OWNER’S MANUAL

Locate the blower switch by opening lower
louver on fireplace. Blower switch is lo-
cated at lower left inside louver door.

This thermostat-controlled blower has three
settings: ON, OFF, and AUTO. In the ON
position, the blower will operate constantly.
In the OFF position, the blower will not
operate. In the AUTO position, the blower
will start when the thermostat senses a
sufficient increase in firebox temperature.

Note:

 Your gas logs and thermostat

blower will not turn on and off at the
same time. The fireplace may run for
several minutes before the blower turns
on. After the heater modulates to the pilot
position, the blower will continue to run.
The blower will shut off after the firebox
temperature decreases.

Note:

 It is safe to operate fireplace with

blower turned off. However, the blower helps
distribute heated air from the fireplace.

OPTIONAL BLOWER

OPERATION

O

FF

PILO

T

O

N

L O

I H

ON
OFF
REMOTE

Figure 38 - Setting the Selector Switch, Control Knob, and Flame
Adjustment Knob for Remote Operation

Selector Switch in Remote Position
(Optional Remote Control)

Control Knob in
On Position

Flame Adjustment Knob

 WARNING: Make sure the

selector switch is in the OFF po-
sition when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.

Ignitor Electrode

Pilot Burner

Figure 37 - Pilot

TO TURN OFF GAS

TO APPLIANCE

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 6 under Light-
ing Instructions
, page 16.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 9, page 16.

After lighting, let pilot flame burn for
about one minute. Turn control knob to
ON position. Adjust flame adjustment
knob anywhere between HI and LO. Slide
thee selector switch to the REMOTE po-
sition. 

Note:

 The burners may light if

hand-held remote ON button was on when
selector switch was last turned off. You
can now turn the burners on and off with
the hand-held remote control unit. Fol-
low the instructions supplied with the
remote control for additional features.

IMPORTANT:

 Do not leave the selector

switch in the REMOTE position when the
pilot is not lit. This will drain the battery.

NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See 

Lighting

Instructions on page 16.

OPERATING
FIREPLACE

Continued

Shutting Off Heater

1.

Turn control knob clockwise  
to the OFF position.

2a. Set selector switch in the OFF position.

2b.

If Using Optional Hand-Held Re-
mote: 

Set selector switch in the OFF

position to keep from draining battery.

Shutting Off Burners Only (pilot
stays lit)

You may shut off the burners and keep
the pilot lit by doing one of the following:

• Turn control knob clockwise  

to the PILOT position.

• Use remote control manual OFF button.

• Set selector switch in the OFF position.

OPTIONAL REMOTE

OPERATION

Thermostat Control Operation

The thermostat control setting on the
remote control unit can be set to any
comfort level between HI and LO. The
burners will turn on and off automati-
cally to maintain the comfort level you
select. The ideal comfort setting will vary
by household depending upon the amount
of space to be heated, the output of the
central heating system, etc.

Note:

 All remote control accessories must

be purchased separately (see Accessories,
pages 24 and 25). Follow instructions in-
cluded with the remote control.

IMPORTANT:

 Be sure to press the ON/

OFF buttons on the hand-held remote
control unit for up to 3 seconds to assure
proper operation.

IMPORTANT:

 The thermostat is built

into the hand-held remote. The remote
should be kept several feet from the fire-
place and should be pointed towards the
fireplace. If placed too close to the fire-
place, the remote will sense the room is
too hot and turn the fireplace off.

Содержание Comfort Glow LFP33NR

Страница 1: ...lation adjustment alteration service or maintenance can cause injury orpropertydamage Refertothis manual for correct installation and operational procedures For assistance or additional infor mation c...

Страница 2: ...eplace 7 You must operate this fireplace with the fireplace screen and hood in place Make sure fireplace screen and hood are in place before running fireplace 8 This fireplace is designed to be smoke...

Страница 3: ...e heater front Lift the heater off the bottom tray 2 Locate two screws above top corners of the fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remov...

Страница 4: ...uate combustion and ventilation air Adjoining rooms are communicating only iftherearedoorlesspassagewaysorventila tion grills between them PRODUCT FEATURES OPERATION This vent free fireplace is clean...

Страница 5: ...tu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount o...

Страница 6: ...s Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connecttheseitemsdirectlytotheoutdoo...

Страница 7: ...es of brass trim together tighten both set screws on the adjusting plate with slotted screwdriver 7 Repeat steps 1 through 6 for other side 8 Tighten trim hanging screws 10 x 6 25 shoulder into holes...

Страница 8: ...1 Assemble cabinet mantel hearth base and trim accessories Assembly instruc tions are included with each accessory 2 When installing blower install a prop erly grounded 120 volt three prong electrical...

Страница 9: ...er use dimen sions shown in Figure 13 for the rough opening The height is 33 which is the same as the wall opening above 2 If using blower install and properly ground GA3555 three prong 120 volt elect...

Страница 10: ...certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace If pipe is too small undue loss of pressure will occur Mantel Clearances for Built In...

Страница 11: ...for shipping These screws are located near top of screen Discard screws Lift fireplace screen up and pull out to remove 2 Remove screws that attach log base assembly to fireplace see Figure 17 Carefu...

Страница 12: ...or opening main gas valve located on or near gas meter 4 Check all joints of gas supply piping system Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 5 Correct all l...

Страница 13: ...cutout on the right of the middle log should fit over the burner see Fig ure 21 Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is cen tered over the...

Страница 14: ...re mote control unit following direction of arrow 2 Insert twoAAAbatteries following dia gram in battery housing area 3 Replace battery cover onto remote con trol unit Figure 30 Installing Battery in...

Страница 15: ...he battery Place battery into the battery housing 3 Replace battery cover onto remote con trol unit Figure 35 Installing Battery in Hand Held Remote Control Unit Battery Cover 9 Volt Battery Terminal...

Страница 16: ...switch to OFF position 4 Press in and turn control knob clock wise to the OFF position 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Fol...

Страница 17: ...HIandLO Slide thee selector switch to the REMOTE po sition Note The burners may light if hand heldremoteONbuttonwasonwhen selector switch was last turned off You can now turn the burners on and off wi...

Страница 18: ...eater and let cool Either remove blockage or replace burner Blocked burner flame holes will create soot CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the p...

Страница 19: ...connect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Repl...

Страница 20: ...requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe minimum...

Страница 21: ...ntilate room Stop using odor causing products while fire place is running 2 Locate and correct all leaks see Check ing Gas Connections page 12 1 Open window and or door for ventilation 2 Contact local...

Страница 22: ...ntat1 800 DESALOG 1 800 337 2564 You can also visit DESA International s Technical Service web site at www desatech com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will...

Страница 23: ...sories Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 4...

Страница 24: ...6F Series Walnut Finished Birch Veneer GMC37U Series Unfinished Birch Veneer Ready to Stain or Paint Space saving corner mantels feature mold ings fluting and medallion Dimensions H xW xD 48 3 4 x 60...

Страница 25: ...LD REMOTE CONTROL RM4 For remote control operation Installation and limited operation instructions included in this manual Extended operation instruc tions included with remote Hand held re mote contr...

Страница 26: ...UNVENTED NATURAL GAS FIREPLACE LFP33NR ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL LFP33NR 20 30 7 O F F P I L O T O N H I L O 11 15 29 10 9 7 6 5 8 12 31 17 16 28 18 19 24 14 13 22 23 22 26 27 25...

Страница 27: ...e Injector 1 11 102772 01 Burner 2 12 M11084 38 Screw 8 x 38 2 13 104236 01CK Painted Base Assy 1 14 M12461 26 Screw 10 x 32 6 15 104238 01CK Firebox Bottom 1 16 103284 03 Wiring Harness 1 17 098265 0...

Страница 28: ...28 104887 UNVENTED NATURAL GAS FIREPLACE LFP33NR ILLUSTRATED PARTS BREAKDOWN FIREPLACE LFP33NR 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13...

Страница 29: ...Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CK Firebox Wrapper 1 9 103412 01CK Louver Door 1 10 101727 02 Screen Assembly 1 11 101348 01 Firebox Support 2 12 103208 01...

Страница 30: ...ated to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OT...

Отзывы: