OBSERVED PROBLEM

Pilot  lights  but  flame  goes 

out  when  control  knob  is 
released

Burner  does  not  light  after 
pilot is lit

Delayed ignition burner

Burner  backfiring  during 
combustion

Slight  smoke  or  odor  during 
initial operation

REMEDY

1. Press in gas control knob 

fully

2. After pilot lights, keep gas 

control knob pressed in 30 
seconds

3. Fully open equipment shut-

off valve

4. A) Contact local natural or 

propane/LP gas company

  B) Clean pilot (see 

Clean-

ing  and  Maintenance, 

page  31)  or  replace  pilot 
assembly

5. Hand  tighten  until  snug, 

then tighten 1/4 turn more

6. Replace pilot assembly
7. Replace control valve

1. Clean burner (see 

Cleaning 

and Maintenance

, page 31) 

or replace burner orifice

2. Contact  local  propane/LP 

or natural gas company

3. Reconnect leads to TP and 

TPTH terminals on control 
valve

4. Replace thermopile

1. Contact  local  propane/LP 

or natural gas company

2. Clean burner (see 

Cleaning 

and Maintenance

, page 31) 

or replace burner orifice

1. Clean burner (see 

Cleaning 

and Maintenance

, page 31) 

or replace burner orifice

2. Replace damaged burner
3. Replace gas control

1. Problem  will  stop  after  a 

few hours of operation

TRoUbLeShooTING

Continued

pOSSIBLE CAUSE

1. Gas control knob not fully 

pressed in

2. Gas  control  knob  not 

pressed in long enough

3. Equipment  shutoff  valve 

not fully open

4. Pilot  flame  not  touching 

thermocouple,  which  al-
lows thermocouple to cool, 

causing  pilot  flame  to  go 

out.  This  problem  could 
be caused by one or both 
of the following:

  A) Low gas pressure
  B) Dirty or partially clogged 

pilot

5. Thermocouple connection 

loose at control valve

6. Thermocouple damaged
7. Control valve damaged

1. Burner orifice clogged

2. Inlet  gas  pressure  is  too 

low

3. Thermopile  leads  discon-

nected or improperly con-
nected

4. Thermopile is defective

1. Manifold  pressure  is  too 

low

2. Burner  porting  or  orifice 

clogged

 

1. Burner orifice is clogged or 

damaged

2. Damaged burner
3. Gas regulator defective

1. Residues  from  manufac-

turing processes and logs 
curing

Содержание Ironhaus Selway IKC36N Series

Страница 1: ...e Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas suppl...

Страница 2: ...dealer and or shipper immediately if damaged and document with photos etc 2 Remove glass or mesh door s from the frame and set aside in a safe place throughout the construction process 3 Reinstall the...

Страница 3: ...properly Get fresh air at once Have fireplace serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those unde...

Страница 4: ...ly a qualified service person should install service or re pair this fireplace Have fireplace inspected annually by a qualified service person 5 You must keep control compartments burners and circulat...

Страница 5: ...Only the blower requires electricity if in stalled and if you plan to install the blower at a later date do not forget to wire the outlet at the bottom of the fireplace when framing A piezo ignitor an...

Страница 6: ...ese spacers can be placed directly against wall or framing material See framing details on page 7 If you plan on installing a television or enter tainment center recessed above your fire place it is r...

Страница 7: ...cessories for this fireplace see Accessories on page 42 If you are using a separate combustible mantel piece refer to Figure 6 for proper installation height You can install noncombustible mantels at...

Страница 8: ...30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m hori...

Страница 9: ...ust terminate on the out side of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance Adirect vent appliance must have its own venti...

Страница 10: ...le ends of adjacent pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until sections are fully locked see Figure 8 Note Horizontal runs of vent must be s...

Страница 11: ...with wood screws provided see Figure 11 Siding standoff must sit flush against exterior fascia material 7 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before conne...

Страница 12: ...on is required NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cause excessive temperatures which cou...

Страница 13: ...LLATION Recommended Applications Installations requiring a vertical rise on building exterior Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are avail...

Страница 14: ...irements for a horizontal system using two 90 elbows Figure 18 Horizontal Termination Configuration for Venting Using Two 90 Elbows with Termination at 90 with Fireplace 45 Elbow Venting with Two 90 E...

Страница 15: ...g joists If area above ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insulation from falling into required clear ance space If area above ceiling is a liv...

Страница 16: ...igure 22 Vertical Venting Configuration Using One 90 Elbow Vertical Round High Wind Termination Shown 45 Elbow Note Install restrictor into inner collar of fireplace as shown similar factors may cause...

Страница 17: ...been tested and approved for elevations from 0 2000 feet USA and elevations from 0 4500 feet Canada Fireplaces for High Altitude models ending in HA are for installation above 4000 feet only These fi...

