background image

www.ironhaus.com or www.desatech.com

121333-01A

3

State  of  Massachusetts: 

The  installation  must  be 
made by a licensed plumber 
or gas fitter in the Common

-

wealth of Massachusetts.

  WARNING:  This  product 

contains  and/or  generates 

chemicals  known  to  the  State 

of California to cause cancer or 

birth defects or other reproduc

-

tive harm.

IMPORTANT: Read this owner’s 

manual carefully and completely 

before  trying  to  assemble,  op

-

erate  or  service  this  log  set. 

Improper use of this log set can 

cause  serious  injury  or  death 

from  burns,  fire,  explosion, 

electrical  shock  and  carbon 

monoxide poisoning.

 DANGER: Carbon monoxide 

poisoning may lead to death!

This fireplace must be installed by a qualified 
(certified or licensed) service person. It has 

a sealed gas combustion chamber that uses 
a coaxial pipe (pipe within a pipe and having 
the same center) venting system. It brings in 
fresh air for combustion through the outer pipe 
and combustion gases are exhausted through 
the inner pipe. If the glass door assembly and 
venting  pipe  are  not  properly  seated,  con-
nected and sealed, carbon monoxide leakage 
(spillage) can occur.

Carbon Monoxide Poisoning:

 Early signs of 

carbon monoxide poisoning resemble the flu, 

with  headaches,  dizziness  or  nausea.  If  you 

have  these  signs,  the  fireplace  may  not  be 

working properly. 

Get fresh air at once!

 Have 

fireplace serviced. Some people are more af

-

fected by carbon monoxide than others. These 
include pregnant women, people with heart or 

lung disease or anemia, those under the influ

-

ence of alcohol and those at high altitudes.

SAFeTy

Continued

Natural and Propane/LP Gas:

 Natural and 

propane/LP gas are odorless. An odor-making 
agent is added to the gas. The odor helps you 
detect a gas leak. However, the odor added to 
the gas can fade. Gas may be present even 
though no odor exists.
Make  certain  you  read  and  understand  all 
warnings. Keep this manual for reference. It 
is your guide to safe and proper operation of 

this fireplace.

  WARNING:  Any  change  to 

this fireplace or it’s controls can 

be  dangerous.  Do  not  modify 

this fireplace under any circum

-

stances. Any parts removed for 

servicing must be replaced prior 

to operating fireplace.

  WARNING:  Do  not  use  a 

blower  insert,  heat  exchanger 

insert  or  other  accessory  not 

approved for use with this fire

-

place.

  WARNING:  This  appliance 

is only for use with the type of 

gas indicated on the rating plate. 

This appliance is not convertible 

for use with other gases unless 

a certified kit is used.

 WARNING: Do not allow fans 

to blow directly into the fireplace. 

Avoid any drafts that alter burner 

flame patterns.

Due  to  high  temperatures,  the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable  material  on  or  near 

the appliance. Never place any 

objects on the appliance.

Содержание Ironhaus Selway IKC36N Series

Страница 1: ...e Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas suppl...

Страница 2: ...dealer and or shipper immediately if damaged and document with photos etc 2 Remove glass or mesh door s from the frame and set aside in a safe place throughout the construction process 3 Reinstall the...

Страница 3: ...properly Get fresh air at once Have fireplace serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those unde...

Страница 4: ...ly a qualified service person should install service or re pair this fireplace Have fireplace inspected annually by a qualified service person 5 You must keep control compartments burners and circulat...

Страница 5: ...Only the blower requires electricity if in stalled and if you plan to install the blower at a later date do not forget to wire the outlet at the bottom of the fireplace when framing A piezo ignitor an...

Страница 6: ...ese spacers can be placed directly against wall or framing material See framing details on page 7 If you plan on installing a television or enter tainment center recessed above your fire place it is r...

Страница 7: ...cessories for this fireplace see Accessories on page 42 If you are using a separate combustible mantel piece refer to Figure 6 for proper installation height You can install noncombustible mantels at...

Страница 8: ...30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m hori...

Страница 9: ...ust terminate on the out side of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance Adirect vent appliance must have its own venti...

Страница 10: ...le ends of adjacent pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until sections are fully locked see Figure 8 Note Horizontal runs of vent must be s...

Страница 11: ...with wood screws provided see Figure 11 Siding standoff must sit flush against exterior fascia material 7 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before conne...

Страница 12: ...on is required NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cause excessive temperatures which cou...

Страница 13: ...LLATION Recommended Applications Installations requiring a vertical rise on building exterior Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are avail...

Страница 14: ...irements for a horizontal system using two 90 elbows Figure 18 Horizontal Termination Configuration for Venting Using Two 90 Elbows with Termination at 90 with Fireplace 45 Elbow Venting with Two 90 E...

Страница 15: ...g joists If area above ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insulation from falling into required clear ance space If area above ceiling is a liv...

Страница 16: ...igure 22 Vertical Venting Configuration Using One 90 Elbow Vertical Round High Wind Termination Shown 45 Elbow Note Install restrictor into inner collar of fireplace as shown similar factors may cause...

Страница 17: ...been tested and approved for elevations from 0 2000 feet USA and elevations from 0 4500 feet Canada Fireplaces for High Altitude models ending in HA are for installation above 4000 feet only These fi...

Страница 18: ...torm Collar Roof Flashing 0 12 6 12 26 Screws VKC 58 Corner Vent Kit Galvanized Includes 45 Elbow 7 12 Adjustable Pipe Wall Firestop Horizontal Termination 6 Pipe 90 Elbow 18 Screws HHTK 58 High Wind...

Страница 19: ...t directed upward Blower will fit inside back opening and be held in position against back wall by magnets see Figure 26 4 Be certain that all wire terminals are securely attached to terminals on blow...

Страница 20: ...al Note Power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connec tions DO NOT trim excessive length away Enable just enough to make...

Страница 21: ...an Switch Fan Switch N O Green White On 110 115 V A C Blower Motor Black Off 1 2 Black Installing Gas Piping to Fireplace Location WARNING A qualified service person must connect fireplace to gas supp...

Страница 22: ...shown in Figure 32 Locate sediment trap drip leg where it is within reach for cleaning Install in piping sys tem between fuel supply and fireplace Locate sediment trap drip leg where trapped matter is...

Страница 23: ...eplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid...

Страница 24: ...If wires are not connected as shown switch will not work 2 Route 25 ft wire through openings pro vided on sides of burner system to a con venient location to mount your switch 3 Connect one bare wire...

Страница 25: ...removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING If fireplace has been running turn off and un plug fireplace Let cool before removing inner glass doo...

Страница 26: ...1 and 2 1 Pull ember material apart into pieces no larger than a dime Place these pieces loosely and sparingly directly onto ex posed front section of burner see Figure 44 This will create the glowing...

Страница 27: ...in step 6 for left brick panel 11 Replace deflector shield using screws removed in step 7 12 Using screws removed in step 6 replace plenum and attach to burner 13 Carefully replace ember pod and log...

Страница 28: ...mediately call your service technician or gas supplier If pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 9 Turn on all el...

Страница 29: ...rmostatic Mode 1 Press the POWER and LOCK buttons together to turn on the hand held remote control 2 Press AUTO button to select this mode 3 Set the desired room temperature by pressing the TEMP or bu...

Страница 30: ...sachildsafetyfeaturetopreventacciden tal ignition of the fireplace the receiver ON OFF REMOTE switch should be in the OFF position Auto Shutoff Feature 1 If the average room temperature reaches a rang...

Страница 31: ...before each use Have fireplace inspected yearly by a qualified service person Fireplace may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc GLASS Doors...

Страница 32: ...cleaned with compressed air to remove dust dirt or lint Use a vacuum cleaner or small soft bristled brush to remove excess dust dirt or lint Logs If you remove logs for cleaning refer to Installing La...

Страница 33: ...as lines when in stalled 5 Depleted gas supply pro pane LP models only 6 Pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any...

Страница 34: ...l gas company 2 Clean burner see Cleaning and Maintenance page 31 or replace burner orifice 1 Clean burner see Cleaning and Maintenance page 31 or replace burner orifice 2 Replace damaged burner 3 Rep...

Страница 35: ...oval 2 Check vent configuration specifications see Venting Installation page 9 1 This is normal If noise is excessive contact qualified service person 1 Replace 9 volt batteries in receiver and hand h...

Страница 36: ...n 1 Gas leak See Warning statement above 2 Control valve defective 1 Gas leak See Warning statement above OBSERVED PROBLEM Fireplace produces un wanted odors Fireplace shuts off in use Gas odor even w...

Страница 37: ...this product If they can t supply original replacement part s call DESA Heating LLC at 1 866 672 6040 When calling DESA Heating LLC have ready your name your address model and serial numbers of your h...

Страница 38: ...www ironhaus com or www desatech com 121333 01A 38 Parts Models IKc36N Series 6 7 20 17 18 13 2 12 19 8 1 4 11 9 3 5 10 14 21 23 22 15 16...

Страница 39: ...1 02 Bottom Louver Assembly 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 Heat Shield 1 10 116541 01 Burner Assembly NG see page 40 1 116211 05 Burner Assembly fo...

Страница 40: ...www ironhaus com or www desatech com 121333 01A 40 PARTS Burner assembly models IKc36N Series 7 15 10 12 1 12 2 3 13 9 11 21 22 TPTH TP TH 6 12 14 18 17 17 18 19 20 16 14 8 4 5...

Страница 41: ...32 x 3 8 Zinc 2 8 116572 01 Tubing Assembly 1 9 111288 02 Flex Gas Line 1 10 108084 02 Pilot Assembly NG 1 108084 05 Pilot Assembly HA Models 1 11 14389 Natural Gas Valve 1 117370 01 Natural Gas High...

Страница 42: ...ed in this manual Flexible gas Line connector CIK For all models Propane natural gas conversion kit IMPORTANT NOT to be used for High Alti tude HA Models PCDM 36KC Propane LP Gas Conver sion Kit Face...

Страница 43: ...hase Transit damage and results from alterations are not covered by this warranty IRONHAUS disclaims all other warranties whether expressed or implied and specifically disclaims the implied warranties...

Страница 44: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: