SAFETy

Continued

1.  This appliance is only for use with the type 

of gas indicated on the rating plate. This 

appliance is not convertible for use with 

other gases.

2.  Do not place propane/LP supply tank(s) 

inside any structure. Locate propane/LP 
supply tank(s) outdoors (propane/LP units 
only).

3.  If you smell gas

• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not 

use any phone in your building

• immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup

-

plier’s instructions

• if  you  cannot  reach  your  gas  supplier, 

call the fire department

4.  This heater shall not be installed in a bed-

room or bathroom, unless installed as a 

vented appliance. See 

Installing Damper 

Clamp Accessory for Vented Operation

page 12.

5.  Before installing in a solid fuel burning fire

-

place, the chimney flue and firebox must 
be cleaned of soot, creosote, ashes and 
loose paint by a qualified chimney cleaner. 
Creosote will ignite if highly heated. A dirty 
chimney  flue  may  create  and  distribute 
soot  within  the  house.  Inspect  chimney 
flue for damage. If damaged, repair flue 
and firebox before operating heater.

6.  Do  not  burn  solid-fuel  in  a  masonry  or 

UL127  factory-built  fireplace  in  which  a 

vent-free room heater is installed.

7.  If fireplace has glass doors, never operate 

this heater with glass doors closed. If you 
operate  heater  with  doors  closed,  heat 
buildup inside fireplace will cause glass to 

burst. Make sure there are no obstructions 

across openings of fireplace.

8.  To prevent the creation of soot, follow the 

instructions in 

Cleaning

, page 20.

9.  Before using furniture polish, wax, carpet 

cleaner or similar products, turn heater off. If 
heated, the vapors from these products may 
create a white powder residue within burner 
box or on adjacent walls and furniture.

10. This heater needs fresh, outside air ven

-

tilation to run properly. This heater has an 
Oxygen Depletion Sensing (ODS) safety 

shutoff system. The ODS shuts down the 

heater if enough fresh air is not available. 
See 

Air for Combustion and Ventilation

page 6. If heater keeps shutting off, see 

Troubleshooting

, page 22.

11. Do not run heater

• where flammable liquids or vapors are 

used or stored

• under dusty conditions

12. Do not use this heater to cook food or burn 

paper or other objects.

13. Do not use heater if any part has been ex-

posed to or under water. Immediately call 
a qualified service technician to inspect 

the room heater and to replace any part 
of the control system and any gas control 

which has been under water.

14. Do not operate heater if any log is broken. 

Do not operate heater if a log is chipped 

(dime-sized or larger).

15. Turn heater off and let cool before servic-

ing, installing or repairing. Only a qualified 
service person should install, service or 

repair heater.

16. Operating  heater  above  elevations  of 

4,500 feet may cause pilot outage.

17. To  prevent  performance  problems,  do 

not use propane/LP fuel tank of less than 
100 lb. capacity (propane/LP units only).

18. Provide adequate clearances around air 

openings.

Содержание EZ18N

Страница 1: ...l switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department...

Страница 2: ...ING This is an unvented gas fired heat er It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion...

Страница 3: ...though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any change to this heater...

Страница 4: ...p inside fireplace will cause glass to burst Make sure there are no obstructions across openings of fireplace 8 To prevent the creation of soot follow the instructions in Cleaning page 20 9 Before usi...

Страница 5: ...must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy...

Страница 6: ...rectly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the un confined space Adjoining rooms are communicating only if there are...

Страница 7: ...unt of Btu Hr used ________ Btu Hr maximum the space can support ________ Btu Hr actual amount used Example 51 200 Btu Hr maximum the space can support 73 000 Btu Hr actual amount of Btu Hr used The s...

Страница 8: ...ted Crawl Space To Crawl Space To Attic Installation Figure 2 Ventilation Air from Inside Building Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 Ventilati...

Страница 9: ...pe of gas natural or propane LP If your gas supply is not the correct gas type do not install heater Call dealer where you bought heater for proper type heater WARNING This appliance is for either nat...

Страница 10: ...e material is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See Figure 5 and Figures 6 and 7 page 11 for minimum clearances IMPORTANT If you cannot meet thes...

Страница 11: ...lled at Floor Level Figure 7 Minimum Mantel Clearances When Using Hood Floor Clearances A If installing appliance on the floor level you must maintain the minimum distance of 14 to combustibles see Fi...

Страница 12: ...inimum permanent flue opening you must provide Attach damper clamp so the minimum permanent flue open ing will be maintained at all times Area of Various Standard Round Flues Diameter Area 5 20 sq inc...

Страница 13: ...e to Fireplace Floor Masonry Screw CONNECTING TO GAS SUPPLY WARNING This appliance requires a 1 2 NPT National Pipe Thread inlet connection to the pressure regulator WARNING A qualified service person...

Страница 14: ...nt lightly to male NPT threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves Propane LP Supply Tank External Regulator with Vent Po...

Страница 15: ...r near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all...

Страница 16: ...ailure to use only parts specifically approved with this heater may result in property damage or personal injury It is very important to install these logs exactly as instructed Do not modify logs Onl...

Страница 17: ...uctions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SME...

Страница 18: ...ou don t smell gas go to the next step Operation Continued Figure 23 Pilot Ignitor Electrode Thermocouple Pilot Burner Figure 22 Control Knob and Ignitor Button Location OFF PILOT ON Control Knob Elec...

Страница 19: ...kwise to the PILOT position 3 Press in control knob and turn clockwise to the OFF position 4 Close equipment shutoff valve see Figure 15 page 15 Manual lighting procedure 1 Follow steps 1 through 5 un...

Страница 20: ...rculating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need more frequent cleaning due to excessi...

Страница 21: ...slotted burner flame holes should be open with yellow flame pres ent All round burner flame holes should be open with a small blue flame present Some burner flame holes may become blocked by debris or...

Страница 22: ...hile in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free i...

Страница 23: ...te for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning page 20 or re...

Страница 24: ...checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 11 4 Clean burners see Clean ing page 20 or replace burner orifice s 1 Turn heater off...

Страница 25: ...s from paint hair spray glues cleaners chemicals new carpet etc See IMPOR TANT statement above 2 Low fuel supply propane LP only 3 Gas leak See Warning statement at top of page 1 Gas leak See Warning...

Страница 26: ...www desatech com 119678 01C 26 Parts Models EZ18N EZ18P EZ24N and EZ24P LPG 11 13 31 10 30 4 1 8 3 12 8 2 5 6 7 28 22 23 8 20 17 24 26 19 21 15 2 23 29 9 18 16 25 8 8...

Страница 27: ...ural 1 12 101004 04 Front Burner Injector Natural 1 101004 01 Front Burner Injector Propane LP 1 101004 22 Front Burner Injector Natural 1 101004 06 Front Burner Injector Propane LP 1 13 107634 01 NG...

Страница 28: ...2 3 5 6 7 KEY NO PART NO DESCRIPTION QTY 1 114984 01 Middle Log 1 114984 12 Middle Log 1 2 114984 02 Left Top Log 1 114984 13 Left Top Log 1 3 114984 03 Right Top Log 1 114984 14 Right Top Log 1 4 114...

Страница 29: ...acement part s call DESA Heating LLC at 1 866 672 6040 for referral information A list of authorized dealers can be found by visiting www desatech com When calling DESA Heating LLC have ready model an...

Страница 30: ...it gives you the tools and instructions to make it easy to clean all critical areas of your appliance Accessories FIREPLACE HOOD Black GA6050 Brass GA6052 Antique Brass GA6053 For all models Helps def...

Страница 31: ..._____________________________ __________________________________________________________ __________________________________________________________ ____________________________________________________...

Страница 32: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: