.
Results monitoring
Connect the tool to a PC by using the eDOCK device.