background image

www.desatech.com

115423-01A

8

REASSEMBLY POINTS

Because  this  is  an  outdoor  product  where  the 

control of water is important, the following steps 

for assembly  must be followed.
1.  The closed cell foam gasket must seal the hex 

shaped pan to the inside of the plastic housing 

(see Figure 8). The seal is to be completely 

even in the corners of joined parts.

2.  The tubular heating element rubber sealing 

washers must be against the top surface of the 

steel pan and under the brass flat washers as 

shown in Figure 9. Nuts on opposite side of pan 

must be tightened 1/2 turn past finger tight.

3.  Apply a SMALL drop of thread locking seal-

ant (rated to 300° F, such as Loctite Thread  

Locker  Blue)  to  each  of  the  thermal  reset 

switch  mounting  screws  (see  Figure  10). 

Torque screws to 6 to 9 inch-pounds.

4.  The tip switch cover must isolate tip switch 

from metal base as shown in Figure 11.

5.  To complete grounding of heater, all ground 

wires must be fixed with screws as originally 

assembled by the manufacturer. Additionally, 

internal tooth washers must be against the steel 

pan and under nuts as shown in Figure 12, for 

the tubular heating element.

6.  No wires should be seen through openings in 

bottom of heater (see Figure 13).

Figure 8 - Foam Gasket

Figure 9 - Tubular Heating Element 

Sealing Washers

Figure 10 - Thermal Reset Switch 

Mounting Screws

Figure 11 - Tip Switch Cover

Figure 12 - Grounding of the Tubular 

Heating Element

Figure 13 - Air Openings in Bottom of 

Heater

Brass Flat 
Washer

Rubber 
Sealing 
Washer

Содержание PD15EA

Страница 1: ...erence For more information visit www desatech com MODELS PD15EA PG15EA PL15EA AND PV15EA 1500 WATT 120V 60HZ 12 5 AMPS OUTDOOR ELECTRIC PATIO TABLE UMBRELLA STAND AND FOOT WARMER SERVICE MANUAL TABLE OF CONTENTS Safety Information 2 Pre Operating Instructions 3 General Information 4 Product Identification 5 Installation 5 Operation 5 Cleaning 5 Wiring Diagram 5 Safety Requirements 6 Cautions 6 All...

Страница 2: ...ug product after use 13 When unplugging be sure to pull by the plug and not the cord 14 Keep electrical plug dry and off of wet surfaces 15 Do not place or store where product can fall or be pulled into swimming pool or body of water If product falls into water unplug immediately DO NOT REACH INTO WATER If water is above the air intakes see Figure 3 page 4 or product is totally immersed in water d...

Страница 3: ...er or birth defects or other reproductive harm PRE OPERATING INSTRUCTIONS GROUND FAULT INTERRUPTER Since 1971 the National Electric Code NEC has required Ground Fault Circuit Interrupter devices on all outdoor circuits Ifyourresidencewasbuiltbefore1971 checkwith a qualified electrician to determine if a Ground Fault Circuit Interrupter protector exists Do not use this product if the circuit does no...

Страница 4: ...ise which have not been covered If such problems arise please call the Technical Service Departmentʼs number 1 866 672 6040 or visit our website at www desatech com to address these technical problem areas If you need assistance for ordering parts billing questions etc you should contact 1 866 672 6040 SERVICE PREPARATION A clean work area at the start of each job is essen tial for efficient servic...

Страница 5: ...Follow all local ordinances and codes when using this product 1 Push lighted ON OFF switch 2 The power light will remain lit during operation 3 Stay back from product until all water or debris has blown clear 4 Product will warm in a few minutes CLEANING DURING SEASON CARE Always unplug the product before moving or cleaning 1 Do not disassemble Carefully wipe the exte rior of unit with a soft damp...

Страница 6: ...rior of plastic shroud and inside pole receiver for cracks Replace shroud if cracks are found 2 Examine cover of on off switch for cracks Replace switch if cracks are found A C Air To Be Heated Heated Air D E B Figure 4 System Operation TROUBLESHOOTING CAUTION Risk of electric shock If your product fails to operate 1 Make sure the electrical outlet GFCI or circuit breaker and extension cord is wor...

Страница 7: ...il If the resistance is not approximately 6 0 to 6 4 ohms at 73 F the motor is defective and should be replaced Note Resistances may vary due to motor temperature Figure 6 Testing Motor OBSERVED FAULT Motor starts and runs but cool air is felt Does tubular heating element heat up No Yes WARNING WARNING Hot Surface Hot Surface 1 Look for defective 3 Check for blocked tubular heating air intake open...

Страница 8: ...0 F such as Loctite Thread Locker Blue to each of the thermal reset switch mounting screws see Figure 10 Torque screws to 6 to 9 inch pounds 4 The tip switch cover must isolate tip switch from metal base as shown in Figure 11 5 To complete grounding of heater all ground wires must be fixed with screws as originally assembled by the manufacturer Additionally internal tooth washers must be against th...

Страница 9: ... on flat of shaft see Figure 15 9 Heater is equipped with heat reflective tape If loose or damaged replace tape as shown in Figures 16 and 17 Tape edge should touch top of louver openings REASSEMBLY POINTS Continued Figure 14 Heating Element and Bracket Figure 15 Fan and Motor Figure 16 Reflective Tape and Louvers Figure 17 Reflective Tape on All Louvers Motor Shaft Back of and Flat of Motor Shaft Fan...

Страница 10: ...tech com 115423 01A 10 ILLUSTRATED PARTS BREAKDOWN 19 1 7 28 14 16 9 8 2 17 18 27 26 15 Requires Loctite Thread Locker Blue 6 3 22 23 20 13 11 10 21 2 12 24 25 Steel Nut Brass Washer Rubber Seal Bottom View 5 4 ...

Страница 11: ...103457 01 Button Plug 1 13 114679 01 Screen Guard Kit 1 14 114025 01 Manual Reset Limit Switch 1 15 M10908 2 Screw 6 32 x 3 8 Hex Head 2 16 107729 01 Tip Switch 1 17 097968 07 Screw 4 40 x 3 4 Hex Head 2 18 097384 04 Captive Washer Nut 2 19 Mounting Pan Kit 1 20 113558 01 On Off Switch 1 21 097785 10 Gasket Seal 1 22 113578 01 Thumb Screw 1 4 20 x 1 1 23 113577 01 Nut 1 4 20 Weld 1 24 113200 01 Ti...

Страница 12: ...115423 01 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com 115423 01 Rev A 10 04 NOT A UPC ...

Отзывы: