Desa GA9150A Скачать руководство пользователя страница 2

www.desatech.com

901053-01J

2

INSTALLATION

 

 

 

Btu/Hr Input  Btu/Hr Input 

Minimum

 

MODEL 

DESCRIPTION 

Natural Gas  Propane Gas  Vent Opening

 

CVSR18 

18" Single Burner 

50,000 

40,000 

8" dia.

 

CPVSR18 

18" Single Burner 

50,000 

40,000 

8" dia.

 

CVSR24 

24" Single Burner 

60,000 

50,000 

8" dia.

 

CPVSR24 

24" Single Burner 

60,000 

50,000 

8" dia.

 

CVDR18 

18" Dual Burner 

55,000 

45,000 

8" dia.

 

MD18 

18" Dual Burner 

55,000 

45,000 

8" dia.

 

CVDR24 

24" Dual Burner 

65,000 

55,000 

8" dia.

 

MD24 

24" Dual Burner 

65,000 

55,000 

8" dia.

 

CVDR30 

30" Dual Burner 

70,000 

60,000 

8" dia.

 

(C)BFL(T,R)  18" Triple Burner 

65,000 

55,000 

8" dia.

 

(C)BFL(T,R)  24" Triple Burner 

70,000 

60,000 

8" dia.

 

FUEL PRESSURE 

 

 

SPECIFICATIONS (W.C.) 

 

 

Inlet 

Manifold* 

 

NG  5.5"-10.5" 

3.5" 

 

LP 

11"-13" 

10"

 

* ± .2"

CHECK GAS TYPE

You  must  install  this  Remote  Ready  Valve/
Pilot Kit if your gas type is propane/LP. For ad-
ditional convenience and safety, this  Remote 
Ready Valve/Pilot Kit can be used with natural 
gas. If you are unsure of the proper applica-
tion, call dealer where you bought log set.
If the fireplace does not have a gas supply 
shutoff valve, one must be installed.

CONNECTING TO GAS SUPPLY

  WARNING:  This  appliance 

requires  a  1/2"  NPT  (National 

Pipe Thread) inlet connection to 

the pressure regulator.

Figure 1 - Technical Information Charts

MINIMUM FIREBOX SIZES

  

FRONT 

BACK

 MODEL 

WIDTH*  WIDTH**  DEPTH  HEIGHT

 18DR/SR/MD 

28" 

16" 

14" 

18"

 24DR/SR/MD  29 

3

/

4

17" 

15 

1

/

2

18"

 30DR 

36" 

27" 

18" 

18"

 BFL18 

28" 

16" 

15 

1

/

2

18"

 BFL24 

30" 

22" 

15 

1

/

2

18"

*  Add 6" if valve/pilot is used
**At depth indicated

BURNER ORIFICE

 

 

NATURAL 

PROPANE/LP

 

LOG SIZE 

In.  Num.  CLR.  In.  Num.  CLR.

  18SR/DR/MD 

0.129  30  Green  0.073  49 

Red

  24SR/DR/MD/BFL18 0.141  28  Yellow  0.086  44  Orange
  30DR/BFL24 

0.157  22  Yellow/ 0.089  43 

Black

   

 

 

Blue

 WARNING: A qualified service 

person must connect log set to gas 

supply. Follow all local codes.

 CAUTION: Never connect pro-

pane/LP appliance directly to the 

propane/LP supply. This appliance 

requires  an  external  regulator 

(not supplied). Install the external 

regulator between the heater and 

propane/LP supply.

Содержание GA9150A

Страница 1: ...with natural gas orifice 901073 01 Piezo Ignitor Electrode 901072 01 Steel Shroud Pilot Kit 106823 01 Piezo Ignitor Cover 106824 01 Natural Gas Brass Orifice 901064 03 Natural Gas Brass Orifice 90106...

Страница 2: ...d with natural gas If you are unsure of the proper applica tion call dealer where you bought log set If the fireplace does not have a gas supply shutoff valve one must be installed CONNECTING TO GAS S...

Страница 3: ...er or greater to allow proper gas volume to log set If pipe is too small undue loss of volume will occur INSTALLATION Continued Installation must include an equipment shutoff valve union and plugged 1...

Страница 4: ...nts of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect log set and equipment shutoff valve to gas su...

Страница 5: ...e 6 Replace with the proper orifice for your log set See technical information charts in Figure 1 on page 2 3 Thread the gas control valve onto the burner inlet fitting see Figure 7 Use thread sealant...

Страница 6: ...conversion Figure 12 Remove Burner Inlet Fitting Burner Inlet Fitting for Natural Gas Propane LP Gas Conversion To convert to propane LP gas the regulator pres sure must be reset also the burner inle...

Страница 7: ...Pressure Regulator Tower Diaphragm Spring Components Figure 14 Installing Pressure Regulator Assembly O F F P I L O T O N Mounting Screws Rubber Gasket Identification Label Figure 15 Installing Propan...

Страница 8: ...has a pilot which must be lighted by hand When lighting the pi lot follow these instructions exactly B BEFORE LIGHTING smell all around the ap pliance area for gas Be sure to smell next to the floor b...

Страница 9: ...light pilot with match see Manual Lighting Procedure 8 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob If control knob does not pop out when rel...

Страница 10: ...r on and off with the hand held remote control unit IMPORTANT Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit This will drain the battery On Off Series Model HR...

Страница 11: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 12: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...