background image

TB-6601

 Page 1 of 7

© 2019 DESCO INDUSTRIES INC

Employee Owned

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

Combo Tester X3+

Installation, Operation and Maintenance

Description

The Desco Combo Tester X3+ verifies the functionality 

of personnel grounding devices (wrist straps

1

, foot 

grounders, ESD shoes, smocks

2

). Three independent 

tests are performed simultaneously on the wrist strap 

and each foot. Test prompts and test results with 

resistance measurements are displayed on the 5 inch 

color touchscreen display. The administrator menu in 

the tester’s software may be accessed for test limit 

preferences. Access control to an ESD Protected Area 

can be further enforced by using the relay terminal on 

the Combo Tester X3+ and connecting it to an electronic 

door lock or turnstile to grant access only to those who 

have passed their personal grounding device tests. The 

Combo Tester X3+ is calibrated to NIST standards and 

includes a certificate.
Desco Combo Tester X3+ Technology

•  5 inch color touchscreen displays test prompts and 

test results with resistance measurements

•  The solid-state touch test switch maintains test 

accuracy and extends the lifetime of the tester

•  The 30 volt test signal increases test reliability

•  Pairs with the EMIT 

50755

 ESD Glove Test Fixture 

to test operators that wear ESD gloves or finger cots 

per Compliance Verification required by ESD TR53

September 2019

Figure 1. Desco ASK-37525 Combo Tester X3+

The factory test limits are set to:

Wrist Straps:  750 kilohms and 10 megohms

Footwear: 

750 kilohms and 35 megohms

(See page 5 for alternate test limit settings)
The Combo Tester X3+ and its accessories are 

available as the following item numbers:

Item

Description

ASK-37525

Combo Tester X3+

50416

Stand

50755

ESD Glove Test Fixture

50424

Limit Comparator

50785

Power Adapter, 100-240 VAC Input, 5 

VDC 3.0 A Output, All Plugs

50757

Replacement Dual Foot Plate

50787

Replacement Foot Plate Cord

Packaging

1  Combo Tester X3+

1  Mounting Bracket

1  Dual Independent Foot Plate

1  Power Adapter, 5VDC, with interchangeable plugs 

 (North America, UK/Asia, Europe)

1  Foot Plate Cable, 6.5 feet

1  Ground Cord

1  Thumb Screw

2  Mounting Anchors

2  Mounting Screws

2  Zip Ties

1  Plunger and Spring Assembly for 10mm Wrist Cord 

 Adapter

1  Certificate of Calibration

Made in the

United States of America

  TECHNICAL BULLETIN TB-6601

1.  The Combo Tester X3+ can verify single-wire and dual-wire wrist 

straps.

2.  The Combo Tester X3+ will also test a Groundable Static Control 

Garment System. The Groundable Static Control Garment System 

must have an RTG of < 3.5 x 10⁷ ohms to meet the required limit 

of ANSI/ESD S20.20 tested per ANSI/ESD STM2.1 and ESD 
TR53.

Содержание Combo Tester X3+

Страница 1: ...t test signal increases test reliability Pairs with the EMIT 50755 ESD Glove Test Fixture to test operators that wear ESD gloves or finger cots per Compliance Verification required by ESD TR53 September 2019 Figure 1 Desco ASK 37525 Combo Tester X3 The factory test limits are set to Wrist Straps 750 kilohms and 10 megohms Footwear 750 kilohms and 35 megohms See page 5 for alternate test limit sett...

Страница 2: ...mployee Owned DESCO WEST 3651 Walnut Avenue Chino CA 91710 909 627 8178 DESCO EAST One Colgate Way Canton MA 02021 1407 781 821 8370 Website Desco com Features and Components Figure 2 Combo Tester X3 features and components A B C D E F G H I J K L M ...

Страница 3: ...terminal termination of the cord to equipment ground This connection will remove any static charge from the user before the test NOTE Failure to correctly ground the Combo Tester X3 may result in damage not covered under warranty M ESD Glove Test Fixture Port Used for connecting the EMIT 50755 ESD Glove Test Fixture See TB 6586 for more information Installation Hardware Setup If the Combo Tester X...

Страница 4: ...bly into the single wire jack on the face of the Combo Tester X3 Be sure to clear the clip at the base of the plunger s shaft when inserting into the jack 6 Connect the Combo Tester X3 to the bracket Use the included thumbscrew to secure the tester as shown below Figure 4 Securing the Combo Tester X3 to the mounting bracket Figure 5 Use the EMIT 50416 Stand as a mounting alternative 2 The plunger ...

Страница 5: ...50 Kilohms 7 5 x 105 HIGH Limit Resistance HIGH Limit Resistance 10 Megohms 1 0 x 107 10 Megohms 1 0 x 107 35 Megohms 3 5 x 107 35 Megohms 3 5 x 107 100 Megohms 1 0 x 108 1 Gigohm 1 0 x 109 Default Settings A dirty foot plate could result in a false pass when the footwear limit is set to 1 Gigohm Be sure to keep the foot plate clean with 99 isopropyl alcohol when using this setting This setting is...

Страница 6: ...ill become solid to indicate that the test has been initiated Hold your finger down until the test results are displayed on the touchscreen If your finger is removed too early the tester s blue LEDs will blink three times to indicate that the test was not completed DO NOT touch any other metal while performing your test as this will affect your results 5 The relay terminal will activate if the def...

Страница 7: ...r Power Input 100 240VAC 50 60 Hz Power Output 5VDC 3 0A Cable Length 5 ft 1 5 m Operating Temperature 70 F to 85 F 21 C to 30 C for 1 gigohm test limit 41 F to 85 F 5 C to 30 C for all other test limits Environmental Requirements Indoor use only at altitudes less than 6500 ft 2 km Maximum relative humidity of 80 up to 85 F 30 C decreasing linearly to 50 85 F 30 C Maximum relative humidity of 50 a...