background image

www.desatech.com

120044-01D

4

SAFETy

Continued

9.  Before using furniture polish, wax, carpet 

cleaner or similar products, turn heater off. If 
heated, the vapors from these products may 

create a white powder residue within burner 
box or on adjacent walls and furniture.

10. This heater needs fresh, outside air ven

-

tilation to run properly. This heater has an 
Oxygen Depletion Sensing (ODS) safety 
shutoff system. The ODS shuts down the 
heater if enough fresh air is not available. 
See 

Air for Combustion and Ventilation

page 6. If heater keeps shutting off, see 

Troubleshooting

, page 24.

11. Do not run heater

• where flammable liquids or vapors are 

used or stored

• under dusty conditions

12. Do not use this heater to cook food or burn 

paper or other objects.

13. Do not use heater if any part has been ex-

posed to or under water. Immediately call 

a qualified service technician to inspect 

the room heater and to replace any part 
of the control system and any gas control 
which has been under water.

14. Do not operate heater if any log is broken. 

Do not operate heater if a log is chipped 

(dime-sized or larger).

15. Turn heater off and let cool before servic-

ing, installing or repairing. Make sure the 

selector switch is in the OFF position. Only 

a qualified service person should install, 

service or repair heater.

16. Make  sure  the  selector  switch  is  in  the 

OFF  position  when  you  are  away  from 
home for long periods of time.

17. Remote-ready heaters must not be con-

nected to any external electrical source.

18. Operating  heater  above  elevations  of 

4,500 feet may cause pilot outage.

19. To prevent performance problems, do not 

use propane/LP fuel tank of less than 100 
lb. capacity (propane/LP units only).

20. Provide adequate clearances around air 

openings.

1.  This appliance is only for use with the type 

of gas indicated on the rating plate. This 
appliance is not convertible for use with 
other gases.

2.  Do not place propane/LP supply tank(s) 

inside any structure. Locate propane/LP 
supply tank(s) outdoors (propane/LP units 
only).

3.  If you smell gas

• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not 

use any phone in your building

• immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup-
plier’s instructions

• if  you  cannot  reach  your  gas  supplier, 

call the fire department

4.  This heater shall not be installed in a bed-

room or bathroom, unless installed as a 

vented appliance. See 

Installing Damper 

Clamp Accessory for Vented Operation

page 12.

5.  Before installing in a solid fuel burning fire

-

place, the chimney flue and firebox must 
be cleaned of soot, creosote, ashes and 
loose paint by a qualified chimney cleaner. 

Creosote will ignite if highly heated. A dirty 

chimney  flue  may  create  and  distribute 

soot  within  the  house.  Inspect  chimney 

flue for damage. If damaged, repair flue 
and firebox before operating heater.

6.  Do  not  burn  solid-fuel  in  a  masonry  or 

UL127  factory-built  fireplace  in  which  a 

vent-free room heater is installed.

7.  If fireplace has glass doors, never operate 

this heater with glass doors closed. If you 

operate  heater  with  doors  closed,  heat 
buildup inside fireplace will cause glass to 

burst. Make sure there are no obstructions 

across openings of fireplace.

8.  To prevent the creation of soot, follow the 

instructions in 

Cleaning and Maintenance

page 22.

Содержание CRB3624NR

Страница 1: ...ny electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fir...

Страница 2: ...at er It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 o...

Страница 3: ...erates chemicals known to the state of California to cause cancer or birth defects or other reproduc tive harm IMPORTANT Read this owner s manual carefully and completely beforetryingtoassemble operat...

Страница 4: ...age 19 To prevent performance problems do not use propane LP fuel tank of less than 100 lb capacity propane LP units only 20 Provide adequate clearances around air openings 1 This appliance is only fo...

Страница 5: ...o not pick up heater base assem bly by burners This could damage heater Always handle base assembly by grate 2 Remove all protective packaging applied to logs and heater for shipment 3 Check all items...

Страница 6: ...ation with flue damper closed It has been tested and approved to ANSI Z21 11 2 standard for unvented heaters State and local codes in some areas prohibit the use of vent free heat ers This heater may...

