Desa GA9150A Скачать руководство пользователя страница 4

www.desatech.com

901053-01J

4

INSTALLATION

Continued 

Figure 4 - Equipment Shutoff Valve

Open

Closed

Equipment 
Shutoff Valve

CHECKING GAS CONNECTIONS

 WARNING: Test all gas piping 

and  connections,  internal  and 

external to unit, for leaks after 

installing or servicing. Correct 

all leaks at once.

  WARNING:  Never  use  an 

open flame to check for a leak. 

Apply a noncorrosive leak detec-

tion fluid to all joints. Bubbles 

forming show a leak. Correct all 

leaks at once.

 CAUTION: If using propane/

LP  gas,  make  sure  external 

regulator  has  been  installed 

between propane/LP supply and 

appliance.

PRESSURE TESTING GAS SUPPLY 
PIPING SYSTEM 
Test Pressures In Excess Of 1/2 PSIG 
(3.5 kPa)

1.  Disconnect  log  set  and  its  individual 

equipment shutoff valve from gas supply 
piping system.

2.  Cap off open end of gas pipe where equip-

ment shutoff valve was connected.

3.  Pressurize supply piping system by either 

opening  propane/LP  supply  tank  valve 
for propane/LP gas or opening main gas 
valve  located  on  or  near  gas  meter  for 
natural gas, or using compressed air.

4.  Check all joints of gas supply piping sys-

tem. Apply  noncorrosive  leak  detection 
fluid to all joints. Bubbles forming show a 
leak.

5.  Correct all leaks at once.
6.  Reconnect log set and equipment shutoff 

valve to gas supply. Check reconnected 
fittings for leaks.

Test Pressures Equal To or Less Than 
1/2 PSIG (3.5 kPa)

1.  Close  equipment  shutoff  valve  (see 

Figure 4).

2.  Pressurize supply piping system by either 

opening  propane/LP  supply  tank  valve 
for propane/LP gas or opening main gas 
valve  located  on  or  near  gas  meter  for 
natural gas, or using compressed air.

3.  Check all joints from gas meter for natural 

gas (see Figure 5, page 5) or propane/LP 
supply (see Figure 6, page 5) to equip-
ment  shutoff  valve. Apply  noncorrosive 
leak detection fluid to all joints. Bubbles 
forming show a leak.

4.  Correct all leaks at once.

Tee  Pipe  Cap
Joint  Nipple

Approved Flexible 
Gas Hose (if allowed 
by local codes)

Figure 3 - Gas Connection

* Purchase the optional CSA design-certified 
equipment shutoff valve from your dealer.
** Minimum inlet pressure for purpose of input 
adjustment.   

3" Minimum

Sediment Trap

CSA Design-Certified 
Equipment Shutoff Valve 
With 1/8" NPT Tap*

Natural Gas

From Gas Meter 
(5" W.C.** to 10.5" 
W.C. Pressure)

      Propane/LP

 

          From External
                Regulator 
                (11" W.C.**    
                to 14" W.C. 
                Pressure)

Содержание GA9150A

Страница 1: ...with natural gas orifice 901073 01 Piezo Ignitor Electrode 901072 01 Steel Shroud Pilot Kit 106823 01 Piezo Ignitor Cover 106824 01 Natural Gas Brass Orifice 901064 03 Natural Gas Brass Orifice 90106...

Страница 2: ...d with natural gas If you are unsure of the proper applica tion call dealer where you bought log set If the fireplace does not have a gas supply shutoff valve one must be installed CONNECTING TO GAS S...

Страница 3: ...er or greater to allow proper gas volume to log set If pipe is too small undue loss of volume will occur INSTALLATION Continued Installation must include an equipment shutoff valve union and plugged 1...

Страница 4: ...nts of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect log set and equipment shutoff valve to gas su...

Страница 5: ...e 6 Replace with the proper orifice for your log set See technical information charts in Figure 1 on page 2 3 Thread the gas control valve onto the burner inlet fitting see Figure 7 Use thread sealant...

Страница 6: ...conversion Figure 12 Remove Burner Inlet Fitting Burner Inlet Fitting for Natural Gas Propane LP Gas Conversion To convert to propane LP gas the regulator pres sure must be reset also the burner inle...

Страница 7: ...Pressure Regulator Tower Diaphragm Spring Components Figure 14 Installing Pressure Regulator Assembly O F F P I L O T O N Mounting Screws Rubber Gasket Identification Label Figure 15 Installing Propan...

Страница 8: ...has a pilot which must be lighted by hand When lighting the pi lot follow these instructions exactly B BEFORE LIGHTING smell all around the ap pliance area for gas Be sure to smell next to the floor b...

Страница 9: ...light pilot with match see Manual Lighting Procedure 8 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob If control knob does not pop out when rel...

Страница 10: ...r on and off with the hand held remote control unit IMPORTANT Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit This will drain the battery On Off Series Model HR...

Страница 11: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 12: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: