4
Fig.2. Furnace controller –group of conductors
7. Installation of the device
-
during the installation of the device, meet all the local regulations, including the regulations
referring to the national and European standards
-
place the furnace on a flat concrete ground
-
level the device. In order to check whether the heater is levelled, place the furnace pan in the
lower part of the combustion chamber and pour a small amount of diesel oil on it. The oil should
spread accurately in the middle of the pan.
-
mount the stabiliser on the pipe coming out from the combustion chamber in order to ensure
stable draught during the heater operation.
-
in order to ensure the optimal draught, install a vertical chimney pipe (
not made of aluminium
)
which is at least 6 meters long, smooth, resistant to high temperature
-
check the leakproofness of all connections, in case of emergency, use the insulation tape for the
purpose of sealing them
-
make sure that the combustion pan is placed in the central part of the combustion chamber
-
place the top ring inside the combustion chamber – the edging in the middle of the ring is placed
upwards, - and mount an afterburner cylinder on it (hot air pipe)
-
check the mains voltage (220-240V/50Hz) and connect the furnace to power supply, neither the
fan nor the pump should be started as the furnace has not been switched on yet and no heat has
been produced.
-
maintain a safe distance from inflammable materials
The air exhaust fans operating in the same room or space as the device may introduce disturbances.
Assembly of the chimney pipe
In order to ensure proper burning, it is necessary to provide the properly made chimney installation. The
following recommendations must be met while providing this installation:
-
minimal pipe diameter: 150mm
-
check the leakproofness of connections between the chimney elements
-
minimal chimney height: 6m
-
the section of the chimney inside the chimney should be insulated (dual wall)
-
the wind should freely blow around the chimney outlet from all directions (the end of the
chimney pipe should be above the roof top)
WA 33 controller
Furnace thermnostat
Safety thermnostat (STB)
Overflow fuse
Fan
Pump
Содержание Master WA 33
Страница 1: ...KOTEL NA SMĚSI UPOTŘEBENÝCH OLEJŮ WA 33 NÁVOD K OBSLUZE ...
Страница 15: ...SOOJENDUS SEADE UNIVERSAAL KÜTTEÕLI PEAL WA 33 KASUTAMISE JUHEND 1 ...
Страница 29: ...1 WA 33 UNIVERSAL OIL HEATER OPERATING MANUAL aryjnąależy dokładn 1 Przeznaczenie ...
Страница 43: ...UNIVERSĀLĀS EĻĻAS SILDĪTĀJS WA 33 LIETOŠANAS INSTRUKCIJA 1 ...
Страница 71: ...1 НАГРЕВАТЕЛЬ НА УНИВЕРСАЛЬНОМ МАСЛЕ МОДЕЛЬ WA 33 ИНСТРУКЦИЯ ЭКСПЛУАТАЦИИ ...