Страница 7: ...m Btu Hr the space can support Example 2560 cu ft volume of space x 20 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free fireplace ____...

Страница 8: ...lhelp circulatetheheatthroughoutthe house In the event of a power outage you can use this heater as your primary heat source Figure 2 Ventilation Air from Inside Building Or Remove Door into Adjoining...

Страница 9: ...ALLATION AND CLEARANCES For Vent Free Operation WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoin ing wall MINIMUM FIREPLACE CLEARANCE TO COMB...

Страница 10: ...sured at 14 depth Figure 4 Minimum Clearance for Combustible to Wall Minimum 16 from Side Wall Example Carefully follow the instructions below This will ensure safe installation into a masonry UL127 l...

Страница 11: ...does not meet the minimum clear ances shown you must do one of the following operate logs only with the flue damper open raise the mantel to an accept able height remove the mantel Figure 6 Minimum Ma...

Страница 12: ...t Flue Opening 6 to 15 39 sq inches 15 to 30 29 sq inches Damper Damper Clamp Damper Damper Clamp Damper Figure 10 Attaching Damper Clamp Manufactured Fireplace Masonry Fireplace 14 Min Combustible Ma...

Страница 13: ...HRC200 or HRC100 Receiver and Hand Held Remote Control Kit see Accessories page 31 before installing gas log heater See installation instructions included with the kit 1 Apply pipe joint sealant ligh...

Страница 14: ...th Vent Pointing Down Installation Continued Purchase the optional CSAdesign certified equipment shutoff valve from your dealer See Accessories page 31 Minimum inlet pressure for purpose of input adju...

Страница 15: ...equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where equip ment shutoff valve was connected 3 Press...

Страница 16: ...5 11 If logs were removed from heater for in stall remote accessory replace logs see Installing Logs page 17 Installation Continued Figure 19 Disconnecting Jumper Wire From Control Valve Jumper Wire C...

Страница 17: ...l and not leaning in toward burner where the flame will touch the log 3 Position front log as shown in Figure 23 making sure the grooves in the bottom of the log fit over the grate prongs Base Assembl...

Страница 18: ...the OFF position see Figure 24 page 19 WARNING Burners will come onautomaticallywithinoneminute when the selector switch is in the ON position after the pilot is lit FOR YOUR SAFETY READ BEFORE LIGHT...

Страница 19: ...Note If pilot goes out repeat steps 4 through 8 beginning on page 18 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Wait one minute and switch selector switch to the...

Страница 20: ...de Button Locks System to Prevent Accidental Ignition Turns Burners On or Off Increases or Decreases Room Temperature in AUTO Mode Digital Display Shows Temperature and Settings MANUAL LIGHTING PROCED...

Страница 21: ...ace off This feature is not available in the MANU mode 2 The receiver continuously receives sig nals from the hand held remote to control the room temperature If the hand held remote is misplaced obst...

Страница 22: ...ater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need more frequent cleaning due to excessive lint fromcarpeting pethair b...

Страница 23: ...he unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available LOGS If you remove logs for cleaning refer to Installing Logs page 17 t...

Страница 24: ...ion 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pin...

Страница 25: ...reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 22 or replace ODS pilot a...

Страница 26: ...ave gas line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 12 4 Clean burners see Clean ing and Maintenance page 22 or replace burne...

Страница 27: ...d 1 Gas leak See Warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Hand held...

Страница 28: ...www desatech com 120044 01D 28 Parts Models CRB3624NR and CRB3624PR LPG 5 6 21 14 22 14 23 24 2 19 20 16 1 18 17 10 11 4 3 8 8 12 14 13 7 15 9 8...

Страница 29: ...101004 02 Rear Burner Injector Propane LP 1 12 101004 08 Front Burner Injector Natural 1 101004 06 Front Burner Injector Propane LP 1 13 112708 01 Remote Burner Tube 1 14 M12461 26 Screw 5 15 099918...

Страница 30: ...acement parts This will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part...

Страница 31: ...GWMS2 For all models Allows the gas log heater to be turned on and off with a wall switch VENT FREE LOGMATE FIREBOXES Available in 32 36 and 42 models Circulating fireboxes feature louvers and an opt...

Страница 32: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: