www.desatech.com
119426-01A
9
MINIMUM FIREPLACE CLEARANCE TO
COMBUSTIBLE MATERIALS
Log Size
18", 24", 30"
Side Wall
16"
Ceiling
42"
Floor
5"
LOG SIZING REQUIREMENTS
Minimum Firebox Size
Log
Front
Rear*
Size Height Depth Width
Width
18"
17"
14"
20"
14"
24"
17"
14"
26"
18"
30"
17"
14"
32"
22"
*Measured at 14" depth
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
IMPORTANT:
Vent-free heaters add moisture to
the air. Although this is beneficial, installing heater
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See
Air
for Combustion and Ventilation
, page 6.
CHECK GAS TYPE
Use the correct type of gas (natural or propane/LP).
If your gas supply is not the correct gas type, do
not install heater. Call dealer where you bought
heater for proper type heater.
WARNING: This appliance
is equipped for natural or pro-
pane/LP gas. Field conversion
is not permitted.
INSTALLATION AND CLEARANCES
FOR VENT-FREE OPERATION
WARNING: Maintain the
minimum clearances. If you
can, provide greater clearances
from floor, ceiling and adjoining
wall.
INSTALLATION
Continued
Carefully follow the instructions below. This will
ensure safe installation into a masonry, UL127-
listed manufactured fireplace or listed vent-free
firebox.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 4.
Example:
The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/
2
" from the wall. This combus
-
tible material must be 4" from the side of the
fireplace cabinet (see Figure 4).
Note:
When installing your gas logs into
a manufactured firebox, follow firebox
manufacturer’s instructions for minimum
clearances to combustible materials.
B. Clearances from the top of the fireplace
opening to the ceiling should not be less than
42".
Figure 4 - Minimum Clearance for
Combustible to Wall
*Minimum 16" from Side Wall
*
Example