background image

www.desatech.com

113900-01D

15

Those Heater Guys

55 E. Stowell Street
Upland, CA 91786
909-98-3011

Tool & Equipment Co.

5 Manila Ave
Hamden, CT 06514-03
1-800-397-7553
03-48-7553

Portable Heater Parts

34 N. County Rd. 400 E.
Valparaiso, IN 46383-9704
All States 
19-46-7441
1-888-619-7060
www.portableheaterparts.com
[email protected]
[email protected]

FBD

1349 Adams St.
Bowling Green, KY 4103-3414
70-846-1199
1-800-654-8534
Fax: 1-800-846-0090
[email protected]

Master Parts Distributor

151 Mound Ave. NW
Grand Rapids , MI 49504-67
616-791-0505
1-800-446-1446
www.nbmc.com

pARTS CENTRALS

These  Parts  Centrals  are  privately-owned  businesses.  They  have  agreed  to  support  our 
customer’s needs by providing original replacement parts and accessories.

Washer Equipment Co.

1715 Main Street
Kansas City, MO 64108-195
KS, MO, AR
816-84-3911
www.washerparts.com

East Coast Energy 

10 East Route 36
W. Long Branch, NJ 07764
73-870-8809
1-800-755-8809
www.njplaza.com/ecep

21st Century

950 Fretz Valley
Perkasie, PA 18944-4034
15-795-0400
1-800-35-488

Laporte’s Parts & Service

444 N. 5th Street
Hartsville, SC 9550-7704
843-33-0191
Parts Department

Cans Unlimited, Inc. 

P.O. Box 645
Taylor, SC 9687-0013
All States 
803-879-3009 
1-800-845-5301

 

[email protected]

Содержание HDFB32C

Страница 1: ...y ANSI Z21 11 2 ap proved gas logs This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This appliance is only for use wi...

Страница 2: ...ith this heater WARNING Donotallowfans to blow directly into the firebox Avoidanydraftsthatalterburner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner pat...

Страница 3: ...o not use the firebox if it has been un der water due to the shock hazard that could result with the blower accessary if installed in place 11 Provide adequate clearances around air openings SAFETY IN...

Страница 4: ...nsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods hel...

Страница 5: ...ome meets all of the three criteria above you must provide additional fresh air See Ventilation Air From Outdoors page 6 If your home does not meet all of the three criteria above proceed to Determini...

Страница 6: ...s water heater ___________ Btu Hr Gas furnace ___________ Btu Hr Vented gas heater ___________ Btu Hr Gas fireplace logs ___________ Btu Hr Other gas appliances _________ Btu Hr Total _ ________ Btu H...

Страница 7: ...ge 12 Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Co...

Страница 8: ...uchorextendbeyond the fireplace screen If your installation does not meet the mini mum clearances in Figure 7 you must raise the mantel to an acceptable height OR remove the mantel Example Figure 6 Mi...

Страница 9: ...front panel pushing the plastic control shaft forward through the opening see Figure 10 INSTALLation Continued 3 While supporting speed control secure control shaft with lock nut by pushing and turnin...

Страница 10: ...pickuplog base assembly by burners This could damage burners Only handle base by grates CAUTION Donotremovethe dataplatesattachedtotheheater base assembly The data plates contain important warranty an...

Страница 11: ...d with mantel As sembly instructions are included with each accessory 2 If using a blower install a properly grounded 120 volt three prong electrical outlet at firebox location if an outlet is not the...

Страница 12: ...ll 39 3 8 27 7 8 55 5 8 34 3 4 Figure 19 Rough Opening for Installing in Corner 34 3 4 17 3 4 33 1 Frame in rough opening Use dimensions shown in Figure 18 for the rough opening If installing in a cor...

Страница 13: ...lappingthefront facing with noncombustible facing material Technical Service You may have further questions about instal lation operation or troubleshooting If so contact DESA Heating Products Technic...

Страница 14: ...ings fluted sides and medallion Accessories Purchase these fireplace accessories from your local dealer If they can not supply these accessories call DESAHeating Products Sales Department at 1 866 672...

Страница 15: ...and Rapids MI 49504 2672 616 791 0505 1 800 446 1446 www nbmc com Parts Centrals These Parts Centrals are privately owned businesses They have agreed to support our customer s needs by providing origi...

Страница 16: ...www desatech com 113900 01D 16 5 14 14 21 13 14 6 1 14 7 14 18 12 12 20 8 16 11 15 17 9 4 2 3 2 14 10 15 19 Illustrated Parts Breakdown HDFB32C...

Страница 17: ...rick Retainer 3 3 114042 01 Rear Firebrick 1 4 114042 02 Side Firebrick 2 5 103207 01 Outer Casing 1 6 Outer Shell Base 1 7 Firebox Wrapper 1 8 103297 01 Assembly Screen 2 9 103773 05 Front Assembly 1...

Страница 18: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 19: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 20: ...inal condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnos...

Отзывы: