background image

12

105986

VENT-FREE PROPANE/LP GAS STOVE HEATER

SUN VALLEY STOVE COMPANY

For more information, visit www.desatech.com

ON

POSIT

O

POS

Tee
Joint

Pipe
Nipple

Cap

3" Minimum

Sediment
Trap

Gas
Regulator

From External
Regulator (11"
W.C.** to 14"
W.C. Pressure)

CSA/AGA Design-Certified Equipment
Shutoff Valve With 1/8" NPT Tap*

Approved Flexible
Gas Hose (if allowed
by local codes)

Figure 20 - Gas Connection (MSVFBP Series)

* Purchase the optional CSA/AGA design-certified equipment shutoff valve from your

dealer. See Accessories, page 23.

** Minimum inlet pressure for purpose of input adjustment.

 CAUTION: Avoid damage to

regulator. Hold gas regulator with
wrench when connecting it to gas
piping and/or fittings.

 CAUTION: Use pipe joint seal-

ant that is resistant to liquid pe-
troleum (LP) gas.

Install sediment trap in supply line as shown
in Figure 19, page 11 and Figure 20. Locate
sediment trap where it is within reach for
cleaning. Locate sediment trap where trapped
matter is not likely to freeze. A sediment
trap traps moisture and contaminants. This
keeps them from going into heater controls.
If sediment trap is not installed or is in-
stalled wrong, heater may not run properly.

INSTALLATION

Continued

 WARNING: Never use an open

flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. Bubbles forming show
a leak. Correct all leaks at once.

 WARNING: Test all gas pip-

ing and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.

CHECKING GAS
CONNECTIONS

Pressure Testing Gas Supply
Piping System

Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)

1.

Disconnect appliance with its appli-
ance main gas valve (control valve)
and equipment shutoff valve from gas
supply piping system. Pressures in ex-
cess of 1/2 psig will damage heater
regulator.

2.

Cap off open end of gas pipe where
equipment shutoff valve was con-
nected.

3.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

4.

Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

6.

Reconnect heater and equipment
shutoff valve to gas supply. Check re-
connected fittings for leaks.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)

1.

Close equipment shutoff valve (see Fig-
ure 21).

2.

Pressurize supply piping system by either
using compressed air or opening propane/
LP supply tank valve.

3.

Check all joints from gas meter to equip-
ment shutoff valve (see Figure 22). Ap-
ply mixture of liquid soap and water to
gas joints. Bubbles forming show a leak.

4.

Correct all leaks at once.

Pressure Testing Heater Gas
Connections

1.

Open equipment shutoff valve (see Fig-
ure 21).

2.

Open propane/LP supply tank valve.

3.

Make sure control knob of heater is in
the OFF position.

4.

Check all joints from equipment shutoff
valve to control valve (see Figure 22).
Apply mixture of liquid soap and wa-
ter to gas joints. Bubbles forming show
a leak.

5.

Correct all leaks at once.

6.

Light heater (see Operating Heater,
pages 14 through 17). Check all other
internal joints for leaks.

7.

Turn off heater (see To Turn Off Gas to
Appliance
, remote-ready models, page
15, variable manual models, page 16).

Figure 21- Equipment Shutoff Valve

Closed

Equipment
Shutoff
Valve

Open

Figure 22 - Checking Gas Joints

Control Valve
Location

Propane/LP
Supply Tank

Equipment Shutoff Valve

 CAUTION: Make sure exter-

nal regulator has been installed
between propane/LP supply and
heater. See guidelines under

 Con-

necting to Gas Supply, page 11.

Содержание MSVFBP

Страница 1: ...WARNING The MSVFBP R series vent free gaslogheaterisonlyapprovedforuseinthe Sun Valley MC series and MCH P series cast iron stove models Indicates Color Suffix Designation Save this manual for future...

Страница 2: ...heater Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable material on or near the appliance Never pl...

Страница 3: ...oss out a vent or up a chimney Heat is generated by realistic dancingyellowflames Thisheater is designed for vent free operation State and local codes in some areas prohibit the use of vent free heate...

Страница 4: ...ater vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking o...

Страница 5: ...________Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual...

Страница 6: ...power vent Figure 2 Ventilation Air from Inside Building VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining un...

Страница 7: ...e is a freestanding unit designed to set directly on the floor Do not place stove directly on carpeting vinyl tile or any com bustiblematerialotherthanwood Thestove mustsetonametalorwoodpanelextending...

Страница 8: ...ee Figure 5 Use an adjustable wrench or a 10 mm socket Remove six 6 bolts and washers Keep bolts and washers to reattach back panel later 5 Remove all contents from inside stove cavity Contents includ...

