LOCAL CODES

Install and use fireplace with care. Follow all local 

codes. In the absence of local codes, use the lat-

est edition of 

The National Fuel Gas Code, ANSI 

Z223.1/NFPA 54

*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY  10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA  02269

UNPACKING

 CAUTION: Do not remove the 

data plates attached to the heater 

base assembly. The data plates 

contain important warranty and 

safety information.

1.  With utility knife, cut the carton all the way 

around above the staples on the bottom tray. 

Lift the carton off the heater. Remove packing. 

Note: 

The hood is located in the packing on 

the right hand side of the heater front. Lift the 

heater off the bottom tray. 

2.  Locate two screws above top corners of the 

fireplace screen. Remove and discard these 

screws. Lift fireplace screen up and pull out 

to remove. 

3.  Remove protective packaging applied to logs, 

log base assembly, and fireplace. 

4.  Remove fireplace hood from carton insert. 
5.  Check all items for any shipping damage. If 

damaged, promptly inform dealer where you 

bought fireplace.

PRODUCT FEATURES

OPERATION

This vent-free fireplace is clean burning. It requires 

no outside venting. There is no heat loss out a vent 

or up a chimney. Heat is generated by both realistic 

flames and glowing embers. When used without the 

optional blower, the fireplace requires no electricity 

making it ideal for emergency backup heat. 

SAFETY DEVICE

This fireplace has a pilot with an Oxygen Depletion 

Sensing (ODS) safety shutoff system. The ODS/

pilot is a required feature for vent-free room heat-

ers. The ODS/pilot system shuts off the fireplace 

if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This system 

requires no matches, batteries, or other sources 

to light fireplace.

WIRELESS REMOTE CONTROL

This fireplace features an infrared wireless remote 

control. This control system can be used to auto-

matically light the pilot and adjust the burner flame 

height at the push of a button.

WIRED WALL-MOUNTED REMOTE 
CONTROL

This fireplace features a two-button wall switch 

assembly with glowing LEDʼs. The wall switch 

performs the same functions as the wireless hand-

held remote control with the added feature of LEDʼs 

for visual feedback of operation and status.

BLOWER ASSEMBLY

This fireplace includes a blower assembly. The 

blower operates thermostatically. The blower circu-

lates heated air from the fireplace into the room.

AIR FOR COMBUSTION 

AND VENTILATION

 WARNING: This heater shall 

not  be  installed  in  a  confined 

space or unusually tight construc-

tion unless provisions are provid-

ed for adequate combustion and 

ventilation air. Read the following 

instructions to insure proper fresh 

air for this and other fuel-burning 

appliances in your home. 

Todayʼs homes are built more energy efficient 

than ever. New materials, increased insulation, and 

new construction methods help reduce heat loss 

in homes. Home owners weather strip and caulk 

around windows and doors to keep the cold air out 

and the warm air in. During heating months, home 

owners want their homes as airtight as possible.
While it is good to make your home energy effi-

cient, your home needs to breathe. Fresh air must 

enter your home. All fuel-burning appliances need 

fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel 

burning appliances draw air from the house to 

operate. You must provide adequate fresh air for 

these appliances. This will insure proper venting 

of vented fuel-burning appliances.

Содержание VTGF33NRB

Страница 1: ...t try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier UNVENTED VENT FREE GAS FIREPLACE OWNER S O...

Страница 2: ...ng plate This appliance is not convert ible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer TABLE OF CONTENTS Safety Information 3 Product Identification 4 Local Codes 5 Unpacking 5 Product Features 5 Air for Combustion and Ventilation 5 Installation 8 Operating Fireplace 21 Inspecting Burners 24 Cleaning and Maintenance 25 Specifications 26 Tr...

Страница 3: ...ngs Keep this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this heater or its controls can be dangerous WARNING Donotuseablow er insert heat exchanger insert orotheraccessorynotapproved for use with this heater WARNING Donotallowfans toblowdirectlyintothefireplace Avoidanydraftsthatalterburner flame patterns Ceiling fans can create drafts th...

Страница 4: ...or on adjacent walls or furniture 9 This fireplace needs fresh air ventilation to run properly This fireplace has an Oxygen Deple tion Sensing ODS safety shutoff system The ODS shuts down the fireplace if not enough fresh air is available See Air for Combustion and Ventilation page 5 If fireplace keeps shutting off see Troubleshooting pags 27 10 Do not run fireplace where flammable liquids or vapors are...

