www.desatech.com
119921-01F
17
Figure 19 - Disconnecting Jumper Wire
from Control Valve
Jumper
Wire
Control
Valve
INSTALLATION
Continued
Figure 21 - Connecting Wires
Control
Valve
White Wire
From Receiver
Red Wire From
Receiver
11. If logs were removed from heater for in-
stall remote accessory, replace logs (see
Installing Logs
).
Installing Batteries for Remote Receiver
and Hand Held Remote Control
Two 9-volt alkaline batteries (not included)
are required to operate this heater with the
wireless hand-held remote control set. One
battery must be installed in the receiver and
one in the hand-held remote control unit.
Note:
Only use alkaline batteries.
Installing 9-Volt Battery in Receiver
1. Locate back of receiver behind receiver
bracket mounted on base assembly.
2. Locate the battery clip mounted on the
back of the receiver (see Figure 20).
3. Slide a 9-volt battery through the clip.
4. Attach the terminal wires to the battery.
Installing 9-Volt Battery (Not Included) in Hand-
Held Remote Control Unit
1. Remove battery cover on back of remote
control unit.
2. Attach terminal wires to the battery. Place
battery into the battery housing.
3. Replace battery cover onto remote control
unit.
Figure 20 - Installing Remote Receiver
Push
Button
Clips
Bracket
Battery
Clip
9-Volt
Battery
Terminal
Wires
Pad
Figure 22 - Installing Battery in Hand-
Held Remote Control Unit
Battery Cover
9-Volt Battery
Terminal
Wires
Remote Control Unit
Battery
Housing
INSTALLING LOGS
WARNING: Failure to posi
-
tion the parts in accordance
with these diagrams or failure
to use only parts specifically
approved with this heater may
result in property damage or
personal injury.
7. Disconnect jumper wire from control valve at
TPTH and TH locations (see Figure 19).
8. Install remote receiver into receiver
bracket using pads and push button clips
provided with receiver (see Figure 20).
9. Connect wires to control valve at the
TPTH and TH locations as shown in
Figure 21.
Note: Make sure excess wire
does not interfere with burner or pilot.
10. If heater was removed from fireplace be-
fore installation of remote accessory, see
Installing Heater Base Assembly
on page
13 to reinstall heater into fireplace. Test
gas connection for leaks (see
Checking
Gas Connections
, page 15).