VENTING INSTALLATION
Continued
Pitch
Slope
Opening
$0D[
Used Flashing
Model No.
Flat
0°
15"
V6F-8DM
0-6/12
26.6°
16
1
/
8
"
V6F-8DM
6/12- 12/12
45.0°
20
3
/
8
"
V12F-8DM
)/$6+,1*,167$//$7,219)'0
259)'0
'HWHUPLQHÀDVKLQJWREHXVHGZLWKURRIRSHQ
-
LQJFKDUW6OLGHÀDVKLQJRYHUSLSHXQWLOEDVHLV
ÀDWDJDLQVWURRI5HSODFHDVPDQ\VKLQJOHVDV
QHHGHGWRFRYHUH[SRVHGDUHDDQGÀDVKLQJ
base. Secure in position by nailing through
shingles (see Figure 17). DO NOT NAIL
THROUGH FLASHING CONE.
Figure 16 - Roof Opening Measurements
PENETRATING ROOF
To maintain a 1" clearance to pipe on a roof
with a pitch, a rectangular opening must
be cut.
1. Determine center point where pipe will
penetrate roof.
2. Determine center point of roof. Pitch is
the distance the roof drops over a given
span, usually 12". A 6/12 pitch means that
the roof drops 6" for each 12" measure
horizontally down from roof rafters.
3. Use roof opening chart (Figure 16) to
determine correct opening length and
ÀDVKLQJUHTXLUHG
4. Remove shingles around opening mea-
sured. Cut out this section.
14
3
/
8
"
(36.5 cm)
30"
(76.2 cm)
1"
(2.5
cm)
1"
(2.5
cm)
Minimum Measurements
1"
(2.5 cm)
Opening "A"
Nail Only
Outer
Perimeter
of Flashing
Storm Collar
Flashing
Cone
Underlap Shingles
at Bottom
Overlap
Shingles Top
and Sides Only
Figure 17 - Flashing Installation
Installing Flashing on a Metal Roof
:KHQ LQVWDOOLQJ ÀDVKLQJ RQ D PHWDO URRI LW
is required that putty tape be used between
ÀDVKLQJDQGURRI)ODVKLQJPXVWEHVHFXUHG
to roof using #8 x 3/4" screws and then sealed
with roof coating to prevent leakage through
screw holes. A roof coating must also be ap-
SOLHGDURXQGSHULPHWHURIÀDVKLQJWRSURYLGH
a proper seal.
6WRUP&ROODU,QVWDOODWLRQ6&
Place storm collar over pipe and slide down
XQWLO LW LV VQXJ DJDLQVW RSHQ HGJH RI ÀDVK
-
ing (see Figure 18). Apply waterproof caulk
around perimeter of collar to provide a proper
seal.
Figure 18 - Storm Collar
Chimney
Pipe
Waterproof
Caulk
Storm
Collar
Flashing