background image

111253-01D

For more information, visit www.desatech.com

For more information, visit www.desatech.com

31

31

PARTS LIST

Models V36EN-A, V36EP-A, VV36ENSB(1), VV36ENHB(1), VV36EPSB(1), VV36EPHB(1)

PARTS LIST

This list contains replaceable parts used in your fireplace. When
ordering parts, follow the instructions listed under 

Replacement

Parts 

on page 34 of this manual.

V36ENS-A

VV36ENSB(1) V36ENHB(1) VV36ENHB(1)

V36EPS-A

VV36EPSB(1) V36EPHB(1) VV36EPHB(1)

DESCRIPTION

QTY

110989-02

110989-01

111215-02

111215-01

Left Refractory Brick Panel

1

110991-02

110991-01

111217-02

111217-01

Rear Refractory Brick Panel

1

110990-02

110990-01

111216-02

111216-01

Right Refractory Brick Panel

1

REFRACTORY BRICK PANELS

** Part not available for field replacement.

KEY

V36EN-A

VV36ENSB(1)

VV36ENHB(1)

NO.

V36EP-A

VV36EPSB(1)

VV36EPHB(1)

DESCRIPTION

QTY.

1

      **

      **

      **

Firebox Assembly

1

2

      **

      **

      **

Face Weldment

1

3

108010-01

108010-01

108010-01

Door Assembly (V Models Only)

1

108010-02

108010-02

108010-02

Door Assembly (VV Models Only)

4

108011-01

108011-01

108011-01

Top Panel Louver Assy

1

5

108011-02

108011-02

108011-02

Bottom Panel Louver Assy

1

6

      **

      **

      **

Fireplace Top

1

7

      **

      **

      **

Fireplace Top Insulation

1

8

      **

      **

      **

Fireplace Surround

1

9

109082-01

109082-01

109082-01

Heat Shield

1

10

108032-01

108032-01

108032-01

Log Set

1

  10-1

109128-01

109128-01

109128-01

Front Log (Log 1)

1

  10-2

109129-01

109129-01

109129-01

Rear Log (Log 2)

1

  10-3

109130-01

109130-01

109130-01

Crossover Log (Log 3)

1

  10-4

109131-01

109131-01

109131-01

Top Log (Log 4)

1

  10-5

109132-01

109132-01

109132-01

Left Log (Log 5)

1

  10-6

109133-01

109133-01

109133-01

Base Log (Log 6)

1

11

      ___

See Below

See Below

Left Refractory Brick Panel

1

12

      ___

See Below

See Below

Rear Refractory Brick Panel

1

13

      ___

See Below

See Below

Right Refractory Brick Panel

1

14

108076-01

108076-01

108076-01

Burner Base Gasket

1

15

108719-01

108719-01

108719-01

Screen Rod

1

16

12105

12105

12105

Screen

2

17

11418

11418

11418

Push-On Nut

2

18

14123

14123

14123

Strain Relief

1

19

21171

21171

21171

Gas Knock-Out Cover

2

20

24353

24353

24353

Handy Box Assembly

1

21

24460

24460

24460

Gas Conduit Assembly

1

22

108760-03

108760-03

108760-03

Burner Assembly (Natural Gas)

1

108760-04

108760-04

108760-04

Burner Assembly (Propane/LP Gas)

1

PARTS AVAILABLE - NOT SHOWN

25487

25487

25487

Lava Rock/Bag Assy

1

27253

27253

27253

Notice Label

1

55240

55240

55240

Vent Label

1

Содержание V36EP-A Series, VV36EPB(1) Series

Страница 1: ...ion adjustment alteration service or maintenance can cause injury orpropertydamage Refertothis manual for correct installation and operational procedures For assistance or additional infor mation cons...

Страница 2: ...em Itbringsinfreshairforcombustionthroughtheouterpipeand combustion gases are exhausted through the inner pipe If the glass door assembly and venting pipe are not properly seated connected and sealed...

Страница 3: ...se this fireplace to cook food or burn paper or other objects 13 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fireplace nameplate 14 Th...

Страница 4: ...the location of your fireplace follow these rules Do not connect this fireplace venting to a chimney flue serving a separate solid fuel burning fireplace or appliance Due to high temperatures do not...

Страница 5: ...combus tible mantels may discolor PRE INSTALLATION PREPARATION Continued NOTICE This fireplace is intended for use as supple mental heat Use this fireplace along with your pri mary heating system Do n...

Страница 6: ...nlet 72 inches 182 9cm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum...

Страница 7: ...ng ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination VENTING INSTALLATION INSTRUCTIONS NOTICE Read these instructions completely be fore at...

Страница 8: ...le ends of adjacent pipes Push pipe sec tionstogetherandtwistonesectionclockwiseapproximatelyone quarterturnuntilthesectionsarefullylocked seeFigure8 Note Horizontal runs of vent must be supported eve...

Страница 9: ...ff Position the standoff cap assembly in the center of the 10 3 4 square hole and attach to exterior wall with wood screws provided see Figure 11 The siding standoff must sit flush against the exterio...

Страница 10: ...rt with critical minimum and maximum dimensions which MUST be met IMPORTANT Remember that a horizontal run of venting must have a 1 4 rise for every 12 of run toward the termination Figure 13 Typical...

Страница 11: ...ntallythroughwall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION Recommended Applications Installations...

Страница 12: ...NG INSTALLATION INSTRUCTIONS Installation Planning Cont HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal sys...

Страница 13: ...oom install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all pipe and elbow connections are f...

Страница 14: ...Round High Wind Termination Shown Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 40 max Figure23 VerticalVentingCon...

Страница 15: ...tion Shown Note Install restrictor into inner collar of fireplace as shown 45 Elbow PARTS LISTS FOR VENTING KITS AND COMPONENTS DESA 5 8 Pipe Vent Kits Number Description P58 6 6 Section Double Wall P...

Страница 16: ...Lists for Venting Kits and Components FIREPLACE INSTALLATION Check Gas Type Installing Optional Blower Accessory Model BK Installation Follow all instructions provided in the blower accessory kit 1 A...

Страница 17: ...nnections securely 3 Place the blower against the lower rear wall of the firebox outer wrapperwiththeexhaustportdirectedupwardandthethermodisc positioned up near the fireplace bottom The thermodisc mu...

Страница 18: ...ne LP Only Propane LP Supply Tank External Regulator Vent Pointing Down FIREPLACE INSTALLATION Continued FIREPLACE INSTALLATION Installing Optional Blower Accessory Cont Installing Gas Piping To Firep...

Страница 19: ...e Nipple Tee Joint Sediment Trap Drip Leg Natural From Gas Meter 5 5 W C to 10 5 W C Pressure Propane LP From External Regulator 11 W C to 14 W C Pressure The CSA design certified equipment shutoff va...

Страница 20: ...see Figure 34 for propane LPor Figure 35 for natural gas Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once Pressure Testing Fireplace Gas Conn...

Страница 21: ...before removing glass door or louvers Spring Latch Removing Glass Door If replacement of glass is necessary the entire assembly glass and frame must be replaced If glass is broken wear gloves and tape...

Страница 22: ...ing brick liner This brick liner kit is optional You may purchase brick liner from your local retailer or see Accessories page 37 CAUTION Always handle brick panels with two hands Do not force brick p...

Страница 23: ...ont of firebox bottom in ar eas that are visible only It is not necessary to use all of the lava rock provided NOTICE Do not put lava rock on burner or under burner Placing lava rock on burner will ca...

Страница 24: ...dy to use 5 Close lower louver panel Figure 47 Installing the WRC Remote Receiver Fireplace Receptacle Remote Control Receiver Extension Cord Ignition Module Plug Figure 48 Installing Battery into Bac...

Страница 25: ...flame appears at pilot If lighting the appliance for the first time each season it may take several attempts before the supply gas can reach the pilot and main burners If the appliance will not stay...

Страница 26: ...and remove any dust dirt or other obstructions that will hinder the flow of air BURNER FLAME PATTERN Burner flames will be steady not lifting or floating Flame patterns will be different from unit to...

Страница 27: ...be used CLEANING AND MAINTENANCE CAUTION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING Donotopera...

Страница 28: ...and repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pi lot line 6 Replace control...

Страница 29: ...an material OBSERVED PROBLEM Fireplace produces a clicking ticking noise just after burner is lit or shut off Slightsmokeorodorduringinitialoperation Gas odor even when control knob is in OFF position...

Страница 30: ...atech com 30 ILLUSTRATED PARTS BREAKDOWN Models V36EN A V36EP A VV36ENSB 1 VV36ENHB 1 VV36EPSB 1 VV36EPHB 1 ILLUSTRATED PARTS BREAKDOWN MODELS V36EN A V36EP A VV36ENSB 1 VV36ENHB 1 VV36EPSB 1 VV36EPHB...

Страница 31: ...Bottom Panel Louver Assy 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 109082 01 109082 01 Heat Shield 1 10 108032 01 108032 01 108032 01 Log Set 1 10 1 109128 01...

Страница 32: ...USTRATED PARTS BREAKDOWN Models V36EN A VV36ENSB 1 VV36ENHB 1 V36EP A VV36EPSB 1 VV36EPHB 1 ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V36EN A VV36ENSB 1 VV36ENHB 1 V36EP A VV36EPSB 1 VV36...

Страница 33: ...1107 Screw 10 32 x 1 4 PPH Zinc 4 16 26808 Valve Bracket 1 17 26827 Switch Bracket 1 18 11147 Screw 10 24 x 1 2 PPH Zinc 2 19 11186 Screw 8 32 x 1 Zinc 4 20 14115 Spade Tongue Connector 1 21 14120 Spa...

Страница 34: ...act your local gas supplier TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting If so contact DESA s Customer Service Depart mentat1 866 672 6040 Whencalli...

Страница 35: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Страница 36: ...111253 01D For more information visit www desatech com For more information visit www desatech com 36 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 37: ...FPD36P Filligree Panel Kit Platinum FPD36PB Filligree Panel Kit Polished Brass LOUVER TRIM KIT Rolled Louvers Only Not Shown LT36B Rolled Louver Trim Kit Brushed Brass LT36P Rolled Louver Trim Kit Pla...

Страница 38: ...ansportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE...