Rev 07/04/2015
26
Parameter Description
Factory Value
P42
low pressure input contact type
0 = NA (input active with contact closed)
1 = NC (input active with contact open)
0
P43
low pressure input alarm delay
0
P44
compressor thermal protection input contact type
0 = NA (input active with contact closed)
1 = NC (input active with contact open)
0
P45
compressor thermal protection input alarm delay
0
P46
UV light on duration (duration of cabinet sterilisation)
5
P47
needle probe heating end temperature (with reference to the
needle probe)
45
P48
maximum duration of needle probe heating
15
P49
the temperature, below which the door elements are switched
on (with reference to the cabinet probe)
5
P50
P49 differential
2
P51
condenser fan activity in the absence of the condenser probe
(P61 = 0)
0 = in parallel with compressor
1 = on
1
P52
the temperature below which the condenser fan is switched off
in the presence of the condenser probe (P61 = 1) and on
condition that the compressor is on (with reference to the
condenser probe); see also P54
20
P53
P52 differential
5
P54
condenser fan switch off delay on switching off the compressor
in the presence of the condenser probe (P61 = 1); see also
P52
30
P55
chill and freeze cycle completion buzzer duration
3
P56
maximum buzzer duration during an alarm state
15
P57
elapsed time between switching on the compressor and pump
down valve activation (pump down in power up); also elapsed
time between deactivation of the pump down valve and
switching off the compressor (pump down in power down)
10
P58
defrost parameter units of measurement
0 = P25 h, P24, P26, P28 and P35 min
1 = P25 min, P24, P26, P28 and P35 s
0
P59
reserved
0
P60
probe type
0 = NTC
1 = PTC
0
P61
condenser probe enabling
1 = YES
0
P62
the temperature above which the condenser temperature
alarm is activated (with reference to the condenser probe)
70
P63
P62 differential
10
Содержание GBC-15
Страница 1: ...Service Manual Blast Chiller...
Страница 2: ...Rev 07 04 2015 2...
Страница 3: ...Blast chiller Service Manual 3 Rev 07 04 2015...
Страница 32: ...Rev 07 04 2015 32...
Страница 38: ...Rev 07 04 2015 38 Insert the 4 digits password 2810 and hit OK to enter the menu Click on PARAMETERS...
Страница 40: ...Rev 07 04 2015 40...
Страница 46: ...Rev 07 04 2015 6 All relevant temperature values and input output status will show in this screen...
Страница 50: ...Rev 07 04 2015 10 20 10 0 10 20 30 40 kOhms C kOhmsVsTempChart NTC 10kOhms 25 C ZOOM...
Страница 57: ...Blast chiller Service Manual 17 Rev 07 04 2015 L1 L2...
Страница 91: ...Blast chiller Service Manual 51 Rev 07 04 2015 6 SCHEMATICS 6 1 SCHEME OF COMPONENTS...
Страница 97: ...Blast chiller Service Manual 57 Rev 07 04 2015...
Страница 100: ...Rev 07 04 2015 60...