112157-01A
8
For more information, visit www.desatech.com
For more information, visit www.desatech.com
INSTALLATION
Thermostat Sensing Bulb (Thermostat Models Only)
Installing Heater To Wall 6,000 and 10,000 Btu/Hr Models (1.8 and 2.9 kW)
INSTALLATION
Continued
THERMOSTAT SENSING BULB
(Thermostat Models Only)
The thermostat sensing bulb has been placed inside the heater for
protection during shipping.
Locating Thermostat Sensing Bulb (for thermostat
applications)
1.
Remove front panel of heater [for 10,000 Btu/Hr (2.9 KW) heater,
see Figure 11 page 9 or for 20,000 Btu/Hr (5.9 KW) heater see
Figure 14, page 10].
2.
Locate thermostat sensing bulb just under burner assembly.
IMPORTANT:
Attach thermostat sensing bulb to back of heater for
proper operation.
Attaching Thermostat Sensing Bulb
1.
Remove thermostat sensing bulb from holders inside heater.
Route through slot opening in bottom of heater.
2.
Place clamp on thermostat sensing bulb as shown in Figure 5.
Clamp is provided in hardware package.
3.
Snap clamp into upper mounting hole as shown in Figure 5.
Mounting hole is located on lower left edge on back of heater.
Make sure the thermostat sensing bulb is pointing up.
Figure 5 - Attaching Thermostat Sensing Bulb
Figure 6 - Mounting Screw Locations
Mounting
Screw
Locations
8
7
/
8
"
(22.5 cm)
Blue Flame
Minimum To
Maintain 6"
Clearance
From Wall
7
3
/
4
"
(19.7 cm)
20
1
/
4
" (51.4 cm)
Minimum To
Maintain 3" (7.6
cm) Clearance
From Floor
FLOOR
JOINING WALL
INSTALLING HEATER TO WALL 6,000 AND
10,000 BTU/HR MODELS (1.8 AND 2.9 KW)
Marking Screw Locations
1.
Determine where you will locate heater.
WARNING: Maintain minimum clearances shown
in Figure 6. If you can, provide greater clearances
from floor and joining wall.
2.
Mark two mounting screw locations on wall (see Figure 6).
Figure 7 - Folding Anchor
Thin Walls (1/4" to 1/2" thick)
(1.6 to 1.2 cm)
Figure 8 - Popping Open Anchor
Wings For Thin Walls
Installing Two Mounting Screws
Note:
Wall anchors and mounting screws are in hardware package.
The hardware package is provided with heater.
Attaching to wall stud method
For attaching mounting screw to wall stud
1.
Drill hole at marked location using 9/64" drill bit.
2.
Insert mounting screw into wall stud.
3.
Tighten screw until 1/16" (1.6 mm) space (thickness of penny)
is between screwhead and wall.
Attaching to wall anchor method
Follow instructions below to attach mounting screws to hollow walls
(wall areas between studs) or solid walls (concrete or masonry).
1.
Drill holes at marked locations using 5/16" drill bit. For solid
walls (concrete or masonry), drill at least 1
1
/
4
" (3.2 cm) deep.
2.
Fold wall anchor (see Figure 7).
3.
Insert wall anchor (wings first) into hole. Tap anchor flush
to wall.
4.
For thin walls [1/2" (1.27 cm) or less], insert red key into wall
anchor. Push red key to “pop” open anchor wings (see Figure 8).
IMPORTANT:
Do not hammer key! For thick walls [over 1/2"
(1.27 cm) thick] or solid walls, do not pop open wings.
Clamp
Thermostat
Sensing Bulb