www.desatech.com
107068-01K
5
PRODUCT
IDENTIFICATION
Figure 1 - Yellow Flame Vent-Free Gas
Log Heater Shown (Logs May Vary by
Model)
Front
Log
Control Knob
Back Log
Burner
Piezo
Ignitor
Crossover
Log
UNPACKING
CAUTION: Do not remove the
data plates from the grate as-
sembly. The data plates contain
important warranty and safety
information.
1. Remove logs and heater base assembly from
carton.
Note:
Do not pick up heater base as
-
sembly by burners. This could damage heater.
Always handle base assembly by grate.
2. Remove all protective packaging applied to
logs and heater for shipment.
3. Check all items for any shipping damage. If
damaged, promptly inform dealer where you
bought heater.
PRODUCT FEATURES
OpERATION
This heater is clean burning. It requires no outside
venting. There is no heat loss out a vent or up a
chimney. Heat is generated by realistic, dancing
yellow flames. This heater is designed for vent-free
operation with flue damper closed. It has been
tested and approved to ANSI Z21.11.2 standard
for unvented heaters. State and local codes in
some areas prohibit the use of vent-free heaters.
Non-thermostat models may also be operated as
a vented decorative (ANSI Z21.60) product by
opening flue damper.
SAFETY pILOT
This heater has a pilot with an Oxygen Deple
-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free room
heaters. The ODS/pilot shuts off the heater if there
is not enough fresh air.
pIEzO IGNITION SYSTEM
This heater has a piezo ignitor. This system re
-
quires no matches, batteries or other sources to
light heater.
AIR FOR COMbUSTION
AND VENTILATION
WARNING: This heater shall
not be installed in a confined
space or unusually tight con-
struction unless provisions are
provided for adequate combus-
tion and ventilation air. Read the
following instructions to insure
proper fresh air for this and
other fuel-burning appliances
in your home.
Today’s homes are built more energy efficient
than ever. New materials, increased insulation and
new construction methods help reduce heat loss
in homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out
and the warm air in. During heating months, home
owners want their homes as airtight as possible.
While it is good to make your home energy efficient,
your home needs to breathe. Fresh air must enter
your home. All fuel-burning appliances need fresh
air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers and fuel
burning appliances draw air from the house to
operate. You must provide adequate fresh air for
these appliances. This will insure proper venting
of vented fuel-burning appliances.