Relay Terminal

The Full-Time Continuous Monitor features a relay 

terminal that can be integrated with electronic locks, 

lights, buzzers, etc. The relay will activate when a failure 

is reported by the Full-Time Continuous Monitor.

Contact Form

2 Form C

Maximum Switching Power 60 W, 125 VAC
Maximum Switching Voltage 220 VDC, 250 VAC
Maximum Switching Current 2 A
Maximum Carrying Current 2 A

NC

NO

C

Figure 12. Relay terminal contacts

10 mm Snap Adapters

The 19322 Full-Time Continuous Monitor includes an 

interchangeable 10 mm park snap and 10 mm banana 

jack adapter for operators who use wrist cords with 

10 mm terminations. Use the park snap's knurled rim 

to unscrew the 4 mm park snap from the monitor and 

install the 10 mm park snap to the monitor. Plug the 10 

mm operator jack adapter into the monitor's operator 

jack.

Figure 13. Installing the 10 mm snap adapters to the 

19322 Full-Time Continuous Monitor

Operation

1. Fit the wristband snugly onto the wrist.
2. Snap the wrist cord to the wristband.
3.

4.

Plug the wrist cord into the operator jack. The green

 

operator LED will illuminate. This indicates that the

 

operator is properly grounded.

If this does not happen, examine the wrist cord for

 

continuity or damage and the wristband to ensure

 

that it fits securely. If you have dry skin, apply an

 

approved dissipative hand lotion such as 

Menda

 

Reztore® ESD Hand Lotion.

5. When leaving the workstation, first touch the

monitor's park switch or park snap. The monitor's

audible alarm will disable for approximately 8

seconds. Use this time to disconnect the wrist cord

from the wristband and attach it to the park snap

without sounding a false alarm.

6. Upon returning to the workstation and disconnecting

the wrist cord from the park snap, the monitor will

provide approximately 8 seconds for the operator to

reconnect the wrist cord to a worn wristband before

sounding the monitor's alarm.

Figure 14. Using the Full-Time Continuous Monitor when 

mounted underneath a workbench tabletop

Test Equipment Depot - 800.517.8431 - 

5 Commonwealth Ave,

 Woburn,

MA 01801 

 - TestEquipmentDepot.com 

Содержание TB-3086

Страница 1: ...peak at 1 to 2 microamperes 0 000002 amperes to the wrist strap that is connected to the continuous or constant monitor The test voltage creates a square wave that the monitor circuit compares to established patterns By monitoring the distortions or shape of the square wave Wave Distortion Technology determines if the monitored circuit is complete the operator is in the circuit and the total equiv...

Страница 2: ...ountersunk Washer 1 Flat Head Screw 6 32 x 1 4 2 Pan Head Screws 6 x 3 8 1 Dual Lock Fastener Set 2 Length 1 10mm Interchangeable Park Snap 1 10mm Operator Jack Adapter 1 Power Cord with UK Plug 1 Certificate of Calibration 19323 Remote Alarm 1 Power Relay 1 Interface Cable 1 Power Cord with North American Plug Figure 3 Desco 19321 Full Time Continuous Monitor packaging contents Figure 4 Desco 193...

Страница 3: ...d park a wrist strap when leaving the workstation without creating a false alarm Touch the park snap or park switch and the monitor s audible alarm will disable for approximately 8 seconds Use this time to disconnect the wrist cord from the wristband and attach it to the park snap or remove the banana plug from the jack Upon returning to the workstation and disconnecting the wrist cord from the pa...

Страница 4: ... cord here Figure 8 Installing the Full Time Continuous Monitor Mat Monitor Cord Full Time Continuous Monitor Grounded Worksurface Mat Power Cord Countersunk Washer Flat Head Screw 1 Remove the Full Time Continuous Monitor from the carton and inspect for damage 2 Determine the mounting location of the Full Time Continuous Monitor Its LEDs should be visible to the operator Secure the Full Time Cont...

Страница 5: ...ous Monitor Connect the opposite end to the green connector on the side of the Power Relay 4 Connect the power cord from the Full Time Monitor to the Always ON receptacle on the Power Relay 5 Connect the power cord of the external electronic device to one of the Normally OFF receptacles on the Power Relay 6 Toggle the power switch to the RESET position Both the Full Time Continuous Monitor and the...

Страница 6: ... the wristband snugly onto the wrist 2 Snap the wrist cord to the wristband 3 4 Plug the wrist cord into the operator jack The green operator LED will illuminate This indicates that the operator is properly grounded If this does not happen examine the wrist cord for continuity or damage and the wristband to ensure that it fits securely If you have dry skin apply an approved dissipative hand lotion...

Страница 7: ...rials In general Desco recommends that calibration be performed annually Use the Desco 98221 Wave Distortion Monitor Verification Tester to perform periodic verification once every 6 12 months of the Full Time Continuous Monitor The verification tester can be used to check the test limits of the Full Time Continuous Monitor without removing it from the workstation See TB 3074 for more information ...

Страница 8: ...The worksurface mat must have a conductive layer such as Dual Layer Rubber or Dissipative 3 Layer Vinyl with conductive buried layers Desco workstation monitors are not recommended for use with homogeneous matting ANSI ESD S20 20 requires the use of a surface resistance meter for periodic verification of a worksurface s resistance to ground Rtg Constant monitors may not be used as a substitute for...

Отзывы: