background image

www.desatech.com

119678-01C

13

INSTALLATION

Continued

Installation Items Needed

•  hardware package (provided with heater)
•  approved flexible gas hose and fittings (not 

provided) (if allowed by local codes)

•  sealant (resistant to propane/LP gas, not 

provided)

•  electric drill with 3/16" masonry drill bit

1.  Apply  pipe  joint  sealant  lightly  to  male 

threads  of  gas  fitting  (not  provided). 

Connect  approved  flexible  gas  hose  to 

regulator of heater (see Figure 11). 

2. 

Position heater base assembly in fireplace. 

3.  Mark  screw  locations  through  holes  in 

front  panel  of  base  (see  Figure  12).  If 

installing in a brick bottom fireplace, mark 
screw locations in mortar joint of bricks.

4.  Remove heater base from fireplace.
5.  Drill holes at marked locations using 3/16" 

drill bit.

6.  Attach base, through holes in front panel 

of base, to fireplace floor using masonry 
screws  provided  in  hardware  package 

(see Figure 12).

7.  Connect to gas supply. See 

Connecting 

To Gas Supply

.

Figure 11 - Attaching Flexible Gas Hose 

to Heater Gas Regulator 

Figure 12 - Attaching Base to Fireplace 

Floor

Masonry Screw

CONNECTING TO GAS SUPPLY

  WARNING:  This  appliance 

requires  a  1/2"  NPT  (National 

Pipe Thread) inlet connection to 

the pressure regulator.

  WARNING:  A  qualified 

service  person  must  connect 

heater to gas supply. Follow all 

local codes.

  CAUTION:  Never  connect 

propane/LP  fireplace  directly 

to the propane/LP supply. This 

heater requires an external regu

-

lator  (not  supplied).  Install  the 

external regulator between the 

heater and propane/LP supply.

 WARNING: Never connect 

natural gas fireplace to private 

(non-utility)  gas  wells.  This 

gas  is  commonly  known  as 

wellhead gas.

Installation Items Needed

Before installing heater, make sure you have 
the items listed below.
•  external regulator (supplied by installer)
•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  test gauge connection *
•  sediment trap
•  tee joint
•  pipe wrench
•  approved  flexible  gas  line  with  gas  con

-

nector  (if  allowed  by  local  codes)  (not 

provided) 

* A  CSA  design-certified  equipment  shutoff 
valve with 1/8" NPT tap is an acceptable al

-

ternative to test gauge connection. Purchase 

the optional CSA design-certified equipment 

shutoff valve from your dealer.

Heater Gas Regulator

Flexible Gas Hose 

(if allowed by local 

codes)

Содержание EZ18N

Страница 1: ...l switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department...

Страница 2: ...ING This is an unvented gas fired heat er It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion...

Страница 3: ...though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any change to this heater...

Страница 4: ...p inside fireplace will cause glass to burst Make sure there are no obstructions across openings of fireplace 8 To prevent the creation of soot follow the instructions in Cleaning page 20 9 Before usi...

Страница 5: ...must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy...

Страница 6: ...rectly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the un confined space Adjoining rooms are communicating only if there are...

Страница 7: ...unt of Btu Hr used ________ Btu Hr maximum the space can support ________ Btu Hr actual amount used Example 51 200 Btu Hr maximum the space can support 73 000 Btu Hr actual amount of Btu Hr used The s...

Страница 8: ...ted Crawl Space To Crawl Space To Attic Installation Figure 2 Ventilation Air from Inside Building Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 Ventilati...

Страница 9: ...pe of gas natural or propane LP If your gas supply is not the correct gas type do not install heater Call dealer where you bought heater for proper type heater WARNING This appliance is for either nat...

Страница 10: ...e material is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See Figure 5 and Figures 6 and 7 page 11 for minimum clearances IMPORTANT If you cannot meet thes...

Страница 11: ...lled at Floor Level Figure 7 Minimum Mantel Clearances When Using Hood Floor Clearances A If installing appliance on the floor level you must maintain the minimum distance of 14 to combustibles see Fi...

Страница 12: ...inimum permanent flue opening you must provide Attach damper clamp so the minimum permanent flue open ing will be maintained at all times Area of Various Standard Round Flues Diameter Area 5 20 sq inc...

Страница 13: ...e to Fireplace Floor Masonry Screw CONNECTING TO GAS SUPPLY WARNING This appliance requires a 1 2 NPT National Pipe Thread inlet connection to the pressure regulator WARNING A qualified service person...

Страница 14: ...nt lightly to male NPT threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves Propane LP Supply Tank External Regulator with Vent Po...

Страница 15: ...r near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all...

Страница 16: ...ailure to use only parts specifically approved with this heater may result in property damage or personal injury It is very important to install these logs exactly as instructed Do not modify logs Onl...

Страница 17: ...uctions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SME...

Страница 18: ...ou don t smell gas go to the next step Operation Continued Figure 23 Pilot Ignitor Electrode Thermocouple Pilot Burner Figure 22 Control Knob and Ignitor Button Location OFF PILOT ON Control Knob Elec...

Страница 19: ...kwise to the PILOT position 3 Press in control knob and turn clockwise to the OFF position 4 Close equipment shutoff valve see Figure 15 page 15 Manual lighting procedure 1 Follow steps 1 through 5 un...

Страница 20: ...rculating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need more frequent cleaning due to excessi...

Страница 21: ...slotted burner flame holes should be open with yellow flame pres ent All round burner flame holes should be open with a small blue flame present Some burner flame holes may become blocked by debris or...

Страница 22: ...hile in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free i...

Страница 23: ...te for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning page 20 or re...

Страница 24: ...checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 11 4 Clean burners see Clean ing page 20 or replace burner orifice s 1 Turn heater off...

Страница 25: ...s from paint hair spray glues cleaners chemicals new carpet etc See IMPOR TANT statement above 2 Low fuel supply propane LP only 3 Gas leak See Warning statement at top of page 1 Gas leak See Warning...

Страница 26: ...www desatech com 119678 01C 26 Parts Models EZ18N EZ18P EZ24N and EZ24P LPG 11 13 31 10 30 4 1 8 3 12 8 2 5 6 7 28 22 23 8 20 17 24 26 19 21 15 2 23 29 9 18 16 25 8 8...

Страница 27: ...ural 1 12 101004 04 Front Burner Injector Natural 1 101004 01 Front Burner Injector Propane LP 1 101004 22 Front Burner Injector Natural 1 101004 06 Front Burner Injector Propane LP 1 13 107634 01 NG...

Страница 28: ...2 3 5 6 7 KEY NO PART NO DESCRIPTION QTY 1 114984 01 Middle Log 1 114984 12 Middle Log 1 2 114984 02 Left Top Log 1 114984 13 Left Top Log 1 3 114984 03 Right Top Log 1 114984 14 Right Top Log 1 4 114...

Страница 29: ...acement part s call DESA Heating LLC at 1 866 672 6040 for referral information A list of authorized dealers can be found by visiting www desatech com When calling DESA Heating LLC have ready model an...

Страница 30: ...it gives you the tools and instructions to make it easy to clean all critical areas of your appliance Accessories FIREPLACE HOOD Black GA6050 Brass GA6052 Antique Brass GA6053 For all models Helps def...

Страница 31: ..._____________________________ __________________________________________________________ __________________________________________________________ ____________________________________________________...

Страница 32: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: