www.desatech.com
116192-01G
4
2. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use
any phone in your building
• immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier's
instructions
• if you cannot reach you gas supplier, call the
fire department.
3. Never install the fireplace
• in a recreational vehicle
• in windy or drafty areas where curtains or
other combustible (flammable) objects can
make contact with the fireplace front
• in high traffic areas
4. Turn fireplace off and let cool before servicing,
installing or repairing. Only a qualified service
person should install, service or repair this
fireplace. Have fireplace inspected annually
by a qualified service person.
5. You must keep control compartments, burn-
ers and circulating air passages clean. More
frequent cleaning may be needed due to ex-
cessive lint and dust from carpeting, bedding
material, etc. Turn off the gas valve and pilot
light before cleaning fireplace.
6. Have venting system inspected annually by a
qualified service person. If needed, have vent-
ing system cleaned or repaired. See
Cleaning
and Maintenance
, page 31.
7. Do not use any solid fuels (wood, coal, paper,
cardboard, etc.) in this fireplace. Use only the
gas type indicated on fireplace nameplate.
8. This appliance, when installed, must be electri-
cally grounded in accordance with local codes
or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70
or
the
Canadian Electrical Code, CSA C22.1.
9. Do not use fireplace if any part has been ex-
posed to or under water. Immediately call a
qualified service person to arrange for replace-
ment of the unit.
10. Do not operate fireplace if any log is broken.
11. Do not operate fireplace with glass door
removed, cracked or broken.
12. Provide adequate clearances around air
openings.
SAFETy INFORMATION
Continued
PRODUCT
IDENTIFICATION
Figure 1 - Direct-Vent Fireplace with
Millivolt Ignition
Glass
Door
Assembly
Switch Bracket for Optional
Remote and Blower
Control Valve
with Piezo
Ignitor
Log
Set
Lava
Rock
Glowing
Embers
Upper Louver
Panel
Lower
Louver
Panel
Flue Collar
Nailing
Flange
Burner
Assembly
LOCAL CODES
Install and use fireplace with care. Follow all local
codes. In the absence to local codes, use the cur-
rent
National Fuel Gas Code ANSI Z223.1/NFPA
54*
(USA) or the current
CSA-B149.1 Installation
Code
(Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269