Страница 9: ...stepbolt Tightenstepboltuntilsnug Make sure door moves freely 11 Install door catch bolt M8 x 1 25 55mm with two M8 hex nuts into threaded hole on stove body see Fig ure 8 page 8 Use an adjustable wre...

Страница 10: ...center of heater base Log will fit securely on base IMPORTANT Make sure log does not cover any burner ports and does not touch the stove cavity see Figure 16 9 Fasten back panel to stove with six 6 M...

Страница 11: ...uhave the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench An CSA AGA design certified...

Страница 12: ...off valve from gas supply piping system Pressures in ex cess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where equipment shutoff valve was con nected 3 Pressurize supply pi...

Страница 13: ...circulation Avoid heat sources such as lamps direct sun light fireplace or heat and air condi tioning ducts WARNING Do not connect this thermostat to a power source Electrical shock and or fire hazard...

Страница 14: ...or If you smell gas STOP Follow B in the safety in formation column 1 If you don t smell gas go to the next step 6 Press in and turn control knob coun terclockwise to the PILOT position Press in contr...

Страница 15: ...operation follow in structionsuppliedwiththermostatacces sory GWMT1 For wall switch operation follow instructions supplied with GWMS2 Figure 28 Setting the Remote Selector Switch Control Knob and Fla...

Страница 16: ...to vent smell This will only last a few hours LIGHTING INSTRUCTIONS MSVFBP VARIABLE MANUAL CONTROL MODELS Figure 30 Control Knob and Ignitor Button Location Control Knob Ignitor Button Figure 31 Pilot...

Страница 17: ...ure 34 Correct Pilot Flame Pattern Figure 35 Incorrect Pilot Flame Pattern BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the burner entrance These holes may...

Страница 18: ...ilot assembly clean and free of dustanddirt Tocleanthesepartswerecom mend using compressed air no greater than 30 PSI Your local computer store hard ware store or home center may carry com pressed air...

Страница 19: ...REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace piezo ignitor 6 Replace piezo i...

Страница 20: ...pro pane LP gas company 3 Observe minimum installation clear ances see page 7 4 Clean burner see Cleaning and Mainte nance page 18 or replace burner orifice 1 Properly locate logs see Installing Gas L...

Страница 21: ...cking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMED...

Страница 22: ...ur heater the replacement part number SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition heater will not produce specified heat When Gas Quality Is B...

Страница 23: ...an turn the gas log heater on and off without ever leaving the comfort of your easy chair RECEIVER AND HAND HELD REMOTE CONTROL KIT GHRC SERIES For remote ready models Allows the gas log heater to be...

Страница 24: ...OVE HEATER SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN MSVFBPR O F F P I L O T O N H I L O H I L O O F F P I L O T O N 17 17 18 19 22 15 14 16 13 1...

Страница 25: ...1 7 099056 19 Burner Orifice Injector 1 8 102980 01 Burner 1 9 099387 13 Pilot Tube 1 10 103781 02 Gas Control Valve 1 11 103345 02 Lower Bracket 1 12 M11084 38 Screw 8 x 38 7 13 104383 02CK Painted...

Страница 26: ...T FREE PROPANE LP GAS STOVE HEATER SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN MSVFBP 20 7 20 20 5 8 15 16 18 22 20 21 17 19 18 3 9 12 1 10 11 6 20...

Страница 27: ...or 1 8 102798 01 Inlet Tube 1 9 102779 04 Outlet Burner Tube 1 10 099056 19 Burner Orifice Injector 1 11 102843 01 Burner Clip 1 12 102980 01 Burner 1 13 102568 08 Control Valve 1 14 098508 01 Valve R...

Страница 28: ...E LP GAS STOVE HEATER SUN VALLEY STOVE COMPANY For more information visit www desatech com 1R 1C 1L 5 8 8 7 4 6 5 5 7 1 7 2 5 4 7 3 2 3 ILLUSTRATED PARTS BREAKDOWN SUN VALLEY STOVE MC SERIES Indicates...

Страница 29: ...lain Enamel Almond 4 Total Per Stove 1 104175 14 One Leg Porcelain Enamel Green 4 Total Per Stove 1 104175 15 One Leg Porcelain Enamel Red 4 Total Per Stove 1 6 104176 01 Leg Leveler bolt M8 x 1 25 55...

Страница 30: ...LP GAS STOVE HEATER SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN SUN VALLEY STOVE MCH P SERIES HEPPLEWHITE STOVE DESIGN 2 9 11 5 4 10 8 6 13 14 12 1...

Страница 31: ...ft Rear Leg Metallic Black 1 104175 31 Left Rear Leg Porcelain Enamel Black 1 104175 32 Left Rear Leg Porcelain Enamel Navy 1 104175 33 Left Rear Leg Porcelain Enamel Almond 1 104175 34 Left Rear Leg...

Страница 32: ...ctive heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXP...

Отзывы: