VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE

VMH10TPA

®

4.

Carefully disconnect green and white
wires at their insulated connectors.

5.

In top of the heater cabinet, locate the
four mounting holes on the outer cas-
ing. Align these four holes with those
on the blower bracket assembly. Attach
blower bracket assembly to the outer
casing with 4 #10 screws provided (see
Figure 17).

Figure 17 - Installing Blower Bracket Assembly

3
2
1

Wire
Harness

Blower Bracket
Assembly

Screw

Power
Cord

Valve Cover
Shield

Box Cover

Wire
Harness

Switch
Plate

Switch

Baffle

Wiring Routing
Hole in Baffle

Blue

Red

6.

Route the wire harness through the
hole in left side of baffle. Pull wire
harness through lower opening above
where the valve shield was removed.
(see Figure 17).

7.

Insert the 4 wire harness into one of the
round holes in the rear of the valve cover
shield and through the rectangular hole
in the front of shield (see Figure 17).

8.

Reconnect red wire to switch position
3. Reconnect blue wire to switch posi-
tion 1. Reconnect green and white wires.

Figure 18 - Installing Switch Plate to Valve
Cover Shield

Switch
Plate

Screw

Valve Cover
Shield

INSTALLATION

Continued

9.

Install the switch plate on the valve
cover shield with 2 #10 screws provided
(see Figure 18). Reinstall the valve
cover shield. Route power cord out of
the cabinet by inserting it through the
bushing on the outer casing (see Fig-
ure 17). Plug fan kit into 120-Volt
grounded power supply and test opera-
tion. 

Note:

 When switch is in the

AUTO position, the fan will start after
the heater has run for a few moments.
The fan will continue to run for several
moments after the heater has been
turned off. When switch is in the ON
position, the fan will run until turned
to OFF. Reinstall upper louver assem-
bly and hood if previously removed,
(see Figure 15, page 11). Close lower
louver door.

Содержание Vanguard VMH10TPA

Страница 1: ...nt Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury...

Страница 2: ...bris could fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 9 This fireplac...

Страница 3: ...are packet 4 Checkfireplaceforanyshippingdamage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FEATURES SAFETY PILOT This fireplace has a pilot with an Oxygen Deplet...

Страница 4: ...con tact flame If flame contacts branch soot will be created 7 Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down Figure 2 Assembling Fireplace WARNI...

Страница 5: ...in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the outside atmosphere...

Страница 6: ...an support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free fireplace ______________________ Btu Hr Gas water heater ______________________ Btu Hr Gas furnace ___________________...

Страница 7: ...n Grills into Adjoining Room Option 1 WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both space...

Страница 8: ...the items listed below external regulator supplied by installer piping check local codes sealant resistant to propane LP gas manual shutoff valve test gauge connection ground joint union sediment trap...

Страница 9: ...r instruc tions for power cord length Option two Have a licensed electri cian install a properly grounded three prong 120 volt electrical outlet at fire place location Locate outlet inside the framed...

Страница 10: ...el above built in fireplace youmustmeetminimumclearancebetween mantel shelf and top of fireplace opening If your installation does not meet the below minimum clearances you must raise the mantel to an...

Страница 11: ...er Louver As sembly Upper Louver Assembly Brass Screws Blower Bracket Mounting Holes 1 2 Remove Screw Valve Cover Shield Shoulder Screw Removing Valve Cover Shield 1 Open bottom louver assembly by swi...

Страница 12: ...n the rear of the valve cover shield and through the rectangular hole in the front of shield see Figure 17 8 Reconnect red wire to switch position 3 Reconnect blue wire to switch posi tion 1 Reconnect...

Страница 13: ...rd ware kit into one of the holes found on rear of valve cover shield The other hole is for a strain relief clamp not supplied to secure incoming electrical supply 2 Follow steps 2 through 6 in Instal...

Страница 14: ...m going into fireplace controls If sediment trap is not installed or is installed wrong fireplace may not run properly Attaching Wood Base to Solid Floor For attaching base to solid floors concrete or...

Страница 15: ...gas con nections A flexible gas line is provided to allow accessibility fromthefireplace seeFigure24 The flexible gas supply line con nection to the manual shutoff valve should be accessible INSTALLAT...

Страница 16: ...Open Manual Shutoff Valve Figure 27 Checking Gas Joints Shown with Optional Mantel Figure 26 Manual Shutoff Valve Manual Shutoff Valve Propane LP Supply Tank Closed TestPressuresEqualToorLessThan 1 2...

Страница 17: ...a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified ser...

Страница 18: ...it Turn control knob clockwise to the PILOT position THERMOSTAT CONTROL OPERATION 1 Follow steps 1 through 5 under Light ing Instructions page 17 2 With control knob pressed in strike match Hold match...

Страница 19: ...ireplace off see To Turn Off Gas to Appliance page 18 see Troubleshooting pages 20 through 22 Thermocouple Pilot Burner Figure 32 Incorrect Pilot Flame Pattern Actual Pilot May Vary From Illustration...

Страница 20: ...Control valve damaged REMEDY 1 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace ignitor 6...

Страница 21: ...Dirty or partially clogged burner orifice 1 When heated vapors from furniture pol ish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner see Cleaning and Mainte nance page 23...

Страница 22: ...statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED PR...

Страница 23: ...st thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector holder for dust and dirt see Figure 35 3 Blow air through the ports slots and holes in the burner Figure 35 Injector Ho...

Страница 24: ...GAS COMPACT FIREPLACE VMH10TPA 44 23 28 31 43 35 37 13 14 3 43 32 11 10 4 7 29 1 3 2 3 42 9 17 19 6 22 30 21 40 27 38 38 16 15 18 24 5 33 26 25 20 4 8 4 34 36 12 24 12 1 25 14 43 39 41 ILLUSTRATED PAR...

Страница 25: ...87 01 Brass Screw 6 x 3 8 4 18 098303 02 Regulator Screw 2 19 104335 01CK Outer Shell Base 1 20 102649 02CJ Branch Support 1 21 099415 04 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23 101381 01...

Страница 26: ...pane LPornaturalgas purchase date Usually we will ask you to return the defec tive part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original...

Страница 27: ...or paint Complete assembly instructions in cluded Three sided brass trim kit included MANUAL SHUTOFF VALVE GA5010 Manual shutoff valve with 1 8 NPT tap THERMOSTATICALLY CONTROLLED BLOWER KIT GA3400T P...

Страница 28: ...efects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner T...

Отзывы: