background image

11

105056

OWNER’S MANUAL

1/2 HEAT SHIELD
HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

INSPECTING
BURNER

Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pat-
tern. Figure 19 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the appliance will shut
down.

If pilot flame pattern is incorrect, as shown
in Figure 19

• turn appliance off (see To Turn Off Gas

to Appliance, page 10)

• see Troubleshooting, pages 12 through 14

Figure 18 - Correct Pilot Flame Pattern

Figure 19 - Incorrect Pilot Flame Pattern

NOTICE: Do not mistake orange
flames with yellow tipping. Dirt
or other fine particles enter the
appliance and burn causing brief
patches of orange flame.

Thermocouple

Pilot Burner

Pilot Burner

Thermocouple

Figure 20 - Correct Burner Flame Pattern

Figure 21 - Incorrect Burner Flame Pattern

BURNER FLAME PATTERN

Figure 20 shows a correct burner flame
pattern. Figure 21 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than 1/2 the
heat shield height.

If burner flame pattern is incorrect, as shown
in Figure 21

• turn appliance off (see To Turn Off Gas

to Appliance, page 10).

• see Troubleshooting, pages 12 through 14

 WARNING: If yellow tipping

occurs, your CO2 generator could
produce increased levels of car-
bon monoxide. If burner flame
pattern shows yellow tipping, fol-
low instructions at bottom of this
page.

Yellow
Tipping

CLEANING AND
MAINTENANCE

 WARNING: Turn off appliance

and let cool before cleaning.

 CAUTION: You must keep con-

trol areas, burner, and circulating
air passageways of appliance
clean. Inspect these areas of ap-
pliance before each use. Have
CO2 generator inspected yearly
by a qualified service person. Ap-
pliance may need more frequent
cleaning due to excessive saw-
dust, cobwebs, etc.

ODS/PILOT AND BURNER

• Use a vacuum cleaner, pressurized air, or

small, soft bristled brush to clean.

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air

to clean.

Exterior

• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi-
net to remove dust.

CORRECT FLAME PATTERN

AT HIGH POSITION

1/2 HEAT SHIELD
HEIGHT

Содержание RN30E-CAN

Страница 1: ...reference BLUE FLAME VENT FREE PROPANE AND NATURAL GAS GREENHOUSE CO2 GENERATOR OWNER S OPERATION AND INSTALLATION MANUAL WARNING This is an unvented gas firedappliance Itusesair oxygen from the spac...

Страница 2: ...plate This appliance is not convertible for use with other gases 2 Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors 3 If you smell gas shut off gas s...

Страница 3: ...ADEQUATE VENTILATION Unconfined Space Can Gas Code B 149 1 and 2 M95 Section 6 3 3 states An appliance installed for the production of carbon dioxide in a green house may take its combustion air from...

Страница 4: ...ace 50 cu ft 51 2 or 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space CO2 generator ______________________ Btu Hr Gas water heater _____________...

Страница 5: ...n or Canadian Gas Code B 149 1 and 2 M95 Section 7 2 and 7 3 and or appli cable local codes for required size of venti lation grills or ducts WARNING Rework work sheet adding the space of the adjoinin...

Страница 6: ...ction and service where strong wind gusts from an open door or ventilator can not blow directly into appliance 16 3 4 Figure4 MountingClearancesAsViewed From Front of Appliance INSTALLATION NOTICE A q...

Страница 7: ...d walls do not pop open wings 5 Place mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anchors 7 Tighten scr...

Страница 8: ...Only Never connect appliance directly to the propane LP supply This appliance requires an external regulator notsupplied Installthe external regulator between the applianceandpropane LPsupply Figure 1...

Страница 9: ...s joints Bubbles form ing show a leak 5 Correct all leaks at once TestPressuresEqualToorLessThan 1 2 PSIG 1 Close manual shutoff valve see Fig ure 14 2 Pressurize supply piping system by ei therusingc...

Страница 10: ...ing Instructions 3 With control knob pressed in strike match Hold match to pilot until pi lot lights 4 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release contro...

Страница 11: ...Figure21showsanincorrectburner flame pattern The incorrect burner flame patternshowsyellowtippingoftheflame It also shows the flame higher than 1 2 the heat shield height Ifburnerflamepatternisincorre...

Страница 12: ...ly open 4 Thermocoupleconnectionlooseatcon trol valve 5 Pilotflamenottouchingthermocouple which allows thermocouple to cool causing pilot flame to go out This problemcouldbecausedbyoneorboth of the fo...

Страница 13: ...ir passageways on appliance blocked 4 Dirtyorpartiallycloggedburnerorifice REMEDY 1 Contact local gas company 2 Clean burner see Cleaning and Main tenance page 11 or replace burner orifice 1 Clean bur...

Страница 14: ...essure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at...

Страница 15: ...nternational s Technical Service Department at 1 800 323 5190 SPECIFICATIONS RP30E CAN RN30E CAN Btu Variable 15 000 30 000 15 000 30 000 Type Gas Propane LP Only Natural Only Ignition Piezo Piezo Pre...

Страница 16: ...UE FLAME VENT FREE PROPANE LP AND NATURAL GAS GREENHOUSE CO2 GENERATOR 1 2 4 5 6 6 7 8 8 9 10 11 12 15 17 19 21 22 23 20 26 25 18 14 16 24 3 13 ODS PILOT 10 1 10 2 ILLUSTRATED PARTS BREAKDOWN RP30E CA...

Страница 17: ...01 Thermocouple 1 10 2 098594 01 Ignitor Electrode 1 11 103447 01 Burner 1 12 099387 05 3 16 Pilot Tubing 1 13 103845 03 Injector L P 1 103845 04 Injector N G 1 14 099066 01 Mounting Bracket 1 15 099...

Страница 18: ...are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installatio...

Отзывы: