background image

www.desatech.com

119421-01E

27

PARTS

This  list  contains  replaceable  parts  used  in  your  heater.  When  ordering  parts,  follow  the 

instructions listed under 

Replacement Parts 

on page 25 of this manual.

KEY 
NO.

PART NO. DESCRIpTIOn

QTY.

1

119420-01 Front Log (#1)

1

2

119420-02 Middle Log (#2)

1

3

119420-03 Back Log (#3)

1

4

119420-06 Right Crossover Log (#4)

1

5

119420-05 Middle Crossover Log (#5)

1

6

119420-04 Left Back Crossover Log (#6)

1

7

102844-02

Lower Bracket

1

8

098867-10 Gas Regulator (LP)

1

098867-14 Gas Regulator (NG)

1

9

102798-01 Inlet Tube

1

10 102779-06 Outlet Burner Tube (LP)

1

102779-03 Outlet Burner Tube (NG)

1

11

099056-19

Burner Orifice Injector (LP)

1

099056-26

Burner Orifice Injector (NG)

1

12 111124-01 Burner Retainer Spring

1

13 102980-01 Burner

1

14 119583-01 Control Valve (LP)

1

102568-07 Control Valve (NG)

1

15 098508-01 Valve Retainer Nut

1

16 098354-01

Control Knob

1

17 102445-01

Piezo Ignitor

1

18 099387-08 Pilot Tube

1

19 098271-10 Ignitor Cable

1

20 PP224

ODS Pilot (LP)

1

PP229

ODS Pilot (NG)

1

21 M11084-38

Hex Screw, #8-18 x 0.38

8

22 098276-01

Hex Head Plug, 1/8 NPT

1

23 098249-01

Nut, M5

2

24

**

Painted Base Assembly

1

PARTS AVAILABLE - NOT SHOWN

100563-01 Warning Plate

1

101055-02 Lighting Instructions Plate

1

100565-01 Warning Plate Fastener 

1

100639-01 Caution Decal

1

101449-04 Control Position Decal

1

101137-02

Hardware Kit

1

GA6060

Lava Rock

1

** Not a field replaceable part.

HDVF3018P HDVF3018N

Содержание HDVF3018N

Страница 1: ...of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any...

Страница 2: ...itisinstalled Provisions for adequate combustion and ventila tion air must be provided RefertoAirforCombustion and Ventilation section on page 5 of this manual This appliance may be in stalled in an a...

Страница 3: ...ntrols can be dangerous WARNING Donotallowfans toblowdirectlyintothefireplace Avoidanydraftsthatalterburner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burne...

Страница 4: ...1 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated thevaporsfromtheseproductsmay create a white powder residue within burner box or on adjacent walls or f...

Страница 5: ...ibit the use of vent free heaters This heater may also be operated as a vented decorative ANSI Z21 60 product by opening the flue damper Safety Pilot This heater has a pilot with an Oxygen Deple tion...

Страница 6: ...ining Fresh Air Flow for Heater Location Confined and Unconfined Space National Fuel Gas Code ANSI Z223 1 NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1 000...

Страница 7: ...l GasCode ANSIZ223 1 NFPA54 theInternationalFuelGasCode or applicable local codes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When...

Страница 8: ...nce is equipped for either natural gas or propane LP gas but not both Gas type is indicated on the rat ingplate Fieldconversionisnot permitted NOTICE Thisheater isintended for use as supplemental heat...

Страница 9: ...rances to combustible materials B Clearances from the top of the fireplace opening to the ceiling should not be less than 42 INSTALLATION Continued Figure 4 Minimum Clearance for Combustible to Wall M...

Страница 10: ...ed Follow minimum clear ances shown in Figure 7 page 11 when using hood NOTICE Surface temperatures of adjacent walls and mantels become hot during operation Walls and mantels above the firebox may be...

Страница 11: ...Clamp Damper Floor Clearances A If installing appliance on the floor level you must maintain the minimum distance of 14 to combustibles see Figure 8 B If combustible materials are less than 14 to the...

Страница 12: ...ot heater will move when you adjust controls Moving heater may cause a gas leak CAUTION Do not pick up heater base assembly by the burner This could damage heater Only handle base as sembly by grates...

Страница 13: ...to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer For propane LP units the installer must supply an external regulator The external regulator...

Страница 14: ...e Pipe Cap Joint Nipple Propane LP From External Regulator 11 W C to 14 W C Pressure Natural From Gas Meter 5 W C to 10 5 W C Pressure controls If sediment trap is not installed or is installed wrong...

Страница 15: ...all joints from equipment shutoff valve to control valve see Figures 16 and 17 Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light hea...

Страница 16: ...ee Figure 20 4 Locate holes on bottom of right crossover log 4 Slide holes onto right pin on middle log 2 and right pin on back log 3 See Figure 21 for placement 5 Locate holes on bottom of middle cro...

Страница 17: ...clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information column 1 If you don t smell gas go to the next step FOR YOUR SAFETY READ BEFORE L...

Страница 18: ...y press and turn control knob coun terclockwise to the PILOT position Press in control knob for five 5 seconds see Figure 22 Note You may be running this heater for the first time after hooking up to...

Страница 19: ...ff Gas to Ap pliance page 18 see Troubleshooting page 21 Note The pilot flame on natural gas units will have a slight curve but flame should be blue and have no yellow or orange color WARNING Turn off...

Страница 20: ...flame comes out of the pilot assembly see Figure 27 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 26 In...

Страница 21: ...talled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep...

Страница 22: ...equipment shut off valve 4 A Contact local propane LP or natural gas com pany B Clean ODS pilot see Cleaning and Maintenance page 19 or replace ODS pilot assembly 5 Hand tighten until snug then tight...

Страница 23: ...ocal propane LP or natural gas company 3 Observeminimuminstallation clearances see page 9 4 Clean burner see Cleaning and Maintenance page 19 or replace burner orifice 1 Turn heater off when us ing fu...

Страница 24: ...tement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement above REMEDY 1 Open window and venti late room Stop using odor causing product...

Страница 25: ...ass For all models Helps deflect heat away from mantel or wall above fireplace Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Parts...

Страница 26: ...www desatech com 119421 01E 26 Parts Variable Manually Controlled MODELS HDVF3018P AND HDVF3018N 24 21 11 12 13 4 6 3 2 21 8 21 7 10 9 16 15 17 19 22 18 14 19 23 20 18 5 1...

Страница 27: ...056 19 Burner Orifice Injector LP 1 099056 26 Burner Orifice Injector NG 1 12 111124 01 Burner Retainer Spring 1 13 102980 01 Burner 1 14 119583 01 Control Valve LP 1 102568 07 Control Valve NG 1 15 0...

Страница 28: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: