INSTALLATION
Continued
3" Min.
(7.6 cm)
Side W
all
Of
Appliance
Incoming
1/2" Gas Line
Permitted by
Local Codes
Sediment Trap
(Not Supplied)
Figure 24 - Sediment Trap
Figure 22 - Manual Shutoff Valve
Installation
Typical Exterior Wall Gas
Shutoff Installation
Key
Extension
Shutoff
Valve
For propane/LP connection only, the installer
must supply an external regulator. The exter-
nal regulator will reduce incoming gas pres-
sure. You must reduce incoming gas pressure
to between 11" and 14" of w.c. pressure. If
you do not reduce incoming gas pressure,
¿UHSODFHUHJXODWRUGDPDJHFRXOGRFFXU,QVWDOO
external regulator with the vent pointing down
as shown in Figure 23. Pointing the vent down
protects it from freezing rain or sleet.
Figure 23 - External Regulator with Vent
Pointing Down (Propane/LP Only)
Propane/LP
Supply Tank
External Regulator
with Vent Pointing
Down
IMPORTANT:
Install main gas valve (equip-
ment shutoff valve) in an accessible location.
The main gas valve is for turning on or shutting
off the gas to the appliance.
&$87,21 8VH RQO\ QHZ
EODFN LURQ RU VWHHO SLSH ,QWHU
-
QDOO\WLQQHGFRSSHUWXELQJPD\
EHXVHGLQFHUWDLQDUHDV&KHFN
your local codes. Use pipe of
GLDPHWHURUJUHDWHUWRDOORZ
SURSHUJDVYROXPHWR¿UHSODFH
,ISLSHLVWRRVPDOOXQGXHORVV
RIYROXPHZLOORFFXU
We recommend that you install a sediment
trap/drip leg in supply line as shown in Figure
24. Locate sediment trap/drip leg where it
is within reach for cleaning. Install in piping
V\VWHP EHWZHHQ IXHO VXSSO\ DQG ¿UHSODFH
Locate sediment trap/drip leg where trapped
matter is not likely to freeze. A sediment trap
traps moisture and contaminants. This keeps
WKHPIURPJRLQJLQWR¿UHSODFHJDVFRQWUROV,I
sediment trap/drip leg is not installed or is in-
VWDOOHGZURQJ¿UHSODFHPD\QRWUXQSURSHUO\
Check your building codes for any special
requirements for locating equipment shutoff
YDOYHWR¿UHSODFH
Installation must include an equipment shutoff
valve, union and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up.
137WDSPXVWEHXSVWUHDPIURP¿UHSODFH
Natural
- From
Gas Meter (5.5"
W.C. to 10.5" W.C.
Pressure)
Propane/LP
From
External Regulator
(11" W.C. to 14"
W.C. Pressure)