![Desa Comfort Glow LFP33NR Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/desa/comfort-glow-lfp33nr/comfort-glow-lfp33nr_owners-operation-and-installation-manual_2486328022.webp)
22
104887
UNVENTED NATURAL GAS FIREPLACE
LFP33NR
SPECIFICATIONS
LFP33NR Remote Ready
Btu (Variable)
20,000/30,000
Type Gas
Natural Gas Only
Ignition
Piezo
Pressure Manifold
3.5" W.C.
Inlet Gas Pressure (in. of water)
Maximum
10.5"
Minimum*
5"
Shipping Weight
122 lbs.
* For input adjustment
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting.
If so, contact DESA International’s Techni-
cal Service Department at 1-800-DESA LOG
(1-800-337-2564).
You can also visit DESA International’s
Technical Service web site at
www.desatech.com.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
When Gas Quality Is Bad
• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
natural gas supplier.
AUT
O
OFF
ON
Thermopile
WIRING DIAGRAM
Note
: For proper operation of optional ac-
cessories, the wires from the switch to the
control must be connected exactly as shown.