EN
Operation
06/2020
11 / 24
Parameter
Description
Start torque
This is the torque value that must be reached to declare the
Pset as started. Below this value, neither result or report will
be generated.
Angle threshold
This is the torque threshold value used to start counting the
angle.
Rundown speed
Speed applied from the start to "Downshift torque".
Downshift torque
Torque value where the speed moves from "Rundown speed"
to "Downshift speed".
Final speed (or Downshift speed)
Speed applied from "Downshift torque" to the motor stop.
Max. time
30 sec by default. The tool stops when the time is reached.
Motor control
Starting at the "Start" signal, the tool runs with a programmed acceleration up to "Rundown speed".
The tool keeps running at "Rundown speed".
Once "Downshift torque" has been reached, the speed changes to "Downshift speed".
Item
Parameter
Description
1
Pset start torque
The
Pset start torque
is the torque
value that must be reached to declare the
Pset as started.
Below this value, neither result or report
will be generated.
2
Rundown speed
Speed applied from the start to "Down-
shift torque".
3
Downshift torque
Torque value where the speed moves
from "Rundown speed" to "Downshift
speed".
4
Downshift speed
Speed applied from "Downshift torque"
to the motor stop.
Operating Instructions
How to use the tool
How to select the Pset to run
Go to the main screen.
Select the Pset to run.
Press this button during 2 seconds.
Press this button to reach
Pset
.
Содержание 6151659610
Страница 23: ......