Страница 5: ...place if there is not enough fresh air PIEZO IGNITION SYSTEM This fireplace has a piezo ignitor This system requires no matches batteries or other sources to light fireplace WIRELESS REMOTE CONTROL This fireplace features an infrared wireless remote control This control system can be used to auto matically light the pilot and adjust the burner flame height at the push of a button WIRED WALL MOUNTED RE...

Страница 6: ...er hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms com municating directly with the space in which the appliances are installed through openings not furnished with ...

Страница 7: ... ANSIZ223 1 NFPA54Section5 3 or applicable local codes AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining un confined space When ventilating to an adjoining unconfined space you must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces...

Страница 8: ... against any exterior surface on the rear sides or top of your fireplace except where standoff spacers are integrally attached If standoff spacers are attached to your fireplace these spacers can be placed directly against wall or framing materials Use the dimensions shown for rough openings to create the easiest installation see Built In Fire place Installation page 17 IMPORTANT Vent free heaters a...

Страница 9: ... gas connections required 7 Firebox installation conventional or built in required 8 Installing perimeter trim optional 9 Installing fireplace hood required 10 Installing logs required 11 Installing fireplace screen required Use the following instructions to complete each step Figure 6 Removing Fireplace Floor Assembly Screw Fireplace Floor Assembly REMOVING FIREPLACE SCREEN AND FLOOR ASSEMBLY NOTIC...

Страница 10: ...Note A qualified installer must make all electrical connections RELOCATING WALL SWITCH ASSEMBLY Note The decorative wall switch plate supplied is white The wall switch plate may be painted to match your decor The push button switch and decorative wall plate assembly supplied with your fireplace is pre mounted at the factory in the lower cavity of the fireplace You may relocate this wall switch assemb...

Страница 11: ...on without straining cord assembly If you are mounting wall switch assembly to a wall continue reading If you are mounting your wall switch assembly to the side of the mantel see page 12 CAUTION Do not apply ex cessive pull on cord Mounting Wall Switch Assembly to Wall for Recessed Fireplace 7 Create three openings on wall according to Template 1 page 39 This is best done by making a pattern to wo...

Страница 12: ...e mantel wall ac cording to Template 2 page 39 This is best done by making a pattern to work with on the mantel Carefully cut page 39 from manual and tape paper template vertically onto mantel wall at preferred location Pierce the paper at the centers of the 2 holes with a nail or sharp pencil leaving a mark on the wall Do the same at centers of the four circles near the corners of the rectangle 8...

Страница 13: ... See Accessories page 36 INSTALLATION Continued For propane LP units the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 inches of water If you do not reduce incoming gas pres sure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figu...

Страница 14: ...ed 5 16 hex socket wrench or nut driver Phillips screwdriver sealant resistant to propane LP gas not provided 1 If fireplace screen and floor are still installed see Removing Fireplace Screen and Floor Assembly page 9 2 Route gas line provided by installer from equipment shutoff valve to fireplace Route flexible gas supply line through one of the access holes NOTICE Most building codes do not permit c...

Страница 15: ...ropane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect fireplace and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than...

Страница 16: ...rectly on the floor 1 Assemble cabinet mantel hearth base and trim accessories Assembly instructions are included with each accessory 2 When installing blower install a properly grounded 120 volt three prong electrical out let at fireplace location if an outlet is not there If possible locate outlet so cabinet mantel will cover it when installed see Figure 20 3 If not already completed install gas p...

Страница 17: ...l the fireplace in this manner Actual Framing Height 32 3 8 33 Front Width 34 5 16 35 1 2 Depth 16 11 16 17 3 4 1 Frameinroughopening Usedimensionsshown in Figure 24 for the rough opening If installing in a corner use dimensions shown in Figure 25 for the rough opening The height is 33 which is the same as the wall opening above 2 Install and properly ground GA3555 three prong 120 volt electrical o...

Страница 18: ...Framing Material Figure 26 Attaching Fireplace to Wall Studs Nailing Flanges Nails or Wood Screws INSTALLATION Continued Mantel Clearances for Built In Installation If placing mantel above built in fireplace you must meet minimum clearance between mantel shelf and top of fireplace opening NOTICE Surface temperatures ofadjacentwallsandmantelsbe comehotduringoperation Walls and mantels above the firebo...

Страница 19: ...g edges of trim together tighten both set screws on the adjusting plate with slotted screwdriver 7 Repeat steps 1 through 6 for other side 8 Tighten trim hanging screws 10 x 6 25 shoulder into holes in cabinets Place the assembled trim onto fireplace cabinet Align hanging notches on trim with hanging screws on side of fireplace see Figure 29 Push trim firmly into place sliding hanging notches over ha...

Страница 20: ...ase over log alignment screws to the left of front burner and behind middle burner Log 1 will sit on top of front and middle burners see Figure 31 2 Place log 2 to right of log 1 and onto log alignment screw as shown in Figure 32 Log 2 will wrap around right end of rear burner 3 Place log 3 on left side of base and onto alignment screw to right of rear burner see Figure 32 Log 3 will wrap around l...

Страница 21: ...sonal injury or loss of life A This appliance has a pilot which lights automatically when using the supplied wall switch or remote control If you have a power outage the pilot may be lighted by hand with push button piezo ignitor When lighting the pilot the following warnings must be followed B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because so...

Страница 22: ...erson or gas supplier for repairs Until repairs are made light and operate manually see Manual Lighting Instructions for Electric Power Outage page 19 3 When pilot flame is lit the thermocouple is heated by the flame When thermocouple becomes hot 5 to 15 seconds main burner will automatically light on high flame 4 To lower flame push HI LO button on wall switch once Note This fireplace does not have a ...

Страница 23: ...LO Button Piezo Ignitor Wall Switch LED Figure 39 Control Locations Manual Ignition Bypass Switch Down is ON ON OFF Button Magnetic Manual Override Handle Gas Valve Because this fireplace has an electronic ignition system in the event there is a loss of power it will be necessary to manually light the pilot with the piezo ignitor After the pilot is lit the main burner will light automatically 1 Fol...

Страница 24: ...eater modulates to the pilot position the blower will continue to run The blower will shut off after the firebox temperature decreases Note It is safe to operate fireplace with blower turned off However the blowerhelps distribute heated air from the fireplace Figure 40 AUTO OFF ON Switch AUTO OFF ON Switch Piezo Ignitor Fan Switch INSPECTING BURNERS Check pilot flame pattern and burner flame pat terns ...

Страница 25: ...ualified service person Heater may need more frequent cleaning due to excessive lint fromcarpeting pethair bedding material etc WARNING Failure to keep the primary air opening s of theburner s cleanmayresultin sooting and property damage BURNER INJECTOR HOLDERS AND PILOT AIR INLET HOLES The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame...

Страница 26: ... cess hole for natural pilot is behind the pilot bracket on the top of burner carriage see Figure 47 You may blow through a drinking straw if compressed air is not available Figure 47 Cleaning Pilot Air Inlet Hole Pilot Air Inlet Hole Pilot Assembly Pilot Bracket CLEANING AND MAINTENANCE Continued Figure 45 Injector Holder On Outlet Burner Tube Rear Burner Figure 46 Injector Holder On Outlet Burne...

Страница 27: ...ged OBSERVED PROBLEM When buttons on remote control are pressed there is no response from fireplace When wall switch button is pressed there is no response from fireplace Burner does not light after ODS pilot is lit Delayed ignition burner REMEDY 1 Replace battery in remote control 2 Point remote control toward lower front panel of fireplace when operating 3 Place manual ignition bypass switch in OFF...

Страница 28: ...minimum installation clearances see page 8 4 Clean burner see Cleaning and Maintenance page 25 or replace burner orifice 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replace pilot assembly 7 Replace...

Страница 29: ... A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 25 or replace ODS pilot assembly 5 Hand tighten until snug then tighten 1 4 turn more 6 Replace pilot assembly 7 Replace control valve TROUBLESHOOTING Continued POSSIBLE CAUSE 1 Gas supply turned off or equipment shutoff valve closed 2 Control knob not in PILOT position 3 Air in gas lines when in...

Страница 30: ...d service person 1 Open window and ventilate room Stop using odor caus ing products while fireplace is running 2 Locate and correct all leaks see Checking Gas Connec tions page 15 1 Open window and or door for ventilation 2 Contact local gas company 3 CleanODS pilot seeCleaning and Maintenance page 25 1 Locate and correct all leaks see Checking Gas Connec tions page 15 2 Replace control valve 1 Tak...

Страница 31: ...ginal replacement part s call DESA Heating Productsʼ Technical Service Department at 1 866 672 6040 When calling DESA Heating Products have ready your name your address model and serial numbers of your fireplace how fireplace was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorize...

Страница 32: ...www desatech com 113134 01B 32 ILLUSTRATED PARTS BREAKDOWN REMOTE CONTROL LOG BASE ASSEMBLY MODELS VTGF33PRB AND VTGF33NRB SHOWN 60 59 ...

Страница 33: ...ndle 1 39 110108 01 Burner Shield 1 40 098544 01 Wire Support Clip 1 41 101629 01 1 5 Bushing 2 PARTS LIST REMOTE CONTROL LOG BASE ASSEMBLY MODELS VTGF33PRB AND VTGF33NRB This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Replacement Parts on page 31 of this manual KEY PART NO NUMBER DESCRIPTION QTY Not a field replacement part 42 104...

Страница 34: ...www desatech com 113134 01B 34 ILLUSTRATED PARTS BREAKDOWN FIREPLACE MODELS VTGF33NRB AND VTGF33PRB 23 24 5 4 11 19 12 9 14 9 21 9 9 20 10 2 3 1 13 22 8 7 10 15 15 16 17 18 18 6 ...

Страница 35: ... Firebox Hood 1 7 102759 02CK Left Front Side 1 8 102758 02CK Right Front Side 1 9 M11084 26 Hex Screw 10 60 10 099230 01 Shoulder Screw 4 11 Firebox Wrapper 1 12 101514 01 Cover 1 13 098304 01 Phillips Pan Head Screw 10 22 14 101348 01 Firebox Support 2 15 102455 18 Louver 2 16 104313 01 Hinge Pin 1 17 104313 02 Hinge Pin 1 18 M10908 2 Screw Slotted Hex Head Tapping 4 19 098304 02 Phillips Pan He...

Страница 36: ... fluting and medallion Three sided perimeter trim kit included Dimensions H xW xD 48 3 4 x 60 7 8 x 34 3 4 CORNER HEARTH BASE G3008F Series Walnut Finished G3009U Series Unfinished G3010F Series Oak Finished For all models The corner hearth base is designed for use with the corner mantels to create a hand some riser for the fireplace Dimensions WxHxD 6 x 52 1 2 x 23 3 4 CABINET MANTEL GMC11F Series W...

Страница 37: ...may also email your request to productsupport desaint com FIRE CRACKLE CF6 A Not Shown Creates the sound of a real burning fire LAMINATE TRIM FOR HEARTH OR MANTEL G3002J Series Jade Marble Laminate Mantel Trim G3003J Series Jade Marble Laminate Hearth Base Trim G3002S Series Sandstone Marble Laminate Mantel Trim G3003S Series Sandstone Marble Laminate Hearth Base Trim G3002B Series Black Onyx Marbl...

Страница 38: ...L MOUNT THERMOSTAT SWITCH GWMT1 Not Shown For all models The desired comfort setting can be selected on the wall thermostat and the fireplace will automatically cycle from pilot to the heat setting selected WALL MOUNT ON OFF SWITCH GWMS2 Not Shown For all models Allows the gas fireplace to be turned on and off with a wall switch CLEANING KIT GCK Not Shown For all models Your vent free gas appliance ...

Страница 39: ... 01B 39 Template 1 Relocating Wall Switch to Hollow Room Wall Template 2 Relocating Wall Switch to Side Wall of Mantel CUT HERE TEMPLATES 4 3 4 4 3 4 3 3 4 3 8 3 3 4 3 8 3 16 3 4 3 4 3 8 Diameter 2 Holes 1 8 Diameter 2 Holes ...

Страница 40: ...www desatech com 113134 01B 40 THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 41: ...ion the wires must be connected exactly as shown in wiring diagram MODULE SENSOR RECEIVER INDICATION BOARD PIEZO MANUAL OVERRIDE SWITCH VALVE PILOT IGNITOR ELECTRODE IGNITOR POWER CORD FAN SWITCH 3 2 1 BLOWER BLUE RED WHITE BROWN GREEN YELLOW BLUE BLACK WHITE GREEN C D ...

Страница 42: ...__________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________________...

Страница 43: ..._______ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _______...

Страница 44: ...stalled by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and ...