Страница 18: ...torm Collar Roof Flashing 0 12 6 12 26 Screws VKC 58 Corner Vent Kit Galvanized Includes 45 Elbow 7 12 Adjustable Pipe Wall Firestop Horizontal Termination 6 Pipe 90 Elbow 18 Screws HHTK 58 High Wind...

Страница 19: ...t directed upward Blower will fit inside back opening and be held in position against back wall by magnets see Figure 26 4 Be certain that all wire terminals are securely attached to terminals on blow...

Страница 20: ...al Note Power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connec tions DO NOT trim excessive length away Enable just enough to make...

Страница 21: ...an Switch Fan Switch N O Green White On 110 115 V A C Blower Motor Black Off 1 2 Black Installing Gas Piping to Fireplace Location WARNING A qualified service person must connect fireplace to gas supp...

Страница 22: ...shown in Figure 32 Locate sediment trap drip leg where it is within reach for cleaning Install in piping sys tem between fuel supply and fireplace Locate sediment trap drip leg where trapped matter is...

Страница 23: ...eplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid...

Страница 24: ...If wires are not connected as shown switch will not work 2 Route 25 ft wire through openings pro vided on sides of burner system to a con venient location to mount your switch 3 Connect one bare wire...

Страница 25: ...removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING If fireplace has been running turn off and un plug fireplace Let cool before removing inner glass doo...

Страница 26: ...1 and 2 1 Pull ember material apart into pieces no larger than a dime Place these pieces loosely and sparingly directly onto ex posed front section of burner see Figure 44 This will create the glowing...

Страница 27: ...in step 6 for left brick panel 11 Replace deflector shield using screws removed in step 7 12 Using screws removed in step 6 replace plenum and attach to burner 13 Carefully replace ember pod and log...

Страница 28: ...mediately call your service technician or gas supplier If pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 9 Turn on all el...

Страница 29: ...rmostatic Mode 1 Press the POWER and LOCK buttons together to turn on the hand held remote control 2 Press AUTO button to select this mode 3 Set the desired room temperature by pressing the TEMP or bu...

Страница 30: ...sachildsafetyfeaturetopreventacciden tal ignition of the fireplace the receiver ON OFF REMOTE switch should be in the OFF position Auto Shutoff Feature 1 If the average room temperature reaches a rang...

Страница 31: ...before each use Have fireplace inspected yearly by a qualified service person Fireplace may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc GLASS Doors...

Страница 32: ...cleaned with compressed air to remove dust dirt or lint Use a vacuum cleaner or small soft bristled brush to remove excess dust dirt or lint Logs If you remove logs for cleaning refer to Installing La...

Страница 33: ...as lines when in stalled 5 Depleted gas supply pro pane LP models only 6 Pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any...

Страница 34: ...l gas company 2 Clean burner see Cleaning and Maintenance page 31 or replace burner orifice 1 Clean burner see Cleaning and Maintenance page 31 or replace burner orifice 2 Replace damaged burner 3 Rep...

Страница 35: ...oval 2 Check vent configuration specifications see Venting Installation page 9 1 This is normal If noise is excessive contact qualified service person 1 Replace 9 volt batteries in receiver and hand h...

Страница 36: ...n 1 Gas leak See Warning statement above 2 Control valve defective 1 Gas leak See Warning statement above OBSERVED PROBLEM Fireplace produces un wanted odors Fireplace shuts off in use Gas odor even w...

Страница 37: ...this product If they can t supply original replacement part s call DESA Heating LLC at 1 866 672 6040 When calling DESA Heating LLC have ready your name your address model and serial numbers of your h...

Страница 38: ...www ironhaus com or www desatech com 121333 01A 38 Parts Models IKc36N Series 6 7 20 17 18 13 2 12 19 8 1 4 11 9 3 5 10 14 21 23 22 15 16...

Страница 39: ...1 02 Bottom Louver Assembly 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 Heat Shield 1 10 116541 01 Burner Assembly NG see page 40 1 116211 05 Burner Assembly fo...

Страница 40: ...www ironhaus com or www desatech com 121333 01A 40 PARTS Burner assembly models IKc36N Series 7 15 10 12 1 12 2 3 13 9 11 21 22 TPTH TP TH 6 12 14 18 17 17 18 19 20 16 14 8 4 5...

Страница 41: ...32 x 3 8 Zinc 2 8 116572 01 Tubing Assembly 1 9 111288 02 Flex Gas Line 1 10 108084 02 Pilot Assembly NG 1 108084 05 Pilot Assembly HA Models 1 11 14389 Natural Gas Valve 1 117370 01 Natural Gas High...

Страница 42: ...ed in this manual Flexible gas Line connector CIK For all models Propane natural gas conversion kit IMPORTANT NOT to be used for High Alti tude HA Models PCDM 36KC Propane LP Gas Conver sion Kit Face...

Страница 43: ...hase Transit damage and results from alterations are not covered by this warranty IRONHAUS disclaims all other warranties whether expressed or implied and specifically disclaims the implied warranties...

Страница 44: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: