background image

15

105056

OWNER’S MANUAL

REPLACEMENT
PARTS

Note:

 Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) contact DESA International’s Tech-
nical Service Department at 1-800-323-
5190.

When calling, have ready

• your name

• your address

• model number of your CO2 generator

• how appliance was malfunctioning

• type of gas used (propane/LP or natural

gas)

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) contact DESA International’s Parts
Department at 1-800-972-7879 for referral
information.

When calling, have ready

• model number of your CO2 generator

• the replacement part number

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-800-323-5190.

SPECIFICATIONS

RP30E-CAN

RN30E-CAN

Btu (Variable)

15,000/30,000

15,000/30,000

Type Gas

Propane/LP Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

3" W.C.

Inlet Gas Pressure (inches of water)

Maximum

14"

10.5"

Minimum

11"

4"

Dimensions, Inches (H x W x D)

Appliance

23.5 x 25.9 x 8.0

23.5 x 25.9 x 8.0

Carton

26 x 27.75 x 9.63

26 x 27.75 x 9.63

Weight (pounds)

Appliance

30

30

Shipping

35

35

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• appliance will not produce maximum CO2

• (Propane Only) propane/LP gas supply

may be low

When Gas Quality Is Bad

• pilot will not stay lit

• burner will produce flames and soot

• appliance will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.

SERVICE HINTS

ACCESSORIES

Purchase this CO2 generator accessory from
your local dealer. If they can not supply this
accessory contact DESA International’s Parts
Department at 1-800-972-7879 for referral
information. You can also write to the ad-
dress listed on the back page of this manual.

MANUAL SHUT OFF VALVE -
GA5010

Manual shutoff valve with 1/8" NPT tap.

Содержание RN30E-CAN

Страница 1: ...reference BLUE FLAME VENT FREE PROPANE AND NATURAL GAS GREENHOUSE CO2 GENERATOR OWNER S OPERATION AND INSTALLATION MANUAL WARNING This is an unvented gas firedappliance Itusesair oxygen from the spac...

Страница 2: ...plate This appliance is not convertible for use with other gases 2 Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors 3 If you smell gas shut off gas s...

Страница 3: ...ADEQUATE VENTILATION Unconfined Space Can Gas Code B 149 1 and 2 M95 Section 6 3 3 states An appliance installed for the production of carbon dioxide in a green house may take its combustion air from...

Страница 4: ...ace 50 cu ft 51 2 or 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space CO2 generator ______________________ Btu Hr Gas water heater _____________...

Страница 5: ...n or Canadian Gas Code B 149 1 and 2 M95 Section 7 2 and 7 3 and or appli cable local codes for required size of venti lation grills or ducts WARNING Rework work sheet adding the space of the adjoinin...

Страница 6: ...ction and service where strong wind gusts from an open door or ventilator can not blow directly into appliance 16 3 4 Figure4 MountingClearancesAsViewed From Front of Appliance INSTALLATION NOTICE A q...

Страница 7: ...d walls do not pop open wings 5 Place mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anchors 7 Tighten scr...

Страница 8: ...Only Never connect appliance directly to the propane LP supply This appliance requires an external regulator notsupplied Installthe external regulator between the applianceandpropane LPsupply Figure 1...

Страница 9: ...s joints Bubbles form ing show a leak 5 Correct all leaks at once TestPressuresEqualToorLessThan 1 2 PSIG 1 Close manual shutoff valve see Fig ure 14 2 Pressurize supply piping system by ei therusingc...

Страница 10: ...ing Instructions 3 With control knob pressed in strike match Hold match to pilot until pi lot lights 4 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release contro...

Страница 11: ...Figure21showsanincorrectburner flame pattern The incorrect burner flame patternshowsyellowtippingoftheflame It also shows the flame higher than 1 2 the heat shield height Ifburnerflamepatternisincorre...

Страница 12: ...ly open 4 Thermocoupleconnectionlooseatcon trol valve 5 Pilotflamenottouchingthermocouple which allows thermocouple to cool causing pilot flame to go out This problemcouldbecausedbyoneorboth of the fo...

Страница 13: ...ir passageways on appliance blocked 4 Dirtyorpartiallycloggedburnerorifice REMEDY 1 Contact local gas company 2 Clean burner see Cleaning and Main tenance page 11 or replace burner orifice 1 Clean bur...

Страница 14: ...essure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at...

Страница 15: ...nternational s Technical Service Department at 1 800 323 5190 SPECIFICATIONS RP30E CAN RN30E CAN Btu Variable 15 000 30 000 15 000 30 000 Type Gas Propane LP Only Natural Only Ignition Piezo Piezo Pre...

Страница 16: ...UE FLAME VENT FREE PROPANE LP AND NATURAL GAS GREENHOUSE CO2 GENERATOR 1 2 4 5 6 6 7 8 8 9 10 11 12 15 17 19 21 22 23 20 26 25 18 14 16 24 3 13 ODS PILOT 10 1 10 2 ILLUSTRATED PARTS BREAKDOWN RP30E CA...

Страница 17: ...01 Thermocouple 1 10 2 098594 01 Ignitor Electrode 1 11 103447 01 Burner 1 12 099387 05 3 16 Pilot Tubing 1 13 103845 03 Injector L P 1 103845 04 Injector N G 1 14 099066 01 Mounting Bracket 1 15 099...

Страница 18: ...are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installatio...

Отзывы: