Figure 15 - Installing Propane/LP Pilot Orifice
Pilot Injector
Changing Pilot Orifice
The pilot is provided with a natural gas orifice installed. For
propane/LP gas you must remove it and replace it with an propane/
LP orifice. The hardware kit contains an propane/LP orifice with a
red stripe for converting the pilot.
1.
Gently loosen and remove the pilot line connection from the
bracket (see Figure 15).
2.
Replace the injector (see Figure 15) with the propane/LP pilot
injector with the red stripe.
3.
Replace and tighten the pilot line to the bracket.
4.
Continue with step 3 under Natural Gas Installation, pages 7
and 8.
INSTALLATION
Continued
Figure 12 - Installing Cover, Control Knob, and Piezo Ignitor
Propane/LP Gas Conversion
To convert to propane/LP gas, the burner inlet fitting and pilot
orifice must be replaced. The propane/LP burner inlet fitting is
supplied with the orifice installed for a 24" log set. If you have an
18" or 30" set, you must change this orifice also. See Figure 1, page
3 for product identification.
Burner Inlet Fitting
1.
Remove the burner inlet fitting from the burner pan assembly.
DO NOT remove the orifice from this fitting. The propane/LP
burner inlet fitting is included in the hardware kit (see Figure 13).
2.
Be sure to use the correct orifice for your appliance. The hard-
ware kit included with this appliance contains two orifices with
a cone-like shape. If you have an 18" set, the orifice for the
burner inlet fitting is red; for a 30" set, it is black. If you have
a 24" log set, the orifice is already installed inside the fitting.
3.
For an 18" or 30" set, use a 10mm socket or nut driver to re-
move the orifice from the propane/LP burner inlet fitting.
Choose the correct orifice for your log set size and install in
place of the orifice you just removed.
Figure 13 - Burner Inlet Fittings with Injectors
Figure 14 - Remove Burner Inlet Fitting
Burner Inlet
Fitting for
Natural Gas
4.
Using thread sealant (resistant to the action of propane/LP gas)
on larger end of fitting, screw the burner inlet fitting through
hole and into burner manifold. Tighten using a wrench.
5 . Follow steps 1 through 12 under Natural Gas Installation, pages
7 and 8.
10. Install thermocouple, pilot, and ignitor onto valve cover as
shown in Figure 12. Use the provided screws.
11. Push the control rod extension onto the “D” shaped control
rod through the center hole in the cover.
12. Install the position decal and control knob making sure to align
the marks with the correct stop positions of the gas control.
Pilot position will allow the knob to push in about 1/2". Align
the decals in the pilot position.
Piezo Ignitor
Control Rod
Extension
Screw
Valve Cover
Control
Knob
Thermocouple
Ignitor
Pilot
NATURAL
GAS FITTING
PROPANE/LP
GAS FITTING
Injector for
Natural Gas
Injector for
Propane/LP Gas
INSTALLATION
Optional GA9050A ON/OFF Safety Valve/Pilot Kit Assembly (Cont.)