background image

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

TB-3019

 Page 4 of 5

© 2019 DESCO INDUSTRIES INC

Employee Owned

Operator Test Voltage
+5V

SW1 Position: RIGHT

SW2 Position: LEFT

+8V

SW1 Position: LEFT

SW2 Position: RIGHT

Operator High Test Limit
10 megohms

SW3 Position: RIGHT

35 megohms

SW3 Position: LEFT

Calibration

The Dual-Wire Dual Operator Monitor is calibrated to 

standards traceable to NIST. Frequency of recalibratrion 

should be based on the critical nature of those ESD 

sensitive items handled and the risk of failure for the 

ESD protective equipment and materials. In general, we 

recommend that calibration be performed annually.
Use the EMIT 

50524

 Limit Comparator for Dual-Wire 

Monitors to perform periodic testing (once every 6-12 

months) of the Dual-Wire Dual Operator Monitor. The 

Limit Comparator can be used on the shop floor within a 

few minutes virtually eliminating downtime, verifying that 

the monitor is operating within tolerances.
See 

TB-6542

 for more information.

Figure 5. EMIT 50524 Limit Comparator for Dual-Wire 

Monitors

Specifications

Input Voltage and 

Frequency

(External Adapter)

AC/DC Power Adapter
Power Input: 

100-240 VAC, 50/60 Hz
Power Output: 

12 VDC @ 0.50 A
Cable Length: 

5 ft. (1.5 m)

Operating Temperature 50 to 95 °F (10 to 35 °C)
Environmental 

Requirements

Indoor use only at altitudes 

less than 6500 ft. (2 km)
Maximum relative humidity 

of 80 % up to 85 °F (30 °C) 

decreasing linearly to 50 % 

@ 85 °F (30 °C)

Dimensions 

(Monitor)

4.4" x 4.7" x 2.1"

(112 mm x 119 mm x 53 mm)

Weight

(Monitor)

1.1 lbs. (0.5 kg)

Operator Test Range

1.91 megohms to 35 

megohms (default)

or

1.91 megohms to 10 

megohms (±10 %)

Worksurface Test 

Limit*

3.5 megohms (±10 %)

Operator Test Voltage 8 V (default) or 5 V
Worksurface Test 

Voltage

200 mV

Country of Origin

United States of America

*

The worksurface mat must have a conductive 

layer such as Dual Layer Rubber or Dissipative 

3-Layer Vinyl with conductive buried layers. Desco 

workstation monitors are not recommended for use with 

homogeneous matting.
ANSI/ESD S20.20 requires the use of a surface 

resistance meter for periodic verification of a 

worksurface’s resistance-to-ground (Rtg). Constant 

monitors may not be used as a substitute for this 

requirement.

Содержание 19665

Страница 1: ...ords shall be established and maintained to provide evidence of conformity to the technical requirements Per ANSI ESD S1 1 Annex A 3 Daily wrist strap system testing may be omitted if constant monitoring used Per ESD Handbook ESD TR 20 20 section 5 3 2 4 4 Typical Test programs recommend that wrist straps that are used daily should be tested daily However if the products that are being produced ar...

Страница 2: ...Monitors a worksurface mat for proper dissipative resistance and static charges Connect the black monitor cord here K Data Output For manufacturer use only L Alarm Audible Adjustment Turn the trimpot counter clockwise to increase the audible alarm volume and clockwise to decrease it Installation 1 Determine the mounting location of the Dual Wire Dual Operator Monitor The front panel should be visi...

Страница 3: ...eds to pierce and clinch bottom side of mat Snap needs to be at least 12 apart or 72 max OPERATOR 1 WORKSURFACE OPERATOR 2 WORKSURFACE 10mm PUSH CLINCH SNAP 10mm PUSH CLINCH SNAP BENCH GROUND MAT 1 WIRING WHITE CABLE MAT 2 WIRING BLACK CABLE WRIST STRAP MONITOR WRIST STRAP MONITOR ELECTRIC GROUND OPERATOR 2 REMOTE JACK BLACK CABLE OPERATOR 2 REMOTE JACK WHITE CABLE Screw allows ground cord to be b...

Страница 4: ...rances See TB 6542 for more information Figure 5 EMIT 50524 Limit Comparator for Dual Wire Monitors Specifications Input Voltage and Frequency External Adapter AC DC Power Adapter Power Input 100 240 VAC 50 60 Hz Power Output 12 VDC 0 50 A Cable Length 5 ft 1 5 m Operating Temperature 50 to 95 F 10 to 35 C Environmental Requirements Indoor use only at altitudes less than 6500 ft 2 km Maximum relat...

Страница 5: ... Website Desco com TB 3019 Page 5 of 5 2019 DESCO INDUSTRIES INC Employee Owned Figure 7 Operator Remote dimensions Replacement remotes are available as Desco items 50525 and 50526 Limited Warranty Warranty Exclusions Limit of Liability and RMA Request Instructions See the Desco Warranty Desco com Limited Warranty aspx ...

Отзывы: