background image

www.desatech.com

901273-01H

20

KEY 
NO.

PART NUMBER

DESCRIPTION

VSLR18

VSLR24

VDLCR18 VDLCR24

VDLCR30

QTY.

1

901565-02 901566-02 901567-02

Bottom Rear

1

2

901603-01 901604-01 901604-04

Bottom Front

1

3

901593-01 901594-01 901595-01

Bottom Front

1

4

901580-02

VR-11\VC Top Log

1

5

901588-01 901588-01 901588-01

VS-12 Top Log

1

6

901592-01 901592-01

VCR-12 Top Log

1

7

901591-02 901591-02 901591-02

VCR-11\VC Top Log

1

8

901551-03 901551-03 901551-03

CHR-13\VC Top Log

1

9

901587-01 901587-01 901587-01

VCR-9 Top Log

1

10

901625-03 901626-03

Bottom Rear

1

11

901583-01 901584-01

Bottom Front

1

12

901541-02 901541-02

 —

CPR-13\VR Top Log

1

13

901580-01 901580-01

VR-11\VR Top Log

1

14

901579-01 901579-01

VR-10Y Top Log

1

15

901578-01

VR-10 Top Log

1

ParTs

HANOVER ROUND OAK LOG MODELS VSLR18 AND VSLR24 

KINGSTON SPLIT OAK LOG MODELS VDLCR18, VDLCR24 AND VDLCR30

This  list  contains  replaceable  parts  used  in  your  log  set.  When  ordering  parts,  follow  the 
instructions listed under 

Replacement Parts

 on page 22 of this manual.

4

2

7

8

5

6

9

3

15

12

1

14

13

10

11

Kingston Split Oak Logs

Hanover Round Oak Logs

Содержание VVDA30R

Страница 1: ...not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this o...

Страница 2: ...shock and carbon monoxide poisoning DANGER Carbonmonoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or n...

Страница 3: ...Continued flamepatterns Ceilingfanscancreatedrafts that alter burner flame patterns Altered burner patterns can increase sooting 9 Do not use a blower insert heat exchang er insert or other accessory...

Страница 4: ...to convert to propane LP gas use WARNING The Massachu setts State Board requires all installations be performed by a Licensed Plumber or Gas Fit ter Massachusetts state code requires all vent dampers...

Страница 5: ...he flame and remove any obstruc tion until proper venting is achieved Burner Orifice LOG SIZE Natural Propane LP In Num CLR In Num CLR 18 SA DA 0 129 30 Green 0 073 49 Red 24 SA 0 141 28 Yellow 0 086...

Страница 6: ...er 5 W C to 10 5 W C Pressure CSA Design Certified Equipment Shutoff Valve With 1 8 NPT Tap Approved Flexible Gas Hose no longer than 36 if required by local codes Damper Damper Clamp Damper Manufactu...

Страница 7: ...ose equipment shutoff valve see Figure 5 2 Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter 3 Check all joints from gas meter to eq...

Страница 8: ...7 Removing Installing Thermocouple Pilot and Piezo Ignitor Cover Figure 8 Remove Burner Inlet Fitting Burner Inlet Fitting for Natural Gas Burner Pan 7 Using thread sealant resistant to the ac tion o...

Страница 9: ...e see Figure 12 with pro pane LP pilot orifice with red stripe 3 Replace and tighten pilot line to bracket 4 Reattach pilot and piezo ignitor assembly to valve cover with screws previouly removed see...

Страница 10: ...ons included with ac cessory Connect wires as shown in Figure 13 You will need to route wiring away from gas control and log set in a way which prevents direct radiant heat on wires No Optional Access...

Страница 11: ...r because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building...

Страница 12: ...er by the edge of the burner pan to look for flame If needed keep pressing ignitor button until pilot lights O F F P I L O T O N Figure 17 Control Knob and Ignitor Button Location Shown as Supplied No...

Страница 13: ...del HRC201 Hold the control button on the hand held remote until burner turns on Hold the control button again until burner turns off To Lock press both buttons on hand held remote control until light...

Страница 14: ...clean and clear of debris Occasionally you may use a soft bristle brush to clean logs Periodically inspect the air mixer and burner tube for foreign matter blocking the air inlet and flame holes Once...

Страница 15: ...ssage of air gas across irregular surfaces 2 Excessive gas pressure on natural gas units 1 Relieve any tight bends or kinks in gas supply line 2 Have inlet gas pressure checked by a qualified ser vice...

Страница 16: ...long enough 3 Equipment shutoff valve not fully open 4 Pilot flame not touching thermocouple which al lows thermocouple to cool causing pilot flame to go out This problem could be caused by one or bo...

Страница 17: ...king ticking noise just after burner is lit or shut off 1 Metal expanding while heating or contracting while cooling 1 This is normal with most log sets If noise is excessive contact qualified service...

Страница 18: ...desatech com 901273 01H 18 Parts Models VVSA18R VVSA24R VVDA18R VVDA24R and VVDA30R FVSA18R FVSA24R FVDA18R FVDA24R and FVDA30R I L 3 15 18 21 16 13 24 6 4 17 22 20 17 14 23 10 7 5 5 9 9 11 12 1 19 2...

Страница 19: ...0 01 Grate Steps 2 901431 01 Grate Steps 2 10 901243 01 Log Grate 1 901243 02 Log Grate 1 901246 01 Log Grate 1 901246 02 Log Grate 1 901246 03 Log Grate 1 11 901681 01 Burner STrap 1 12 901078 01 Nut...

Страница 20: ...R 13 VC Top Log 1 9 901587 01 901587 01 901587 01 VCR 9 Top Log 1 10 901625 03 901626 03 Bottom Rear 1 11 901583 01 901584 01 Bottom Front 1 12 901541 02 901541 02 CPR 13 VR Top Log 1 13 901580 01 901...

Страница 21: ...901614 01 901614 01 FS15 Top Log 1 9 901623 02 FR14 Top Log 1 10 901625 01 901626 01 Bottom Rear Log 1 11 901635 01 901636 01 Bottom Front Log 1 12 901620 01 901620 01 FR12L Top Log 1 13 901622 01 90...

Страница 22: ...of this product If they can t supply original replacement part s call DESA Heating LLC at 1 866 672 6040 for referral information A list of authorized dealers can be found by visiting www desatech co...

Страница 23: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 24: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: