VENTING INSTALLATION
Continued
FLASHING INSTALLATION (V6F-10DM
OR V12F-10DM)
'HWHUPLQHÀDVKLQJWREHXVHGZLWKURRIRSHQ
-
LQJFKDUW6OLGHÀDVKLQJRYHUSLSHXQWLOEDVHLV
ÀDWDJDLQVWURRI5HSODFHDVPDQ\VKLQJOHVDV
QHHGHGWRFRYHUH[SRVHGDUHDDQGÀDVKLQJ
base. Secure in position by nailing through
shingles (see Figure 13). DO NOT NAIL
THROUGH FLASHING CONE.
Nail Only
Outer
Perimeter
of Flashing
Storm
Collar
Flashing
Cone
Underlap Shingles
at Bottom
Overlap
Shingles Top
and Sides Only
Figure 13 - Flashing Installation
Installing Flashing on a Metal Roof
:KHQ LQVWDOOLQJ ÀDVKLQJ RQ D PHWDO URRI LW
is required that putty tape be used between
ÀDVKLQJDQGURRI)ODVKLQJPXVWEHVHFXUHG
to roof using #8 x 3/4" screws and then sealed
with roof coating to prevent leakage through
screw holes. A roof coating must also be
DSSOLHG DURXQG WKH SHULPHWHU RI ÀDVKLQJ WR
provide a proper seal.
Storm Collar Installation (SC2-1)
Place storm collar over pipe and slide down
XQWLO LW LV VQXJ DJDLQVW RSHQ HGJH RI ÀDVK
-
ing (see Figure 14). Apply waterproof caulk
around perimeter of collar to provide a proper
seal.
Figure 14 - Storm Collar
Chimney
Pipe
Waterproof
Caulk
Storm
Collar
Flashing
Terminations/Spark Arrestor
7KH¿UHSODFHV\VWHPPXVWEHWHUPLQDWHGZLWK
the listed round top or chase terminations.
In any case, refer to installation instructions
supplied with termination.
CAUTION: Do not seal open-
LQJVRQWKHURRIWRSÀDVKLQJ)RO
-
low the installation instructions
provided with the termination
being used.
Secure
Termination
to Outer
Pipe with 3
Screws
RLT-12D
(Shown)
Level of
Flue Gas
Outlet
Stainless
Inner Flue
Pipe
Waterproof
Caulking
Storm
Collar
Flashing
Underlap
Shingles
Figure 15 - Termination
Overlap
Shingles (Top
and Sides of
Flashing Base)
CHASE INSTALLATIONS
Instructions for chase installations are includ-
ed with the chase style termination chosen.
In a multiple chase installation, be sure to
provide adequate distance between termi-
nations to prevent smoke spillage from one
termination to another. Terminations must be
separated a minimum of 24" center to center
and stacked at a minimum vertical height dif-
ference of 18" (see Figure 16, page 10).
Note: If a decorative shroud is to be installed,
FRQWDFWWKHPDQXIDFWXUHUIRUVSHFL¿FDWLRQV