5-10 Miscellaneous System Setup
XL™ Series
Live Readings:
When the unit is turned off, pressing the side button will turn it on and
display the value of the first item defined in the log report. The value will
be updated automatically. Pressing the button causes the next item in the
log report to be displayed. If the current sensor takes a long time to update
such as an SDI12 sensor, then pressing the button may be ignored until the
value is updated.
Run Pgm BASIC1:
In this mode pressing the side button causes the unit to execute the
BASIC-1 program.
PC Interface View Built In Display Screen
U - User Mode: Normal
User Mode [Normal]
The user mode option has always been a part of the XL series data loggers but until recent
versions has resided in a hidden menu, only accessible by the manufacture or select customers
that need access to this option. The default setting for this option is ‘NORMAL’ which handles
95% or more of our users. There are a few applications that require special handling. There are
some customers that have bought several hundred units and require a simple user mode for there
organization. For these reasons the user mode option exists. Below is a quick description of the
different user modes.
Normal:
This is the most common used mode and used by over 95% of the users. The
manual is also based around this mode.
NOAA:
This mode is only used with the H-350XL. This mode is intended for NOAA
when they or one of there contractors is running a PORTS application. NOAA
uses a special measurement algorithm when measuring water levels. This
basically is a 3 minute averaging technic this returns an average, standard
deviation, and number of outliers. This also collects data at a 6 minute rate. In
this mode the GOES data is also formatted based on there requirements. The
GOES format uses binary data with ASCII tags to identify the data. This format
requires special decoding. For complete information on this mode request the
supplement “NOAA GOES Format”. Again, this is only valid on the H-350XL.
LCRA:
This mode only applies to the H-350XL. This stands for Lower Colorado River
Authority. In this mode whenever the H-350XL measures the stage, the resulting
value is placed in the SDI-12 buffer so if the H-350XL is used as a sensor
connected to an SDI-12 master, the master can collect the data at any time from
the last measurement simply by issuing the data retrieval command, aD0!.
NIWA:
NIWA is the leading provider of Atmospheric and aquatic data and services in
New Zealand. The main difference here is the factory defaults are different than
Содержание H-350XL
Страница 1: ...XL Series Models H 350XL H 500XL H 510XL H 522 H 522 Plus Owner s Manual ...
Страница 30: ...2 16 Hardware Options and Installation XL Series ...
Страница 42: ...3 12 Using The Built In Keypad Display XL Series ...
Страница 46: ...4 4 PC Menu Interface Operation XL Series ...
Страница 58: ...5 12 Miscellaneous System Setup XL Series ...
Страница 66: ...6 8 Serial Port Options XL Series ...
Страница 74: ...7 8 System Configuration Files XL Series ...
Страница 84: ...8 10 System Status Menus Options XL Series ...
Страница 88: ...9 4 Scanning Options XL Series ...
Страница 156: ...15 12 Logging Options XL Series ...
Страница 198: ...16 42 Operation with the GOES Radio XL Series ...
Страница 216: ...19 6 Alarm Call Out XL Series ...
Страница 234: ...21 8 Operation with the H 355 Smart Gas System XL Series ...
Страница 246: ...22 12 Functions XL Series ...
Страница 268: ...23 22 XL BASIC Programming Guide XL SERIES ...