Desa GA9150A Скачать руководство пользователя страница 9

www.desatech.com

9

901053-01J

O

F

F  

 PIL

OT

   O

N

   

   

   

    

   

Figure 17 - Control Knob and Ignitor 

Button Location (Shown as Supplied, No 

Control Options)

Control 
Knob

Ignitor 
Button

4.  Press in and turn control knob clockwise 

 to the OFF position.

5.  Wait five (5) minutes to clear out any gas. 

Then  smell  for  gas,  including  near  the 
floor. If you smell gas, STOP! Follow “B” 
in the safety information. If you don’t smell 
gas, go to the next step.

6.  Press in and turn control knob counter-

clockwise 

  to  the  PILOT  position. 

Press in control knob for five (5) seconds 
(see Figure 17). 

 

Note:  You  may  be  running  this  log  set 
for the first time after hooking up to gas 
supply. If so, the control knob may need 
to be pressed in for 30 seconds or more. 
This will allow air to bleed from the gas 
system

.

7.  With control knob pressed in, press and 

release ignitor button. This will light pilot. 
If  needed,  keep  pressing  ignitor  button 
until pilot lights.

 

Note: If pilot does not stay lit, contact a 
qualified service person or gas supplier 
for repairs. Until repairs are made, light 
pilot with match. To light pilot with match, 
see Manual Lighting Procedure

8.  Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds, 
release control knob.
• If control knob does not pop out when 

released,  contact  a  qualified  service 
person or gas supplier for repairs.

 

Note:  If  pilot  goes  out,  repeat  steps  4 
through 8

9.  Slightly push in and turn control knob coun-

terclockwise 

 to the ON position.

10. Wait  one  minute  and  switch  selector 

switch to the ON position to light burner.

11. Turn control knob clockwise 

 to the 

PILOT position, or set selector switch in 
the OFF position.

OPERATION

Continued 

Figure 18 - Thermopile and Pilot

Pilot

Thermopile

 

TO TURN OFF GAS 

TO APPLIANCE

Shutting Off Appliance

1.  Turn control knob clockwise 

 to the 

OFF position.

2. 

If  Using  Optional  Hand-Held  Remote: 

Set 

selector  switch  in  the  OFF  position  to 
prevent draining battery. 

3.  Turn off all electrical power to appliance 

if service is to be performed.

MANUAL LIGHTING 

PROCEDURE

1.  Follow steps 1 through 6 under 

Lighting 

Instructions

, starting on page 8.

2.  Depress control knob and light pilot with 

match. 

3.  Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds, 
release  control  knob.  Now  follow  steps 
9  and  10,  under 

Lighting  Instructions

column 1

.

Содержание GA9150A

Страница 1: ...with natural gas orifice 901073 01 Piezo Ignitor Electrode 901072 01 Steel Shroud Pilot Kit 106823 01 Piezo Ignitor Cover 106824 01 Natural Gas Brass Orifice 901064 03 Natural Gas Brass Orifice 90106...

Страница 2: ...d with natural gas If you are unsure of the proper applica tion call dealer where you bought log set If the fireplace does not have a gas supply shutoff valve one must be installed CONNECTING TO GAS S...

Страница 3: ...er or greater to allow proper gas volume to log set If pipe is too small undue loss of volume will occur INSTALLATION Continued Installation must include an equipment shutoff valve union and plugged 1...

Страница 4: ...nts of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect log set and equipment shutoff valve to gas su...

Страница 5: ...e 6 Replace with the proper orifice for your log set See technical information charts in Figure 1 on page 2 3 Thread the gas control valve onto the burner inlet fitting see Figure 7 Use thread sealant...

Страница 6: ...conversion Figure 12 Remove Burner Inlet Fitting Burner Inlet Fitting for Natural Gas Propane LP Gas Conversion To convert to propane LP gas the regulator pres sure must be reset also the burner inle...

Страница 7: ...Pressure Regulator Tower Diaphragm Spring Components Figure 14 Installing Pressure Regulator Assembly O F F P I L O T O N Mounting Screws Rubber Gasket Identification Label Figure 15 Installing Propan...

Страница 8: ...has a pilot which must be lighted by hand When lighting the pi lot follow these instructions exactly B BEFORE LIGHTING smell all around the ap pliance area for gas Be sure to smell next to the floor b...

Страница 9: ...light pilot with match see Manual Lighting Procedure 8 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob If control knob does not pop out when rel...

Страница 10: ...r on and off with the hand held remote control unit IMPORTANT Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit This will drain the battery On Off Series Model HR...

Страница 11: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 12: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...